Regulations last checked for updates: Nov 23, 2024
Title 27 - Alcohol, Tobacco Products and Firearms last revised: Nov 15, 2024
§ 555.201 - General.
(a) Section 842(j) of the Act and § 555.29 of this part require that the storage of explosive materials by any person must be in accordance with the regulations in this part. Further, section 846 of this Act authorizes regulations to prevent the recurrence of accidental explosions in which explosive materials were involved. The storage standards prescribed by this subpart confer no right or privileges to store explosive materials in a manner contrary to State or local law.
(b) The Director may authorize alternate construction for explosives storage magazines when it is shown that the alternate magazine construction is substantially equivalent to the standards of safety and security contained in this subpart. Any alternate explosive magazine construction approved by the Director prior to August 9, 1982, will continue as approved unless notified in writing by the Director. Any person intending to use alternate magazine construction shall submit a letter application to the Director, Industry Operations for transmittal to the Director, specifically describing the proposed magazine. Explosive materials may not be stored in alternate magazines before the applicant has been notified that the application has been approved.
(c) A licensee or permittee who intends to make changes in his magazines, or who intends to construct or acquire additional magazines, shall comply with § 555.63.
(d) The regulations set forth in §§ 555.221 through 555.224 pertain to the storage of display fireworks, pyrotechnic compositions, and explosive materials used in assembling fireworks and articles pyrotechnic.
(e) [Reserved]
(f) Any person who stores explosive materials shall notify the authority having jurisdiction for fire safety in the locality in which the explosive materials are being stored of the type, magazine capacity, and location of each site where such explosive materials are stored. Such notification shall be made orally before the end of the day on which storage of the explosive materials commenced and in writing within 48 hours from the time such storage commenced.
(Paragraph (f) approved by the Office of Management and Budget under control number 1140-0071)
[T.D. ATF-87, 46 FR 40384, Aug. 7, 1981, as amended by T.D. ATF-293, 55 FR 3722, Feb. 5, 1990; T.D. ATF-400, 63 FR 45003, Aug. 24, 1998; ATF-11F, 73 FR 57242, Oct. 2, 2008; ATF 2013R-9F, 79 FR 46694, Aug. 11, 2014; ATF 2017R-21, 84 FR 13800, Apr. 8, 2019]
§ 555.202 - Classes of explosive materials.
For purposes of this part, there are three classes of explosive materials. These classes, together with the description of explosive materials comprising each class, are as follows:
(a) High explosives. Explosive materials which can be caused to detonate by means of a blasting cap when unconfined, (for example, dynamite, flash powders, and bulk salutes).
(b) Low explosives. Explosive materials which can be caused to deflagrate when confined (for example, black powder, safety fuses, igniters, igniter cords, fuse lighters, and “display fireworks” classified as UN0333, UN0334, or UN0335 by the U.S. Department of Transportation regulations at 49 CFR 172.101, except for bulk salutes).
(c) Blasting agents. (For example, ammonium nitrate-fuel oil and certain water-gels (see also § 555.11).
[T.D. ATF-87, 46 FR 40384, Aug. 7, 1981, as amended by T.D. ATF-293, 55 FR 3722, Feb. 5, 1990; T.D. ATF-400, 63 FR 45003, Aug. 24, 1998; ATF 2017R-21, 84 FR 13800, Apr. 8, 2019]
§ 555.203 - Types of magazines.
For purposes of this part, there are five types of magazines. These types, together with the classes of explosive materials, as defined in § 555.202, which will be stored in them, are as follows:
(a) Type 1 magazines. Permanent magazines for the storage of high explosives, subject to the limitations prescribed by §§ 555.206 and 555.213. Other classes of explosive materials may also be stored in type 1 magazines.
(b) Type 2 magazines. Mobile and portable indoor and outdoor magazines for the storage of high explosives, subject to the limitations prescribed by §§ 555.206, 555.208(b), and 555.213. Other classes of explosive materials may also be stored in type 2 magazines.
(c) Type 3 magazines. Portable outdoor magazines for the temporary storage of high explosives while attended (for example, a “day-box”), subject to the limitations prescribed by §§ 555.206 and 555.213. Other classes of explosives materials may also be stored in type 3 magazines.
(d) Type 4 magazines. Magazines for the storage of low explosives, subject to the limitations prescribed by §§ 555.206(b), 555.210(b), and 555.213. Blasting agents may be stored in type 4 magazines, subject to the limitations prescribed by §§ 555.206(c), 555.211(b), and 555.213. Detonators that will not mass detonate may also be stored in type 4 magazines, subject to the limitations prescribed by §§ 555.206(a), 555.210(b), and 555.213.
(e) Type 5 magazines. Magazines for the storage of blasting agents, subject to the limitations prescribed by §§ 555.206(c), 555.211(b), and 555.213.
§ 555.204 - Inspection of magazines.
Any person storing explosive materials shall inspect his magazines at least every seven days. This inspection need not be an inventory, but must be sufficient to determine whether there has been unauthorized entry or attempted entry into the magazines, or unauthorized removal of the contents of the magazines.
§ 555.205 - Movement of explosive materials.
All explosive materials must be kept in locked magazines meeting the standards in this subpart unless they are:
(a) In the process of manufacture;
(b) Being physically handled in the operating process of a licensee or user;
(c) Being used; or
(d) Being transported to a place of storage or use by a licensee or permittee or by a person who has lawfully acquired explosive materials under § 555.106.
§ 555.206 - Location of magazines.
(a) Outdoor magazines in which high explosives are stored must be located no closer to inhabited buildings, passenger railways, public highways, or other magazines in which high explosives are stored, than the minimum distances specified in the table of distances for storage of explosive materials in § 555.218.
(b) Outdoor magazines in which low explosives are stored must be located no closer to inhibited buildings, passenger railways, public highways, or other magazines in which explosive materials are stored, than the minimum distances specified in the table of distances for storage of low explosives in § 555.219, except that the table of distances in § 555.224 shall apply to the storage of display fireworks. The distances shown in § 555.219 may not be reduced by the presence of barricades.
