§ 139.10 - Ballast tanks.
(a) Applicability. Except for any vessel otherwise excluded in paragraph (b) of this section, the requirements in paragraphs (c) through (h) of this section apply to any vessel equipped with one or more ballast tanks.
(b) Exclusions. The requirements of this section do not apply to the following vessels:
(1) A vessel that continuously takes on and discharges ballast water in a flow-through system, if the Administrator determines that system cannot materially contribute to the spread or introduction of ANS into waters of the United States;
(2) A vessel in the National Defense Reserve Fleet scheduled for disposal, if the vessel does not have an operable ballast water management system (BWMS);
(3) A vessel that discharges ballast water consisting solely of water taken onboard from a public or commercial source that, at the time the water is taken onboard, meets the applicable requirements or permit requirements of the Safe Drinking Water Act (42 U.S.C. 300f et seq.);
(4) A vessel that carries all permanent ballast water in sealed tanks that are not subject to discharge; or
(5) A vessel that only discharges ballast water to a reception facility.
(c) Ballast Water Best Management Practices. (1) Any vessel equipped with ballast tanks must minimize the introduction and spread of aquatic nuisance species (ANS) by adhering to the following practices:
(i) Maintain a ballast water management plan that addresses both the uptake and discharge of ballast water. The plan must describe the vessel-specific BWMSs and practices necessary to comply with the requirements in this section.
(ii) Minimize the use of gravity to drain ballast tanks in port.
(iii) Use high sea suction in port or where clearance to the bottom of the waterbody is less than 5 meters to the lower edge of the sea chest, as practicable.
(iv) Avoid the discharge or uptake of ballast water in areas with coral reefs. Discharge and uptake should be conducted as far from coral reefs as practicable.
(v) Periodically clean ballast tanks to remove sediment. Discharge of sediment from ballast tank cleaning is prohibited.
(vi) Maintain, and keep fully intact, sea chest screens.
(2) Any new Laker equipped with ballast tanks must install, operate, and maintain a BWMS that has been type-approved by the USCG.
(d) Ballast Water Discharge Standard. Unless exempted in paragraph (d)(3) of this section, any ballast water discharge must meet the following numeric discharge standard:
(1) Biological parameters (expressed as instantaneous maximums).
(i) Organisms greater than or equal to 50 micrometers in minimum dimension: less than 10 living organisms per cubic meter.
(ii) Organisms less than 50 micrometers and greater than or equal to 10 micrometers: less than 10 living organisms per milliliter (mL).
(iii) Toxicogenic Vibrio cholerae (serotypes O1 and O139): less than 1 colony-forming unit (cfu) per 100 mL.
(iv) Escherichia coli: a concentration of less than 250 cfu, or Most Probable Number (MPN), per 100 mL.
(v) Intestinal enterococci: a concentration of less than 100 cfu, or MPN, per 100 mL.
(2) Biocide parameters (expressed as instantaneous maximums).
(i) Chlorine dioxide: for any discharge from a BWMS using chlorine dioxide, chlorine dioxide must not exceed 200 µg/L.
(ii) Total residual oxidizers: for any discharge from a BWMS using chlorine or ozone, total residual oxidizers must not exceed 100 µg/L.
(iii) Peracetic acid: for any discharge from a BWMS using peracetic acid, peracetic acid must not exceed 500 µg/L.
(iv) Hydrogen peroxide: for any discharge from a BWMS using peracetic acid, hydrogen peroxide must not exceed 1,000 µg/L.
