§ 57.8518 - Main and booster fans.
(a) All mine main and booster fans installed and used to ventilate the active workings of the mine shall be operated continuously while persons are underground in the active workings. However, this provision is not applicable during scheduled production-cycle shutdowns or planned or scheduled fan maintenance or fan adjustments where air quality is maintained in compliance with the applicable standards of subpart D of this part and all persons underground in the affected areas are advised in advance of such scheduled or planned fan shutdowns, maintenance, or adjustments.
(b) In the event of main or booster fan failure due to a malfunction, accident, power failure, or other such unplanned or unscheduled event:
(1) The air quality in the affected active workings shall be tested at least within 2-hours of the discovery of the fan failure, and at least every 4-hours thereafter by a competent person for compliance with the requirements of the applicable standards of subpart D of this part until normal ventilation is restored, or
(2) All persons, except those working on the fan, shall be withdrawn, the ventilation shall be restored to normal and the air quality in the affected active workings shall be tested by a competent person to assure that the air quality meets the requirements of the standards in subpart D of this part, before any other persons are permitted to enter the affected active workings.
§ 57.8519 - Underground main fan controls.
All underground main fans shall have controls placed at a suitable protected location remote from the fan and preferably on the surface.
§ 57.8520 - Ventilation plan.
A plan of the mine ventilation system shall be set out by the operator in written form. Revisions of the system shall be noted and updated at least annually. The ventilation plan or revisions thereto shall be submitted to the District Manager for review and comments upon his written request. The plan shall, where applicable, contain the following:
(a) The mine name.
(b) The current mine map or schematic or series of mine maps or schematics of an appropriate scale, not greater than five hundred feet to the inch, showing:
(1) Direction and quantity of principal air flows;
(2) Locations of seals used to isolate abandoned workings;
(3) Locations of areas withdrawn from the ventilation system;
(4) Locations of all main, booster and auxiliary fans not shown in paragraph (d) of this standard.
(5) Locations of air regulators and stoppings and ventilation doors not shown in paragraph (d) of this standard;
(6) Locations of overcasts, undercasts and other airway crossover devices not shown in paragraph (d) of this standard;
(7) Locations of known oil or gas wells;
(8) Locations of known underground mine openings adjacent to the mine;
(9) Locations of permanent underground shops, diesel fuel storage depots, oil fuel storage depots, hoist rooms, compressors, battery charging stations and explosive storage facilities. Permanent facilities are those intended to exist for one year or more; and
(10) Significant changes in the ventilation system projected for one year.
(c) Mine fan data for all active main and booster fans including manufacturer's name, type, size, fan speed, blade setting, approximate pressure at present operating point, and motor brake horsepower rating.
(d) Diagrams, descriptions or sketches showing how ventilation is accomplished in each typical type of working place including the approximate quantity of air provided, and typical size and type of auxiliary fans used.
(e) The number and type of internal combustion engine units used underground, including make and model of unit, type of engine, make and model of engine, brake horsepower rating of engine, and approval number.
[50 FR 4082, Jan. 29, 1985, as amended at 60 FR 33723, June 29, 1995]
§ 57.8525 - Main fan maintenance.
Main fans shall be maintained according to either the manufacturer's recommendations or a written periodic schedule adopted by the operator which shall be available at the operation on request of the Secretary or his authorized representative.
[50 FR 4082, Jan. 29, 1985, as amended at 60 FR 33723, June 29, 1995]
§ 57.8527 - Oxygen-deficiency testing.
Flame safety lamps or other suitable devices shall be used to test for acute oxygen deficiency.
§ 57.8528 - Unventilated areas.
Unventilated areas shall be sealed, or barricaded and posted against entry.
§ 57.8529 - Auxiliary fan systems.
When auxiliary fan systems are used, such systems shall minimize recirculation and be maintained to provide ventilation air that effectively sweeps the working places.
§ 57.8531 - Construction and maintenance of ventilation doors.
Ventilation doors shall be—
(a) Substantially constructed;
(b) Covered with fire-retardant material, if constructed of wood;
(c) Maintained in good condition;
(d) Self-closing, if manually operated; and
(e) Equipped with audible or visual warning devices, if mechanically operated.
§ 57.8532 - Opening and closing ventilation doors.
When ventilation control doors are opened as a part of the normal mining cycle, they shall be closed as soon as possible to re-establish normal ventilation to working places.
§ 57.8534 - Shutdown or failure of auxiliary fans.
(a) Auxiliary fans installed and used to ventilate the active workings of the mine shall be operated continuously while persons are underground in the active workings, except for scheduled production-cycle shutdowns or planned or scheduled fan maintenance or fan adjustments where air quality is maintained in compliance with the applicable standards of subpart D of this part, and all persons underground in the affected areas are advised in advance of such scheduled or planned fan shutdowns, maintenance, or adjustments.
(b) In the event of auxiliary fan failure due to malfunction, accident, power failure, or other such unplanned or unscheduled event:
(1) The air quality in the affected active workings shall be tested at least within 2 hours of the discovery of the fan failure, and at least every 4 hours thereafter by a competent person for compliance with the requirements of the applicable standards of subpart D of this part until normal ventilation is restored, or
(2) All persons, except those working on the fan, shall be withdrawn, the ventilation shall be restored to normal and the air quality in the affected active workings shall be tested by a competent person to assure that the air quality meets the requirements of the standards in subpart D of this part, before any other persons are permitted to enter the affected active workings.
§ 57.8535 - Seals.
Seals shall be provided with a means for checking the quality of air behind the seal and a means to prevent a water head from developing unless the seal is designed to impound water.
source: 50 FR 4082, Jan. 29, 1985, unless otherwise noted.