(c)(1) Outdoor magazines in which blasting agents in quantities of more than 50 pounds are stored must be located no closer to inhabited buildings, passenger railways, or public highways than the minimum distances specified in the table of distances for storage of explosive materials in § 555.218.
(2) Ammonium nitrate and magazines in which blasting agents are stored must be located no closer to magazines in which high explosives or other blasting agents are stored than the minimum distances specified in the table of distances for the separation of ammonium nitrate and blasting agents in § 555.220. However, the minimum distances for magazines in which explosives and blasting agents are stored from inhabited buildings, etc., may not be less than the distances specified in the table of distances for storage of explosives materials in § 555.218.
[T.D. ATF-87, 46 FR 40384, Aug. 7, 1981, as amended by T.D. ATF-293, 55 FR 3722, Feb. 5, 1990; T.D. ATF-400, 63 FR 45003, Aug. 24, 1998]
§ 555.207 - Construction of type 1 magazines.
A type 1 magazine is a permanent structure: a building, an igloo or “Army-type structure”, a tunnel, or a dugout. It is to be bullet-resistant, fire-resistant, weather-resistant, theft-resistant, and ventilated.
(a) Buildings. All building type magazines are to be constructed of masonry, wood, metal, or a combination of these materials, and have no openings except for entrances and ventilation. The ground around building magazines must slope away for drainage or other adequate drainage provided.
(1) Masonry wall construction. Masonry wall construction is to consist of brick, concrete, tile, cement block, or cinder block and be not less than 6 inches in thickness. Hollow masonry units used in construction must have all hollow spaces filled with well-tamped, coarse, dry sand or weak concrete (at least a mixture of one part cement and eight parts of sand with enough water to dampen the mixture while tamping in place). Interior walls are to be constructed of, or covered with, a nonsparking material.
(2) Fabricated metal wall construction. Metal wall construction is to consist of sectional sheets of steel or aluminum not less than number 14-gauge, securely fastened to a metal framework. Metal wall construction is either lined inside with brick, solid cement blocks, hardwood not less than four inches thick, or will have at least a six inch sand fill between interior and exterior walls. Interior walls are to be constructed of, or covered with, a nonsparking material.
(3) Wood frame wall construction. The exterior of outer wood walls is to be covered with iron or aluminum not less than number 26-gauge. An inner wall of, or covered with nonsparking material will be constructed so as to provide a space of not less than six inches between the outer and inner walls. The space is to be filled with coarse, dry sand or weak concrete.
(4) Floors. Floors are to be constructed of, or covered with, a nonsparking material and shall be strong enough to bear the weight of the maximum quantity to be stored. Use of pallets covered with a nonsparking material is considered equivalent to a floor constructed of or covered with a nonsparking material.
(5) Foundations. Foundations are to be constructed of brick, concrete, cement block, stone, or wood posts. If piers or posts are used, in lieu of a continuous foundation, the space under the buildings is to be enclosed with metal.
(6) Roof. Except for buildings with fabricated metal roofs, the outer roof is to be covered with no less than number 26-guage iron or aluminum, fastened to at least
7/8 inch sheathing.
(7) Bullet-resistant ceilings or roofs. Where it is possible for a bullet to be fired directly through the roof and into the magazine at such an angle that the bullet would strike the explosives within, the magazine is to be protected by one of the following methods:
(i) A sand tray lined with a layer of building paper, plastic, or other nonporous material, and filled with not less than four inches of coarse, dry sand, and located at the tops of inner walls covering the entire ceiling area, except that portion necessary for ventilation.
(ii) A fabricated metal roof constructed of
3/16-inch plate steel lined with four inches of hardwood. (For each additional
1/16 inch of plate steel, the hardwood lining may be decreased one inch.)
(8) Doors. All doors are to be constructed of not less than
1/4 inch plate steel and lined with at least two inches of hardwood. Hinges and hasps are to be attached to the doors by welding, riveting or bolting (nuts on inside of door). They are to be installed in such a manner that the hinges and hasps cannot be removed when the doors are closed and locked.
(9) Locks. Each door is to be equipped with (i) two mortise locks; (ii) two padlock fastened in separate hasps and staples; (iii) a combination of a mortise lock and a padlock; (iv) a mortise lock that requires two keys to open; or (v) a three-point lock. Padlocks must have at least five tumblers and a casehardened shackle of at least
3/8 inch diameter. Padlocks must be protected with not less than
1/4 inch steel hoods constructed so as to prevent sawing or lever action on the locks, hasps, and staples. These requirements do not apply to magazine doors that are adequately secured on the inside by means of a bolt, lock, or bar that cannot be actuated from the outside.
(10) Ventilation. Ventilation is to be provided to prevent dampness and heating of stored explosive materials. Ventilation openings must be screened to prevent the entrance of sparks. Ventilation openings in side walls and foundations must be offset or shielded for bullet-resistant purposes. Magazines having foundation and roof ventilators with the air circulating between the side walls and the floors and between the side walls and the ceiling must have a wooden lattice lining or equivalent to prevent the packages of explosive materials from being stacked against the side walls and blocking the air circulation.
(11) Exposed metal. No sparking material is to be exposed to contact with the stored explosive materials. All ferrous metal nails in the floor and side walls, which might be exposed to contact with explosive materials, must be blind nailed, countersunk, or covered with a nonsparking lattice work or other nonsparking material.
(b) Igloos, “Army-type structures”, tunnels, and dugouts. Igloo, “Army-type structure”, tunnel, and dugout magazines are to be constructed of reinforced concrete, masonry, metal, or a combination of these materials. They must have an earthmound covering of not less than 24 inches on the top, sides and rear unless the magazine meets the requirements of paragraph (a)(7) of this section. Interior walls and floors must be constructed of, or covered with, a nonsparking material. Magazines of this type are also to be constructed in conformity with the requirements of paragraph (a)(4) and paragraphs (a)(8) through (11) of this section.
§ 555.208 - Construction of type 2 magazines.
A type 2 magazine is a box, trailer, semitrailer, or other mobile facility.