(3) Exemptions: The ballast water discharge standards in paragraphs (d)(1) and (2) of this section do not apply to any vessel that:
(i) Is less than or equal to 3,000 GT (1,600 GRT if GT is not assigned), and does not operate outside of the EEZ;
(ii) Is a non-seagoing, unmanned, unpowered barge, except any barge that is part of a dedicated vessel combination such as an integrated or articulated tug and barge unit;
(iii) Takes on and discharges ballast water exclusively in the contiguous portions of a single COTP Zone;
(iv) Does not travel more than 10 NM and passes through no locks;
(v) Discharges ballast water at the same location where that ballast water originated, provided that no mixing with unmanaged ballast water or sediment from other areas has occurred;
(vi) Operates exclusively in the Great Lakes and the St. Lawrence River west of a rhumb line drawn from Cap des Rosiers to Pointe-de-l'Ouest (West Point), Anticosti Island, and west of a line along 63° W. longitude from Anticosti Island to the north shore of the St. Lawrence River;
(vii) Is enrolled in the USCG Shipboard Technology Evaluation Program (STEP); or
(viii) Discharges ballast water prior to an applicable ballast water discharge standard compliance date established in regulations promulgated by the Secretary as described in 139.1(d).
(e) Ballast Water Exchange and Saltwater Flush. Except for any vessel identified in paragraph (f) or (g) of this section, prior to an applicable ballast water discharge standard compliance date established in regulations promulgated by the Secretary as described in § 139.1(d), any vessel must meet the requirements in paragraphs (e)(1) and (2) of this section unless excluded under paragraph (e)(3) of this section.
(1) Any vessel that carries ballast water taken on in areas less than 200 NM from any shore that will subsequently operate outside the EEZ and more than 200 NM from any shore must:
(i) Conduct ballast water exchange in waters not less than 200 NM from any shore prior to discharging that ballast water; and
(ii) Commence ballast water exchange not less than 200 NM from any shore and as early in the vessel voyage as practicable.
(2) For any ballast tank that is empty or contains unpumpable residual water on a vessel bound for a port or place of destination subject to the jurisdiction of the United States, the master must, prior to arriving at that port or place of destination, either:
(i) Seal the tank so that there is no discharge or uptake and subsequent discharge of ballast water, or
(ii) Conduct a ballast water exchange or saltwater flush:
(A) Not less than 200 NM from any shore for a voyage originating outside the United States or Canadian EEZ; or
(B) Not less than 50 NM from any shore for a voyage originating within the United States or Canadian EEZ.
(3) Exceptions: Paragraphs (e)(1) and (2), do not apply under any of the following circumstances:
(i) If the unpumpable residual waters and sediments of an empty ballast tank were subject to treatment, in compliance with applicable requirements, through a BWMS approved or accepted by the Secretary;
(ii) Except as otherwise required under this part, if the unpumpable residual waters and sediments of an empty ballast tank were sourced solely within:
(A) The same port or place of destination; or
(B) Contiguous portions of a single COTP Zone;
(iii) If complying with an applicable requirement of this paragraph (e):
(A) Would compromise the safety of the vessel; or
(B) Is otherwise prohibited by any Federal, Canadian, or international law (including regulations) pertaining to vessel safety;
(iv) If design limitations of an existing vessel prevent a ballast water exchange or saltwater flush from being conducted in accordance with this paragraph (e); or
(v) If the vessel is operating exclusively within the internal waters of the United States and Canada.
(f) Vessels entering the Great Lakes. (1) Ballast Water Exchange: Except as provided in paragraph (f)(2) of this section, any vessel entering the St. Lawrence Seaway through the mouth of the St. Lawrence River must conduct a complete ballast water exchange or saltwater flush:
(i) Not less than 200 NM from any shore for a voyage originating outside the EEZ; or
(ii) Not less than 50 NM from any shore for a voyage originating within the EEZ.
(2) Exceptions: The requirements of paragraph (f)(1) of this section do not apply to any vessel if:
(i) Complying with paragraph (f)(1) of this section:
(A) Would compromise the safety of the vessel; or
(B) Is otherwise prohibited by any Federal, Canadian, or international law (including regulations) pertaining to vessel safety.
(ii) Design limitations of an existing vessel prevent a ballast water exchange from being conducted in accordance with an applicable requirement of paragraph (f)(1) of this section.
(iii) The vessel has no residual ballast water or sediments onboard.
(iv) The vessel retains all ballast water while in waters subject to the requirement.
(v) The empty ballast tanks on the vessel are sealed in a manner that ensures that no discharge or uptake occurs, and any subsequent discharge of ballast water is subject to the requirement.
