Regulations last checked for updates: Nov 22, 2024

Title 46 - Shipping last revised: Nov 04, 2024
§ 154.451 - Design vapor pressure.

The Po (kPa) of an independent tank type C must be calculated by the following formula:

Po = 196 + AC(ρ) 3/2 where: A = 1.813 (σm/ΔσA) 2; σm = design primary membrane stress; ΔσA = (allowable dynamic membrane stress for double amplitude at probability level Q = 10−8) 53.9 MPa (7821 psi) for ferritic and martensitic steels and 24.5 MPa (3555 psi) for 5083-0 aluminum; C = a characteristic tank dimension that is the greatest of h, 0.75b, or 0.45 l; where: h = the height of the tank or the dimension in the vessel's vertical direction, in meters; b = the width of the tank or the dimension in the vessel's transverse direction; in meters; and l = the length of the tank or the dimension in the vessel's longitudinal direction, in meters; and ρ = the specific gravity of the cargo.
authority: 46 U.S.C. 3703,9101; Department of Homeland Security Delegation No. 0170.1
source: CGD 74-289, 44 FR 26009, May 3, 1979, unless otherwise noted.
cite as: 46 CFR 154.451