(a) Outdoor magazines—(1) General. Outdoor magazines are to be bullet-resistant, fire-resistant, weather-resistant, theft-resistant, and ventilated. They are to be supported to prevent direct contact with the ground and, if less than one cubic yard in size, must be securely fastened to a fixed object. The ground around outdoor magazines must slope away for drainage or other adequate drainage provided. When unattended, vehicular magazines must have wheels removed or otherwise effectively immobilized by kingpin locking devices or other methods approved by the Director.
(2) Exterior construction. The exterior and doors are to be constructed of not less than
1/4-inch steel and lined with at least two inches of hardwood. Magazines with top openings will have lids with water-resistant seals or which overlap the sides by at least one inch when in a closed position.
(3) Hinges and hasps. Hinges and hasps are to be attached to doors by welding, riveting, or bolting (nuts on inside of door). Hinges and hasps must be installed so that they cannot be removed when the doors are closed and locked.
(4) Locks. Each door is to be equipped with (i) two mortise locks; (ii) two padlocks fastened in separate hasps and staples; (iii) a combination of a mortise lock and a padlock; (iv) a mortise lock that requires two keys to open; or (v) a three-point lock. Padlocks must have at least five tumblers and a case-hardened shackle of at least
3/8-inch diameter. Padlocks must be protected with not less than
1/4-inch steel hoods constructed so as to prevent sawing or lever action on the locks, hasps, and staples. These requirements do not apply to magazine doors that are adequately secured on the inside by means of a bolt, lock, or bar that cannot be actuated from the outside.
(b) Indoor magazines—(1) General. Indoor magazines are to be fire-resistant and theft-resistant. They need not be bullet-resistant and weather-resistant if the buildings in which they are stored provide protection from the weather and from bullet penetration. No indoor magazine is to be located in a residence or dwelling. The indoor storage of high explosives must not exceed a quantity of 50 pounds. More than one indoor magazine may be located in the same building if the total quantity of explosive materials stored does not exceed 50 pounds. Detonators must be stored in a separate magazine (except as provided in § 555.213) and the total quantity of detonators must not exceed 5,000.
(2) Exterior construction. Indoor magazines are to be constructed of wood or metal according to one of the following specifications:
(i) Wood indoor magazines are to have sides, bottoms and doors constructed of at least two inches of hardwood and are to be well braced at the corners. They are to be covered with sheet metal of not less than number 26-gauge (.0179 inches). Nails exposed to the interior of magazines must be countersunk.
(ii) Metal indoor magazines are to have sides, bottoms and doors constructed of not less than number 12-gauge (.1046 inches) metal and be lined inside with a nonsparking material. Edges of metal covers must overlap sides at least one inch.
(3) Hinges and hasps. Hinges and hasps are to be attached to doors by welding, riveting, or bolting (nuts on inside of door). Hinges and hasps must be installed so that they cannot be removed when the doors are closed and locked.
(4) Locks. Each door is to be equipped with (i) two mortise locks; (ii) two padlocks fastened in separate hasps and staples; (iii) a combination of a mortise lock and a padlock; (iv) a mortise lock that requires two keys to open; or (v) a three-point lock. Padlocks must have at least five tumblers and a case-hardened shackle of at least
3/8-inch diameter. Padlocks must be protected with not less than
1/4-inch steel hoods constructed so as to prevent sawing or lever action on the locks, hasps, and staples. Indoor magazines located in secure rooms that are locked as provided in this subparagraph may have each door locked with one steel padlock (which need not be protected by a steel hood) having at least five tumblers and a case-hardened shackle of at least
3/8-inch diameter, if the door hinges and lock hasp are securely fastened to the magazine. These requirements do not apply to magazine doors that are adequately secured on the inside by means of a bolt, lock, or bar that cannot be actuated from the outside.
(c) Detonator boxes. Magazines for detonators in quantities of 100 or less are to have sides, bottoms and doors constructed of not less than number 12-gauge (.1046 inches) metal and lined with a nonsparking material. Hinges and hasps must be attached so they cannot be removed from the outside. One steel padlock (which need not be protected by a steel hood) having at least five tumblers and a case-hardened shackle of at least
3/8-inch diameter is sufficient for locking purposes.
§ 555.209 - Construction of type 3 magazines.
A type 3 magazine is a “day-box” or other portable magazine. It must be fire-resistant, weather-resistant, and theft-resistant. A type 3 magazine is to be constructed of not less than number 12-gauge (.1046 inches) steel, lined with at least either
1/2-inch plywood or
1/2-inch Masonite-type hardboard. Doors must overlap sides by at least one inch. Hinges and hasps are to be attached by welding, riveting or bolting (nuts on inside). One steel padlock (which need not be protected by a steel hood) having at least five tumblers and a case-hardened shackle of at least
3/8-inch diameter is sufficient for locking purposes. Explosive materials are not to be left unattended in type 3 magazines and must be removed to type 1 or 2 magazines for unattended storage.
§ 555.210 - Construction of type 4 magazines.
A type 4 magazine is a building, igloo or “Army-type structure”, tunnel, dugout, box, trailer, or a semitrailer or other mobile magazine.
(a) Outdoor magazines—(1) General. Outdoor magazines are to be fire-resistant, weather-resistant, and theft-resistant. The ground around outdoor magazines must slope away for drainage or other adequate drainage be provided. When unattended, vehicular magazines must have wheels removed or otherwise be effectively immobilized by kingpin locking devices or other methods approved by the Director.
(2) Construction. Outdoor magazines are to be constructed of masonry, metal-covered wood, fabricated metal, or a combination of these materials. Foundations are to be constructed of brick, concrete, cement block, stone, or metal or wood posts. If piers or posts are used, in lieu of a continuous foundation, the space under the building is to be enclosed with fire-resistant material. The walls and floors are to be constructed of, or covered with, a nonsparking material or lattice work. The doors must be metal or solid wood covered with metal.
(3) Hinges and hasps. Hinges and hasps are to be attached to doors by welding, riveting, or bolting (nuts on inside of door). Hinges and hasps must be installed so that they cannot be removed when the doors are closed and locked.