(g) Pacific Region. (1) Ballast Water Exchange:
(i) Except as provided in paragraphs (g)(1)(ii) and (g)(3) of this section, any vessel that operates either between two ports or places of destination within the Pacific Region; or a port or place of destination within the Pacific Region and a port or place of destination on the Pacific Coast of Canada or Mexico north of parallel 20 degrees north latitude, inclusive of the Gulf of California, must conduct a complete ballast water exchange in waters more than 50 NM from shore.
(ii) Exemptions: The requirements of paragraph (g)(1)(i) of this section do not apply to any vessel:
(A) Using, in compliance with applicable requirements, a type-approved BWMS approved or accepted by the Secretary.
(B) Voyaging:
(1) Between or to a port or place of destination in the State of Washington, if the ballast water to be discharged from the commercial vessel originated solely from waters located between the parallel 46 degrees north latitude, including the internal waters of the Columbia River, and the internal waters of Canada south of parallel 50 degrees north latitude, including the waters of the Strait of Georgia and the Strait of Juan de Fuca;
(2) Between ports or places of destination in the State of Oregon, if the ballast water to be discharged from the commercial vessel originated solely from waters located between the parallel 40 degrees north latitude and the parallel 50 degrees north latitude;
(3) Between ports or places of destination in the State of California within the San Francisco Bay area east of the Golden Gate Bridge, including the Port of Stockton and the Port of Sacramento, if the ballast water to be discharged from the commercial vessel originated solely from ports or places within that area;
(4) Between the Port of Los Angeles, the Port of Long Beach, and the El Segundo offshore marine oil terminal, if the ballast water to be discharged from the commercial vessel originated solely from the Port of Los Angeles, the Port of Long Beach, or the El Segundo offshore marine oil terminal;
(5) Between a port or place of destination in the State of Alaska within a single COTP Zone;
(6) Between ports or places of destination in different counties of the State of Hawaii, if the vessel conducts a complete ballast water exchange in waters that are more than 10 NM from shore and at least 200 meters deep; or
(7) Between ports or places of destination within the same county of the State of Hawaii, if the vessel does not transit outside State marine waters during the voyage.
(2) Low-Salinity Ballast Water:
(i) Except as provided in paragraphs (g)(2)(ii) and (g)(3) of this section, a complete ballast water exchange must be conducted for any commercial vessel that transports ballast water sourced from waters with a measured salinity of less than 18 parts per thousand and voyages to a Pacific Region port or place of destination with a measured salinity of less than 18 parts per thousand:
(A) Not less than 50 NM from shore, if the ballast water was sourced from a Pacific Region port or place of destination.
(B) More than 200 NM from shore, if the ballast water was not sourced from a Pacific Region port or place of destination.
(ii) Exception: The requirements of paragraph (g)(2)(i) of this section do not apply to any vessel voyaging to a port or place of destination in the Pacific Region that is using, in compliance with applicable requirements, a type-approved BWMS accepted by the Secretary, or a type-approved BWMS approved by the Secretary to achieve the following numeric discharge standard for biological parameters (expressed as instantaneous maximums):
(A) Organisms greater than or equal to 50 micrometers in minimum dimension: less than 1 living organism per 10 cubic meters.
(B) Organisms less than 50 micrometers and greater than or equal to 10 micrometers: Less than 1 living organisms per 10 milliliters (mL).
(C) Toxicogenic Vibrio cholerae (serotypes O1 and O139): less than 1 colony-forming unit (cfu) per 100 mL or less than 1 cfu per gram of wet weight of zoological samples.
(D) Escherichia coli: less than 126 cfu, or MPN, per 100 mL.
(E) Intestinal enterococci: less than 33 cfu, or MPN, per 100 mL.
(3) General Exceptions: The requirements of paragraphs (g)(1) and (2) of this section do not apply to a commercial vessel if:
(i) Complying with the requirement would compromise the safety of the commercial vessel.
