Regulations last checked for updates: Oct 17, 2024

Title 49 - Transportation last revised: Oct 15, 2024
§ 192.113 - Longitudinal joint factor (E) for steel pipe.

(a) The longitudinal joint factor to be used in the design formula in § 192.105 is determined in accordance with the table 1 to this paragraph (a):

Table 1 to Paragraph (a)

Specification Pipe class Longitudinal
joint factor
(E)
ASTM A53/A53M (incorporated by reference, see § 192.7)Seamless1.00
Electric resistance welded1.00
Furnace butt welded.60
ASTM A106/A106M (incorporated by reference, see § 192.7)Seamless1.00
ASTM A333/A333M (incorporated by reference, see § 192.7)Seamless1.00
Electric resistance welded1.00
ASTM A381 (incorporated by reference, see § 192.7)Double submerged arc welded1.00
ASTM A671/A671M (incorporated by reference, see § 192.7)Electric-fusion-welded1.00
ASTM A672 (incorporated by reference, see § 192.7)Electric-fusion-welded1.00
ASTM A691/A691M (incorporated by reference, see § 192.7)Electric-fusion-welded1.00
API Spec 5L (incorporated by reference, see § 192.7)Seamless1.00
Electric resistance welded1.00
Electric flash welded1.00
Submerged arc welded1.00
Furnace butt welded.60
OtherPipe over 4 inches (102 millimeters).80
OtherPipe 4 inches (102 millimeters) or less.60

(b) If the type of longitudinal joint cannot be determined, the joint factor to be used must not exceed that designated for “Other.”

[Amdts. 192-135, 195-107, 89 FR 33280, Apr. 29, 2024]
authority: 30 U.S.C. 185(w)(3), 49 U.S.C. 5103,60101
source: 35 FR 13257, Aug. 19, 1970, unless otherwise noted.