(4) Locks. Each door is to be equipped with (i) two mortise locks; (ii) two padlocks fastened in separate hasps and staples; (iii) a combination of a mortise lock and a padlock; (iv) a mortise lock that requires two keys to open; or (v) a three-point lock. Padlocks must have at least five tumblers and case-hardened shackle of at least
3/8 inch diameter. Padlocks must be protected with not less than
1/4 inch steel hoods constructed so as to prevent sawing or lever action on the locks, hasps, and staples. These requirements do not apply to magazine doors that are adequately secured on the inside by means of a bolt, lock, or bar that cannot be actuated from the outside.
(b) Indoor magazine—(1) General. Indoor magazines are to be fire-resistant and theft-resistant. They need not be weather-resistant if the buildings in which they are stored provide protection from the weather. No indoor magazine is to be located in a residence or dwelling. The indoor storage of low explosives must not exceed a quantity of 50 pounds. More than one indoor magazine may be located in the same building if the total quantity of explosive materials stored does not exceed 50 pounds. Detonators that will not mass detonate must be stored in a separate magazine and the total number of electric detonators must not exceed 5,000.
(2) Construction. Indoor magazines are to be constructed of masonry, metal-covered wood, fabricated metal, or a combination of these materials. The walls and floors are to be constructed of, or covered with, a nonsparking material. The doors must be metal or solid wood covered with metal.
(3) Hinges and hasps. Hinges and hasps are to be attached to doors by welding, riveting, or bolting (nuts on inside of door). Hinges and hasps must be installed so that they cannot be removed when the doors are closed and locked.
(4) Locks. Each door is to be equipped with (i) two mortise locks; (ii) two padlocks fastened in separate hasps and staples; (iii) a combination of a mortise lock and padlock; (iv) a mortise lock that requires two keys to open; or (v) a three-point lock. Padlocks must have at least five tumblers and a case-hardened shackle of at least
3/8 inch diameter. Padlocks must be protected with not less than
1/4 inch steel hoods constructed so as to prevent sawing or lever action on the locks, hasps, and staples. Indoor magazines located in secure rooms that are locked as provided in this subparagraph may have each door locked with one steel padlock (which need not be protected by a steel hood) having at least five tumblers and a case-hardened shackle of at least
3/8 inch diameter, if the door hinges and lock hasp are securely fastened to the magazine. These requirements do not apply to magazine doors that are adequately secured on the inside by means of a bolt, lock, or bar that cannot be actuated from the outside.
§ 555.211 - Construction of type 5 magazines.
A type 5 magazine is a building, igloo or “Army-type structure”, tunnel, dugout, bin, box, trailer, or a semitrailer or other mobile facility.
(a) Outdoor magazines—(1) General. Outdoor magazines are to be weather-resistant and theft-resistant. The ground around magazines must slope away for drainage or other adequate drainage be provided. When unattended, vehicular magazines must have wheels removed or otherwise be effectively immobilized by kingpin locking devices or other methods approved by the Director.
(2) Construction. The doors are to be constructed of solid wood or metal.
(3) Hinges and hasps. Hinges and hasps are to be attached to doors by welding, riveting, or bolting (nuts on inside of door). Hinges and hasps must be installed so that they cannot be removed when the doors are closed and locked.
(4) Locks. Each door is to be equipped with (i) two mortise locks; (ii) two padlocks fastened in separate hasps and staples; (iii) a combination of a mortise lock and a padlock; (iv) a mortise lock that requires two keys to open; or (v) a three-point lock. Padlocks must have at least five tumblers and a case-hardened shackle of at least
3/8 inch diameter. Padlocks must be protected with not less than
1/4 inch steel hoods constructed so as to prevent sawing or lever action on the locks, hasps, and staples. Trailers, semitrailers, and similar vehicular magazines may, for each door, be locked with one steel padlock (which need not be protected by a steel hood) having at least five tumblers and a case-hardened shackle of at least
3/8 inch diameter, if the door hinges and lock hasp are securely fastened to the magazine and to the door frame. These requirements do not apply to magazine doors that are adequately secured on the inside by means of a bolt, lock, or bar that cannot be actuated from the outside.
(5) Placards. The placards required by Department of Transportation regulations at 49 CFR part 172, subpart F, for the transportation of blasting agents shall be displayed on all magazines.
(b) Indoor magazines—(1) General. Indoor magazines are to be theft-resistant. They need not be weather-resistant if the buildings in which they are stored provide protection from the weather. No indoor magazine is to be located in a residence or dwelling. Indoor magazines containing quantities of blasting agents in excess of 50 pounds are subject to the requirements of § 555.206 of this subpart.
(2) Construction. The doors are to be constructed of wood or metal.
(3) Hinges and hasps. Hinges and hasps are to be attached to doors by welding, riveting, or bolting (nuts on inside). Hinges and hasps must be installed so that they cannot be removed when the doors are closed and locked.
(4) Locks. Each door is to be equipped with (i) two mortise locks; (ii) two padlocks fastened in separate hasps and staples; (iii) a combination of a mortise lock and a padlock; (iv) a mortise lock that requires two keys to open; or (v) a three-point lock. Padlocks must have at least five tumblers and a case-hardened shackle of at least
3/8 inch diameter. Padlocks must be protected with not less than
1/4 inch steel hoods constructed so as to prevent sawing or lever action on the locks, hasps, and staples. Indoor magazines located in secure rooms that are locked as provided in this subparagraph may have each door locked with one steel padlock (which need not be protected by a steel hood) having at least five tumblers and a case-hardened shackle of at least
3/8 inch diameter, if the door hinges and lock hasps are securely fastened to the magazine and to the door frame. These requirements do not apply to magazine doors that are adequately secured on the inside by means of a bolt, lock, or bar that cannot be actuated from the outside.
[T.D. ATF-87, 46 FR 40384, Aug. 7, 1981, as amended by T.D. ATF-298, 55 FR 21863, May 30, 1990]
§ 555.212 - Smoking and open flames.