(ii) If design limitations of an existing vessel, prevent a ballast water exchange from being conducted in accordance with paragraphs (g)(1) and (2) of this section, as applicable.
(iii) The commercial vessel:
(A) Has no residual ballast water or sediments onboard; or
(B) Retains all ballast water while in waters subject to those requirements.
(iv) Empty ballast tanks on the commercial vessel are sealed in a manner that ensures that:
(A) No discharge or uptake occurs; and
(B) Any subsequent discharge of ballast water is subject to those requirements.
(h) Federally-protected waters. Additional standards applicable to discharges from ballast tanks when a vessel is operating in federally-protected waters are contained in § 139.40(b).
§ 139.11 - Bilges.
(a) The requirements in paragraphs (b) through (d) of this section applies to bilgewater, which is the discharge of wastewater from the bilge consisting of water and residue that accumulates in a lower compartment of the vessel's hull below the waterline. This includes, but is not limited to, any water and residue from a cargo area that comes into contact with oily materials or a below-deck parking area or other storage area for motor vehicles or other motorized equipment.
(b) The discharge of bilgewater from any vessel must not contain any flocculants or other additives except when used with an oily water separator or to maintain or clean equipment. The use of any additives to remove the appearance of a visible sheen is prohibited.
(c) For any vessel of 400 GT and above, the discharge of bilgewater must:
(1) Occur when the vessel is underway;
(2) Not have an oil content that exceeds 15 ppm; and
(3) If technologically feasible, occur at least 1 NM from shore.
(d) Additional standards applicable to discharges from bilges when a vessel is operating in federally-protected waters are contained in § 139.40(c).
§ 139.12 - Boilers.
(a) The requirements in paragraphs (b) and (c) of this section apply to discharges resulting from boiler blowdown.
(b) The discharge from boiler blowdown must be minimized in port.
(c) Additional standards applicable to discharges from boilers when a vessel is operating in federally-protected waters are contained in § 139.40(d).
§ 139.13 - Cathodic protection.
(a) The requirements in paragraph (b) of this section apply to discharges resulting from a vessel's cathodic corrosion control protection device, including but not limited to sacrificial anodes and impressed current cathodic protection (ICCP) systems.
(b) Spaces between any flush-fit anode and backing must be filled to remove potential hotspots for biofouling organisms.
(c) The vessel operator must consider using, but is not required to use, less toxic metals when selecting sacrificial anodes.
§ 139.14 - Chain lockers.
(a) The requirements in paragraphs (b) through (e) of this section apply to accumulated biological organisms, sediment, precipitation, and seawater that is emptied from the compartment used to store the anchor chain on a vessel and are intended to prevent the discharge of accumulated biological organisms, sediment, precipitation, and seawater when deploying the anchor in a new port or place of destination.
(b) Anchors and anchor chains must be rinsed of biofouling organisms and sediment when the anchor is retrieved.
(c) The discharge of biological organisms, sediment, precipitation, and seawater from any chain locker is prohibited in port.
(d) Anchors and anchor chains used beyond waters of the contiguous zone must be rinsed of biofouling organisms and sediment prior to entering the waters of the contiguous zone. This requirement may be satisfied by rinsing when the anchor is retrieved at the commencement of the voyage or when the anchor was last retrieved on a previous voyage, so long as the rinsing occurs after the last use of the anchor beyond waters of the contiguous zone.
(e) Additional standards applicable to a discharge from chain lockers when a vessel is operating in federally-protected waters are contained in § 139.40(e).
§ 139.15 - Decks.
(a) The requirements in paragraphs (b) through (i) of this section apply to the discharge of washdown and runoff from decks, well decks, and bulkhead areas, including but not limited to precipitation, condensation, seawater spray and wash over, and flooding, as well as waters pumped from below deck on a barge.
(b) Coamings or drip pans must be used for machinery that is expected to leak or otherwise release oil on the deck; accumulated oil must be collected.
(c) Where required by an applicable international treaty or convention or the Secretary, the vessel must be fitted with and use physical barriers (e.g., spill rails, scuppers and scupper plugs) during any washdown.
