Regulations last checked for updates: Nov 25, 2024

Title 30 - Mineral Resources last revised: Nov 19, 2024
§ 550.1154 - How do I determine if my reservoir is sensitive?

(a) You must determine whether each reservoir is sensitive. You must classify the reservoir as sensitive if:

(1) Under initial conditions it is an oil reservoir with an associated gas cap;

(2) At any time there are near-critical fluids; or

(3) The reservoir is undergoing enhanced recovery.

(b) For the purposes of this subpart, near-critical fluids are:

(1) Those fluids that occur in high temperature, high-pressure reservoirs where it is not possible to define the liquid-gas contact; or

(2) Fluids in reservoirs that are near bubble point or dew point conditions.

(c) The Regional Supervisor may reclassify a reservoir when available information warrants reclassification.

(d) If available information indicates that a reservoir previously classified as non-sensitive is now sensitive, you must submit a request to the Regional Supervisor to reclassify the reservoir. You must include supporting information, as listed in the table in § 550.1167, with your request.

(e) If information indicates that a reservoir previously classified as sensitive is now non-sensitive, you may submit a request to the Regional Supervisor to reclassify the reservoir. You must include supporting information, as listed in the table in § 550.1167, with your request.

authority: 25 U.S.C. 3001
source: 76 FR 64623, Oct. 18, 2011, unless otherwise noted.
cite as: 30 CFR 550.1154