Smoking, matches, open flames, and spark producing devices are not permitted:
(a) In any magazine;
(b) Within 50 feet of any outdoor magazine; or
(c) Within any room containing an indoor magazine.
§ 555.213 - Quantity and storage restrictions.
(a) Explosive materials in excess of 300,000 pounds or detonators in excess of 20 million are not to be stored in one magazine unless approved by the Director.
(b) Detonators are not to be stored in the same magazine with other explosive materials, except under the following circumstances:
(1) In a type 4 magazine, detonators that will not mass detonate may be stored with electric squibs, safety fuse, shock tube, igniters, and igniter cord.
(2) In a type 1 or type 2 magazine, detonators may be stored with delay devices and any of the items listed in paragraph (b)(1) of this section.
[T.D. ATF-487, 68 FR 3748, Jan. 24, 2003, as amended by ATF 15F, 75 FR 3163, Jan. 20, 2010]
§ 555.214 - Storage within types 1, 2, 3, and 4 magazines.
(a) Explosive materials within a magazine are not to be placed directly against interior walls and must be stored so as not to interfere with ventilation. To prevent contact of stored explosive materials with walls, a nonsparking lattice work or other nonsparking material may be used.
(b) Containers of explosive materials are to be stored so that marks are visible. Stocks of explosive materials are to be stored so they can be easily counted and checked upon inspection.
(c) Except with respect to fiberboard or other nonmetal containers, containers of explosive materials are not to be unpacked or repacked inside a magazine or within 50 feet of a magazine, and must not be unpacked or repacked close to other explosive materials. Containers of explosive materials must be closed while being stored.
(d) Tools used for opening or closing containers of explosive materials are to be of nonsparking materials, except that metal slitters may be used for opening fiberboard containers. A wood wedge and a fiber, rubber, or wooden mallet are to be used for opening or closing wood containers of explosive materials. Metal tools other than nonsparking transfer conveyors are not to be stored in any magazine containing high explosives.
§ 555.215 - Housekeeping.
Magazines are to be kept clean, dry, and free of grit, paper, empty packages and containers, and rubbish. Floors are to be regularly swept. Brooms and other utensils used in the cleaning and maintenance of magazines must have no spark-producing metal parts, and may be kept in magazines. Floors stained by leakage from explosive materials are to be cleaned according to instructions of the explosives manufacturer. When any explosive material has deteriorated it is to be destroyed in accordance with the advice or instructions of the manufacturer. The area surrounding magazines is to be kept clear of rubbish, brush, dry grass, or trees (except live trees more than 10 feet tall), for not less than 25 feet in all directions. Volatile materials are to be kept a distance of not less than 50 feet from outdoor magazines. Living foliage which is used to stabilize the earthen covering of a magazine need not be removed.
§ 555.216 - Repair of magazines.
Before repairing the interior of magazines, all explosive materials are to be removed and the interior cleaned. Before repairing the exterior of magazines, all explosive materials must be removed if there exists any possibility that repairs may produce sparks or flame. Explosive materials removed from magazines under repair must be (a) placed in other magazines appropriate for the storage of those explosive materials under this subpart, or (b) placed a safe distance from the magazines under repair where they are to be properly guarded and protected until the repairs have been completed.
§ 555.217 - Lighting.
(a) Battery-activated safety lights or battery-activated safety lanterns may be used in explosives storage magazines.
(b) Electric lighting used in any explosives storage magazine must meet the standards prescribed by the “National Electrical Code,” (National Fire Protection Association, NFPA 70-81), for the conditions present in the magazine at any time. All electrical switches are to be located outside of the magazine and also meet the standards prescribed by the National Electrical Code.
(c) Copies of invoices, work orders or similar documents which indicate the lighting complies with the National Electrical Code must be available for inspection by ATF officers.
§ 555.218 - Table of distances for storage of explosive materials.
Quantity of explosives
| Distances in feet
|
---|
Pounds over
| Pounds not over
| Inhabited buildings
| Public highways with traffic volume of 3000 or fewer vehicles/day
| Passenger railways—public highways with traffic volume of more than 3,000 vehicles/day
| Separation of magazines
|
---|
Barricaded
| Unbarricaded
| Barricaded
| Unbarricaded
| Barricaded
| Unbarricaded