(d) Control measures must be used to minimize the introduction of on-deck debris, garbage, residue, spills, floating solids, visible foam, halogenated phenolic compounds, dispersants, and surfactants into deck washdown and runoff.
(e) Vessel decks must be kept in broom clean condition whenever the vessel is underway and prior to any deck washdown.
(f) Discharges from deck washdowns must be minimized in port.
(g) Any soap, cleaner, or detergent used for deck washdown must be minimally-toxic, phosphate-free, and biodegradable.
(h) Barges that discharge water pumped from below deck must minimize the contact of below deck condensation with oily or toxic materials and any materials containing hydrocarbons.
(i) Additional standards applicable to discharges from decks when a vessel is operating in federally-protected waters are contained in § 139.40(f).
§ 139.16 - Desalination and purification systems.
(a) The requirements in paragraph (b) of this section apply to discharges from onboard desalination and purification systems used to generate freshwater from seawater or otherwise purify water.
(b) The discharge resulting from the cleaning of desalination and purification systems with toxic or hazardous materials is prohibited.
§ 139.17 - Elevator pits.
(a) The requirements in paragraph (b) of this section apply to the liquid that accumulates in, and is discharged from, the sumps of elevator wells.
(b) The discharge of untreated accumulated water and sediment from any elevator pit is prohibited.
§ 139.18 - Exhaust gas emission control systems.
(a) Applicability. The requirements in paragraphs (b) through (d) of this section apply to discharges from the operation and cleaning of any exhaust gas cleaning system (EGCS) and exhaust gas recirculation (EGR) system.
(b) Discharge requirements. Unless excluded in paragraph (c) of this section, any discharge identified in paragraph (a) of this section must meet the following discharge requirements.
(1) pH. (i) The discharge must meet one of the following requirements:
(A) The discharge must have a pH of no less than 6.5 as measured at the vessel's overboard discharge point with the exception that during maneuvering and transit, the maximum difference of two pH units is allowed between inlet water and overboard discharge values; or
(B) The pH discharge limit is the value that will achieve a minimum pH of 6.5 at 4 meters from the overboard discharge point with the vessel stationary. This overboard pH discharge limit is to be determined at the overboard discharge monitoring point and is to be recorded as the vessel's discharge limit. The overboard pH limit can be determined either by means of direct measurement, or by using a calculation-based methodology (computational fluid dynamics or other equally scientifically established empirical formulas).
(ii) The pH numeric discharge standard may be exceeded for up to 15 minutes in any 12-hour period.
(2) PAHs (Polycyclic Aromatic Hydrocarbons). (i) The maximum continuous PAH concentration in the discharge must be no greater than 50 µg/L PAHphe (phenanthrene equivalents) above the inlet water PAH concentration. This standard applies downstream of any washwater treatment equipment including any reactant dosing unit but upstream of any seawater addition for control of pH prior to discharge.
(ii) The 50 µg/L numeric discharge standard is normalized for a discharge flow rate, before any seawater neutralization for pH control, of 45 tons (t)/megawatt-hour (MWh) where the mega-watt (MW) refers to the Maximum Continuous Rating (MCR) or 80% of the power rating of the fuel oil combustion units whose EGCS discharge water PAH is being monitored at that point. In cases where sensors are installed in a separate measurement cell, the PAH limit applies to the flow in the main discharge pipe from which the water is bypassed. This numeric discharge standard is adjusted upward or downward for different discharge flow rates, pursuant to table 1 to paragraph (b)(2)(ii) of this section.
Table 1 to Paragraph (b)(2)(ii)
Discharge water flowrate before any seawater addition for pH control
(t/MWh)
| Numeric discharge standard
(µg/L PAHphe equivalents)
| Measurement technology
|
---|
0-1 | 2,250 | Ultraviolet light
|
2.5 | 900 | - ″ -
|
5 | 450 | Fluorescence
a
|
11.25 | 200 | - ″ -
|
22.5 | 100 | - ″ -
|
45 | 50 | - ″ -
|
90 | 25 | - ″ -
|
(iii) The continuous PAHphe numeric discharge standard may be exceeded by 100% for up to 15 minutes in any 12-hour period.