| Barricaded
| Unbarricaded
|
---|
0 | 5 | 70 | 140 | 30 | 60 | 51 | 102 | 6 | 12
|
5 | 10 | 90 | 180 | 35 | 70 | 64 | 128 | 8 | 16
|
10 | 20 | 110 | 220 | 45 | 90 | 81 | 162 | 10 | 20
|
20 | 30 | 125 | 250 | 50 | 100 | 93 | 186 | 11 | 22
|
30 | 40 | 140 | 280 | 55 | 110 | 103 | 206 | 12 | 24
|
40 | 50 | 150 | 300 | 60 | 120 | 110 | 220 | 14 | 28
|
50 | 75 | 170 | 340 | 70 | 140 | 127 | 254 | 15 | 30
|
75 | 100 | 190 | 380 | 75 | 150 | 139 | 278 | 16 | 32
|
100 | 125 | 200 | 400 | 80 | 160 | 150 | 300 | 18 | 36
|
125 | 150 | 215 | 430 | 85 | 170 | 159 | 318 | 19 | 38
|
150 | 200 | 235 | 470 | 95 | 190 | 175 | 350 | 21 | 42
|
200 | 250 | 255 | 510 | 105 | 210 | 189 | 378 | 23 | 46
|
250 | 300 | 270 | 540 | 110 | 220 | 201 | 402 | 24 | 48
|
300 | 400 | 295 | 590 | 120 | 240 | 221 | 442 | 27 | 54
|
400 | 500 | 320 | 640 | 130 | 260 | 238 | 476 | 29 | 58
|
500 | 600 | 340 | 680 | 135 | 270 | 253 | 506 | 31 | 62
|
600 | 700 | 355 | 710 | 145 | 290 | 266 | 532 | 32 | 64
|
700 | 800 | 375 | 750 | 150 | 300 | 278 | 556 | 33 | 66
|
800 | 900 | 390 | 780 | 155 | 310 | 289 | 578 | 35 | 70
|
900 | 1,000 | 400 | 800 | 160 | 320 | 300 | 600 | 36 | 72
|
1,000 | 1,200 | 425 | 850 | 165 | 330 | 318 | 636 | 39 | 78
|
1,200 | 1,400 | 450 | 900 | 170 | 340 | 336 | 672 | 41 | 82
|
1,400 | 1,600 | 470 | 940 | 175 | 350 | 351 | 702 | 43 | 86
|
1,600 | 1,800 | 490 | 980 | 180 | 360 | 366 | 732 | 44 | 88
|
1,800 | 2,000 | 505 | 1,010 | 185 | 370 | 378 | 756 | 45 | 90
|
2,000 | 2,500 | 545 | 1,090 | 190 | 380 | 408 | 816 | 49 | 98
|
2,500 | 3,000 | 580 | 1,160 | 195 | 390 | 432 | 864 | 52 | 104
|
3,000 | 4,000 | 635 | 1,270 | 210 | 420 | 474 | 948 | 58 | 116
|
4,000 | 5,000 | 685 | 1,370 | 225 | 450 | 513 | 1,026 | 61 | 122
|
5,000 | 6,000 | 730 | 1,460 | 235 | 470 | 546 | 1,092 | 65 | 130
|
6,000 | 7,000 | 770 | 1,540 | 245 | 490 | 573 | 1,146 | 68 | 136
|
7,000 | 8,000 | 800 | 1,600 | 250 | 500 | 600 | 1,200 | 72 | 144
|
8,000 | 9,000 | 835 | 1,670 | 255 | 510 | 624 | 1,248 | 75 | 150
|
9,000 | 10,000 | 865 | 1,730 | 260 | 520 | 645 | 1,290 | 78 | 156
|
10,000 | 12,000 | 875 | 1,750 | 270 | 540 | 687 | 1,374 | 82 | 164
|
12,000 | 14,000 | 885 | 1,770 | 275 | 550 | 723 | 1,446 | 87 | 174
|
14,000 | 16,000 | 900 | 1,800 | 280 | 560 | 756 | 1,512 | 90 | 180
|
16,000 | 18,000 | 940 | 1,880 | 285 | 570 | 786 | 1,572 | 94 | 188
|
18,000 | 20,000 | 975 | 1,950 | 290 | 580 | 813 | 1,626 | 98 | 196
|
20,000 | 25,000 | 1,055 | 2,000 | 315 | 630 | 876 | 1,752 | 105 | 210
|
25,000 | 30,000 | 1,130 | 2,000 | 340 | 680 | 933 | 1,866 | 112 | 224
|
30,000 | 35,000 | 1,205 | 2,000 | 360 | 720 | 981 | 1,962 | 119 | 238
|
35,000 | 40,000 | 1,275 | 2,000 | 380 | 760 | 1,026 | 2,000 | 124 | 248
|
40,000 | 45,000 | 1,340 | 2,000 | 400 | 800 | 1,068 | 2,000 | 129 | 258
|
45,000 | 50,000 | 1,400 | 2,000 | 420 | 840 | 1,104 | 2,000 | 135 | 270
|
50,000 | 55,000 | 1,460 | 2,000 | 440 | 880 | 1,140 | 2,000 | 140 | 280
|
55,000 | 60,000 | 1,515 | 2,000 | 455 | 910 | 1,173 | 2,000 | 145 | 290
|
60,000 | 65,000 | 1,565 | 2,000 | 470 | 940 | 1,206 | 2,000 | 150 | 300
|
65,000 | 70,000 | 1,610 | 2,000 | 485 | 970 | 1,236 | 2,000 | 155 | 310
|
70,000 | 75,000 | 1,655 | 2,000 | 500 | 1,000 | 1,263 | 2,000 | 160 | 320
|
75,000 | 80,000 | 1,695 | 2,000 | 510 | 1,020 | 1,293 | 2,000 | 165 | 330
|
80,000 | 85,000 | 1,730 | 2,000 | 520 | 1,040 | 1,317 | 2,000 | 170 | 340
|
85,000 | 90,000 | 1,760 | 2,000 | 530 | 1,060 | 1,344 | 2,000 | 175 | 350
|
90,000 | 95,000 | 1,790 | 2,000 | 540 | 1,080 | 1,368 | 2,000 | 180 | 360
|
95,000 | 100,000 | 1,815 | 2,000 | 545 | 1,090 | 1,392 | 2,000 | 185 | 370
|
100,000 | 110,000 | 1,835 | 2,000 | 550 | 1,100 | 1,437 | 2,000 | 195 | 390
|
110,000 | 120,000 | 1,855 | 2,000 | 555 | 1,110 | 1,479 | 2,000 | 205 | 410
|
120,000 | 130,000 | 1,875 | 2,000 | 560 | 1,120 | 1,521 | 2,000 | 215 | 430
|
130,000 | 140,000 | 1,890 | 2,000 | 565 | 1,130 | 1,557 | 2,000 | 225 | 450
|
140,000 | 150,000 | 1,900 | 2,000 | 570 | 1,140 | 1,593 | 2,000 | 235 | 470
|
150,000 | 160,000 | 1,935 | 2,000 | 580 | 1,160 | 1,629 | 2,000 | 245 | 490
|
160,000 | 170,000 | 1,965 | 2,000 | 590 | 1,180 | 1,662 | 2,000 | 255 | 510
|
170,000 | 180,000 | 1,990 | 2,000 | 600 | 1,200 | 1,695 | 2,000 | 265 | 530
|
180,000 | 190,000 | 2,010 | 2,010 | 605 | 1,210 | 1,725 | 2,000 | 275 | 550
|
190,000 | 200,000 | 2,030 | 2,030 | 610 | 1,220 | 1,755 | 2,000 | 285 | 570
|
200,000 | 210,000 | 2,055 | 2,055 | 620 | 1,240 | 1,782 | 2,000 | 295 | 590
|
210,000 | 230,000 | 2,100 | 2,100 | 635 | 1,270 | 1,836 | 2,000 | 315 | 630
|
230,000 | 250,000 | 2,155 | 2,155 | 650 | 1,300 | 1,890 | 2,000 | 335 | 670
|
250,000 | 275,000 | 2,215 | 2,215 | 670 | 1,340 | 1,950 | 2,000 | 360 | 720
|
275,000 | 300,000 | 2,275 | 2,275 | 690 | 1,380 | 2,000 | 2,000 | 385 | 770 |
Table: American Table of Distances for Storage of Explosives (December 1910), as Revised and Approved by the Institute of Makers of Explosives—June 1991.
Notes to the Table of Distances for Storage of Explosives
(1) Terms found in the table of distances for storage of explosive materials are defined in § 555.11.
(2) When two or more storage magazines are located on the same property, each magazine must comply with the minimum distances specified from inhabited buildings, railways, and highways, and, in addition, they should be separated from each other by not less than the distances shown for “Separation of Magazines,” except that the quantity of explosives contained in cap magazines shall govern in regard to the spacing of said cap magazines from magazines containing other explosives. If any two or more magazines are separated from each other by less than the specified “Separation of Magazines” distances, then such two or more magazines, as a group, must be considered as one magazine, and the total quantity of explosives stored in such group must be treated as if stored in a single magazine located on the site of any magazine of the group, and must comply with the minimum of distances specified from other magazines, inhabited buildings, railways, and highways.
(3) All types of blasting caps in strengths through No. 8 cap should be rated at 1
1/2 lbs. (1.5 lbs.) of explosives per 1,000 caps. For strengths higher than No. 8 cap, consult the manufacturer.
(4) For quantity and distance purposes, detonating cord of 50 or 60 grains per foot should be calculated as equivalent to 9 lbs. of high explosives per 1,000 feet. Heavier or lighter core loads should be rated proportionately.
[T.D. ATF-87, 46 FR 40384, Aug. 7, 1981, as amended by T.D. ATF-400, 63 FR 45003, Aug. 24, 1998; T.D. ATF-446, 66 FR 16602, Mar. 27, 2001; T.D. ATF-446a, 66 FR 19089, Apr. 13, 2001; ATF 2017R-21, 84 FR 13800, Apr. 8, 2019]
§ 555.219 - Table of distances for storage of low explosives.
Pounds
| From inhabited building distance (feet)
| From public railroad and highway distance (feet)
| From above ground magazine (feet)
|
---|
Over
| Not over
|
---|
0 | 1,000 | 75 | 75 | 50
|
1,000 | 5,000 | 115 | 115 | 75
|
5,000 | 10,000 | 150 | 150 | 100
|
10,000 | 20,000 | 190 | 190 | 125
|
20,000 | 30,000 | 215 | 215 | 145
|
30,000 | 40,000 | 235 | 235 | 155
|
40,000 | 50,000 | 250 | 250 | 165
|
50,000 | 60,000 | 260 | 260 | 175
|
60,000 | 70,000 | 270 | 270 | 185
|
70,000 | 80,000 | 280 | 280 | 190
|
80,000 | 90,000 | 295 | 295 | 195
|
90,000 | 100,000 | 300 | 300 | 200
|
100,000 | 200,000 | 375 | 375 | 250
|
200,000 | 300,000 | 450 | 450 | 300 |
TABLE: Department of Defense Ammunition and Explosives Standards, Table 5-4.1 Extract; 4145.27 M, March 1969
[T.D. ATF-87, 46 FR 40384, Aug. 7, 1981, as amended by ATF 2017R-21, 84 FR 13800, Apr. 8, 2019]
§ 555.220 - Table of separation distances of ammonium nitrate and blasting agents from explosives or blasting agents.
Donor weight (pounds)
| Minimum separation distance of acceptor from donor when barricaded (ft.)
| Minimum thickness of artificial barricades (in.)
|
---|
Over
| Not over
| Ammonium nitrate
| Blasting agent
|
---|
| 100 | 3 | 11 | 12
|
100 | 300 | 4 | 14 | 12
|
300 | 600 | 5 | 18 | 12
|
600 | 1,000 | 6 | 22 | 12
|
1,000 | 1,600 | 7 | 25 | 12
|
1,600 | 2,000 | 8 | 29 | 12
|
2,000 | 3,000 | 9 | 32 | 15
|
3,000 | 4,000 | 10 | 36 | 15
|
4,000 | 6,000 | 11 | 40 | 15
|
6,000 | 8,000 | 12 | 43 | 20
|
8,000 | 10,000 | 13 | 47 | 20
|
10,000 | 12,000 | 14 | 50 | 20
|
12,000 | 16,000 | 15 | 54 | 25
|
16,000 | 20,000 | 16 | 58 | 25
|
20,000 | 25,000 | 18 | 65 | 25
|
25,000 | 30,000 | 19 | 68 | 30
|
30,000 | 35,000 | 20 | 72 | 30
|
35,000 | 40,000 | 21 | 76 | 30
|
40,000 | 45,000 | 22 | 79 | 35
|
45,000 | 50,000 | 23 | 83 | 35
|
50,000 | 55,000 | 24 | 86 | 35
|
55,000 | 60,000 | 25 | 90 | 35
|
60,000 | 70,000 | 26 | 94 | 40
|
70,000 | 80,000 | 28 | 101 | 40
|
80,000 | 90,000 | 30 | 108 | 40
|
90,000 | 100,000 | 32 | 115 | 40
|
100,000 | 120,000 | 34 | 122 | 50
|
120,000 | 140,000 | 37 | 133 | 50
|
140,000 | 160,000 | 40 | 144 | 50
|
160,000 | 180,000 | 44 | 158 | 50
|
180,000 | 200,000 | 48 | 173 | 50
|
200,000 | 220,000 | 52 | 187 | 60
|
220,000 | 250,000 | 56 | 202 | 60
|
250,000 | 275,000 | 60 | 216 | 60
|
275,000 | 300,000 | 64 | 230 | 60 |
Table: National Fire Protection Association (NFPA) Official Standard No. 492, 1968
Notes of Table of Separation Distances of Ammonium Nitrate and Blasting Agents From Explosives or Blasting Agents
(1) This table specifies separation distances to prevent explosion of ammonium nitrate and ammonium nitrate-based blasting agents by propagation from nearby stores of high explosives or blasting agents referred to in the table as the “donor.” Ammonium nitrate, by itself, is not considered to be a donor when applying this table. Ammonium nitrate, ammonium nitrate-fuel oil or combinations thereof are acceptors. If stores of ammonium nitrate are located within the sympathetic detonation distance of explosives or blasting agents, one-half the mass of the ammonium nitrate is to be included in the mass of the donor.