(3) Turbidity/suspended particulate matter. (i) The washwater treatment system must be designed to minimize suspended particulate matter, including but not limited to heavy metals and ash.
(ii) The maximum continuous turbidity in the discharge must be no greater than 25 FNU (formazin nephlometric units) or 25 NTU (nephlometric turbidity units) or equivalent units above the inlet water turbidity. However, to account for periods of high inlet turbidity, readings must be a rolling average over a 15-minute period to a maximum of 25 FNU or NTU. This standard applies downstream of any washwater treatment equipment including any reactant dosing unit but upstream of any seawater addition for control of pH prior to discharge.
(iii) For an aggregated 15-minute period in any rolling 12-hour period, the continuous turbidity discharge limit may be exceeded by 20%.
(4) Nitrates plus nitrites:
(i) The washwater treatment system must prevent the discharge of nitrates plus nitrites beyond that associated with a 12% removal of NOX from the exhaust, or beyond 60 mg/L normalized for a discharge rate of 45 tons/MWh, whichever is greater, where the MW refers to the MCR or 80% of the power rating of all those fuel oil combustion units whose EGCS discharge water nitrates plus nitrites are being monitored at that point. This standard applies downstream of any washwater treatment equipment including any reactant dosing unit but upstream of any seawater addition for control of pH prior to discharge. The 60-mg/L limit is adjusted upward for lower washwater flow rates per MWh, and vice-versa, and the applicable permit limits are contained in table 2 to paragraph (b)(4)(i) of this section.
Table 2 to Paragraph (b)(4)(i)
Discharge water flowrate before any seawater addition for pH control
(t/MWh)
| Numeric discharge standard
(mg/L nitrate + nitrite)
|
---|
0-1 | 2,700
|
2.5 | 1,080
|
5 | 540
|
11.25 | 240
|
22.5 | 120
|
45 | 60 |
(5) Discharge water from temporary storage:
(i) pH. See § 139.18(b)(1).
(ii) PAH. Maximum of 50 µg/L PAHphe before any addition of seawater (or similar) for control of pH.
(iii) Turbidity. Not greater than 25 FNU or 25 NTU or equivalent units, before any addition of seawater (or similar) for pH control.
(6) Treatment Residuals: Discharges of sludge or residues generated from treatment of EGCS or EGR washwater or bleed-off water are prohibited.
(c) Exclusion. For a vessel operating on fuel that meets the sulfur content limits specified in Regulation 14 of MARPOL Annex VI, discharge of EGR bleed-off water is excluded from paragraph (b) of this section if the vessel:
(1) Does not retain the EGR bleed-off onboard in a holding tank prior to discharge, and
(2) Is underway, and
(3) Not in port.
(d) Prohibition. For a vessel not operating on fuel that meets the sulfur content limits specified in Regulation 14 of MARPOL Annex VI, discharge of EGR bleed-off water which is retained in a holding tank is prohibited unless the vessel:
(1) Is underway;
(2) Not in port; and
(3) In compliance with the discharge standard in paragraph (b) of this section.
§ 139.19 - Fire protection equipment.
(a) The requirements in paragraphs (b) through (e) of this section apply to the discharge from fire protection equipment, including discharges for secondary purposes (e.g., anchor and anchor chain rinsing and deck washdown). As specified in § 139.1(b)(3), these requirements do not apply to discharges from fire protection equipment when used for emergencies or when compliance with such requirements would compromise the safety of the vessel or life at sea.
(b) The discharge of fluorinated firefighting foam is prohibited unless required for certification or inspection under 46 CFR 31.10 through 31.18(c), 46 CFR 107.235(b)(4), or by the marine inspector to ensure vessel safety and seaworthiness.