(2) When the ammonium nitrate and/or blasting agent is not barricaded, the distances shown in the table must be multiplied by six. These distances allow for the possibility of high velocity metal fragments from mixers, hoppers, truck bodies, sheet metal structures, metal containers, and the like which may enclose the “donor.” Where explosives storage is in bullet-resistant magazines or where the storage is protected by a bullet-resistant wall, distances and barricade thicknesses in excess of those prescribed in the table in § 555.218 are not required.
(3) These distances apply to all ammonium nitrate with respect to its separation from stores of high explosives and blasting agents. Ammonium nitrate explosive mixtures that are high explosives pursuant to § 555.202(a) or are defined as a blasting agent pursuant to § 555.11 are subject to the table of distances for storage of explosive materials in § 555.218 and to the table of separation distances of ammonium nitrate and blasting agents from explosives or blasting agents in this section.
(4) These distances apply to blasting agents which pass the insensitivity test prescribed in regulations of the U.S. Department of Transportation (49 CFR part 173).
(5) Earth or sand dikes, or enclosures filled with the prescribed minimum thickness of earth or sand are acceptable artificial barricades. Natural barricades, such as hills or timber of sufficient density that the surrounding exposures which require protection cannot be seen from the “donor” when the trees are bare of leaves, are also acceptable.
(6) For determining the distances to be maintained from inhabited buildings, passenger railways, and public highways, use the table in § 555.218.
[T.D. ATF-87, 46 FR 40384, Aug. 7, 1981, as amended by ATF 2017R-21, 84 FR 13800, Apr. 8, 2019; ATF 2002R-226F, 84 FR 12097, Apr. 1, 2019]
§ 555.221 - Requirements for display fireworks, pyrotechnic compositions, and explosive materials used in assembling fireworks or articles pyrotechnic.
(a) Display fireworks, pyrotechnic compositions, and explosive materials used to assemble fireworks and articles pyrotechnic shall be stored at all times as required by this Subpart unless they are in the process of manufacture, assembly, packaging, or are being transported.
(b) No more than 500 pounds (227 kg) of pyrotechnic compositions or explosive materials are permitted at one time in any fireworks mixing building, any building or area in which the pyrotechnic compositions or explosive materials are pressed or otherwise prepared for finishing or assembly, or any finishing or assembly building. All pyrotechnic compositions or explosive materials not in immediate use will be stored in covered, non-ferrous containers.
(c) The maximum quantity of flash powder permitted in any fireworks process building is 10 pounds (4.5 kg).
(d) All dry explosive powders and mixtures, partially assembled display fireworks, and finished display fireworks shall be removed from fireworks process buildings at the conclusion of a day's operations and placed in approved magazines.
[T.D. ATF-293, 55 FR 3722, Feb. 5, 1990, as amended by T.D. ATF-400, 63 FR 45004, Aug. 24, 1998]
§ 555.222 - Table of distances between fireworks process buildings and between fireworks process and fireworks nonprocess buildings.
Net weight of fireworks
1 (pounds)
| Display fireworks
2 (feet)
| Consumer fireworks
3 (feet)
|
---|
0-100 | 57 | 37
|
101-200 | 69 | 37
|
201-300 | 77 | 37
|
301-400 | 85 | 37
|
401-500 | 91 | 37
|
Above 500 | Not permitted
4 5 | Not permitted
4 5
|
[T.D. ATF-293, 55 FR 3723, Feb. 5, 1990, as amended by T.D. ATF-400, 63 FR 45004, Aug. 24, 1998]
§ 555.223 - Table of distances between fireworks process buildings and other specified areas.
Distance from Passenger Railways, Public Highways, Fireworks Plant Buildings used to Store Consumer Fireworks and Articles Pyrotechnic, Magazines and Fireworks Shipping Buildings, and Inhabited Buildings.
3 4 5
Net weight of fireworks
1 (pounds)
| Display fireworks
1 (feet)
| Consumer fireworks
2 (feet)
|
---|
0-100 | 200 | 25
|
101-200 | 200 | 50
|
201-300 | 200 | 50
|
301-400 | 200 | 50
|
401-500 | 200 | 50
|
Above 500 | Not permitted | Not permitted.
|
[T.D. ATF-293, 55 FR 3723, Feb. 5, 1990, as amended by T.D. ATF-400, 63 FR 45004, Aug. 24, 1998]
§ 555.224 - Table of distances for the storage of display fireworks (except bulk salutes).
Net weight of firework
1 (pounds)
| Distance between magazine and inhabited building, passenger railway, or public highway
3 4 (feet)
| Distance between magazines
2 3 (feet)
|
---|
0-1000 | 150 | 100
|
1001-5000 | 230 | 150
|
5001-10000 | 300 | 200
|
Above 10000 | Use table § 555.218 | |
[T.D. ATF-293, 55 FR 3723, Feb. 5, 1990, as amended by T.D. ATF-400, 63 FR 45004, Aug. 24, 1998; ATF 2017R-21, 84 FR 13800, Apr. 8, 2019]
source: T.D. ATF-87, 46 FR 40384, Aug. 7, 1981, unless otherwise noted. Redesignated by T.D. ATF-487, 68 FR 3748, Jan. 24, 2003.
cite as: 27 CFR 555.202