(c) The discharge from fire protection equipment to ensure operability (e.g., during testing, training, maintenance, inspection, or certification) is prohibited in port unless:
(1) The intake is drawn from surrounding waters or a potable water supply and contains no additives (e.g., firefighting foam); or
(2) Required in port by the Secretary for certification or inspection under 46 CFR 31.10 through 31.18(c), 46 CFR 107.235(b)(4), or by the marine inspector to ensure vessel safety.
(d) The discharge from fire protection equipment for secondary uses is prohibited in port unless:
(1) The intake is drawn from surrounding waters or a potable water supply and contains no additives (e.g., firefighting foam); and
(2) The discharge meets applicable requirements under this part for the secondary use.
(e) Additional requirements applicable to discharges from fire protection equipment when a vessel is operating in federally-protected waters are contained in § 139.40(g).
§ 139.20 - Gas turbines.
(a) The requirements in paragraph (b) of this section apply to discharges from the washing of gas turbine components.
(b) The discharge of untreated gas turbine washwater is prohibited unless infeasible.
§ 139.21 - Graywater systems.
(a) The requirements in paragraphs (b) through (g) of this section apply to discharges of graywater except for graywater from any commercial vessel on the Great Lakes that is subject to the requirements in 40 CFR part 140 and 33 CFR part 159.
(b) The introduction of kitchen waste, food, oils, and oily residues to the graywater system must be minimized.
(c) Any soaps, cleaners, detergents, and other substances used by vessel operators or provided by vessel operators to persons onboard and discharged in graywater must be minimally-toxic, phosphate-free, and biodegradable.
(d) The discharge of graywater is prohibited from any vessel:
(1) Within 3 NM from shore that voyages at least 3 NM from shore and has remaining available graywater storage capacity, unless the discharge meets the standards in paragraph (f) of this section; and
(2) Within 1 NM from shore that voyages at least 1 NM from shore but not beyond 3 NM from shore and has remaining available graywater storage capacity, unless the discharge meets the standards in paragraph (f) of this section.
(e) The discharge of graywater from the following vessels must meet the numeric discharge standard established in paragraph (f) of this section:
(1) Any new vessel of 400 GT (400 GRT if GT is not assigned) and above that is certificated to carry 15 or more persons and provides overnight accommodations to those persons;
(2) Any passenger vessel, excluding any ferry, with overnight accommodations for 500 or more persons;
(3) Any passenger vessel, excluding any ferry, with overnight accommodations for 100-499 persons unless the vessel was constructed before December 19, 2008, and does not voyage beyond 1 NM from shore; and
(4) Any new ferry authorized by the Secretary to carry 250 or more persons.
(f) A vessel identified in paragraph (d) or (e) of this section that is discharging graywater must meet the following numeric discharge standard:
(1) Fecal coliform. (i) The 30-day geometric mean must not exceed 20 cfu, or MPN, per 100 mL.
(ii) Greater than 90% of samples must not exceed 40 cfu, or MPN, per 100 mL during any 30-day period.
(2) BOD5. (i) The 30-day average must not exceed 30 mg/L.
(ii) The 7-day average must not exceed 45 mg/L.
(3) Suspended solids. (i) The 30-day average must not exceed 30 mg/L.
(ii) The 7-day average must not exceed 45 mg/L.
(4) pH. (i) Must be maintained between 6.0 and 9.0.
(ii) [Reserved]
(5) Total residual oxidizers. (i) For any discharge from a graywater system using chlorine, total residual oxidizers must not exceed 10.0 µg/L.
(ii) [Reserved]
(g) Unless from a vessel subject to paragraph (e) of this section, the discharge of graywater from any vessel operating on the Great Lakes that is not a commercial vessel must not exceed 200 fecal coliform forming units per 100 milliliters and contain no more than 150 milligrams per liter of suspended solids.
(h) Additional standards applicable to discharges from graywater systems when a vessel is operating in federally-protected waters are contained in § 139.40(h).
§ 139.22 - Hulls and associated niche areas.
(a) Applicability. The requirements in paragraphs (b) through (d) of this section apply to the discharge of anti-fouling coatings, biofouling organisms, and other materials from vessel hull and niche areas.
(b) Transport and passive discharge. The transport of attached living organisms and passive discharge of biofouling must be minimized when traveling into U.S. waters from outside the EEZ or between COTP Zones. Management measures to minimize the transport of attached living organisms and the passive discharge of biofouling are described in paragraphs (c) and (d) of this section.
(c) Anti-fouling coatings. (1) Anti-fouling coatings applied to the vessel must be specific to the operational profile of the vessel and the equipment to which it is applied, including, for biocidal coatings, having appropriate biocide release rates and components that are biodegradable once separated from the vessel surface.
(2) Anti-fouling coatings must be applied, maintained, and reapplied consistent with manufacturer specifications, including but not limited to the thickness, the method of application, and the lifespan of the coating.
(3) Anti-fouling coatings must not contain tributyltin (TBT) or any other organotin compound used as a biocide.
(i) Any vessel hull previously covered with an anti-fouling coating containing TBT (whether or not used as a biocide) or any other organotin compound (if used as a biocide) must:
(A) Maintain an effective overcoat that forms a barrier so that no TBT or other organotin leaches from the underlying anti-fouling coating; or
(B) Remove any TBT or other organotin compound from the vessel hull.
(4) When an organotin compound other than TBT is used as a catalyst in the anti-fouling coating (e.g., dibutyltin), the anti-fouling coating must:
(i) Contain less than 2,500 mg total tin per kilogram of dry paint; and
(ii) Not be designed to slough or otherwise peel from the vessel hull, noting that incidental amounts of anti-fouling coating discharged by abrasion during cleaning or after contact with other hard surfaces (e.g., moorings) are acceptable.
(5) Anti-fouling coatings must not contain cybutryne.
(i) Any vessel that has previously applied an anti-fouling coating that contains cybutryne in the external coating layer of their hulls or external parts or surfaces must:
(A) Apply and maintain an effective overcoat that forms a barrier so that no cybutryne leaches from the underlying anti-fouling coating, noting that incidental amounts of anti-fouling coating discharged by abrasion during cleaning or after contact with other hard surfaces (e.g., moorings) are acceptable; or
(B) Remove any cybutryne coating.
(6) As appropriate based on vessel class and operations, alternatives to copper-based anti-fouling coatings (e.g., non-biocidal anti-fouling coatings) or coating with lower biocidal release rates must be considered for vessels spending 30 or more days per year in a copper-impaired waterbody or using these waters as their home port.
(d) Cleaning. (1) Cleanings should take place in drydock when practicable.
(2) Hulls and niche areas must be managed to minimize biofouling such as through preventative cleaning of microfouling.
(3) Hull and niche area cleanings must minimize damage to the anti-fouling coating, minimize release of biocides, and follow applicable cleaning requirements found on the coating manufacturers' instructions and any applicable FIFRA label.
(4) Any discharge from in-water cleaning without capture of macrofouling is prohibited.
(5) Any discharge from in-water cleaning without capture of any copper-based hull coating in a copper-impaired water body within the first 365 days after application of that coating is prohibited.
(6) In-water cleaning must not be conducted on any section of an anti-fouling coating that shows excessive cleaning actions (e.g., brush marks) or blistering due to the internal failure of the paint system.
(7) Any soap, cleaner, or detergent used on vessel surfaces, including but not limited to a scum line of the hull, must be minimally toxic, phosphate-free, and biodegradable.
(8) Additional standards applicable to discharges from hulls and associated niche areas when a vessel is operating in federally-protected waters are contained in § 139.40(i).
§ 139.23 - Inert gas systems.
There are no additional discharge-specific requirements that apply to the discharge of washwater from an inert gas system and deck seal water when used as an integral part of that system.
§ 139.24 - Motor gasoline and compensating systems.
(a) The requirements in paragraph (b) of this section apply to the discharge of motor gasoline and compensating ambient water added to keep gasoline tanks full to prevent potentially explosive gasoline vapors from forming.
(b) Additional standards applicable to discharges from motor gasoline and compensating systems when a vessel is operating in federally-protected waters are contained in § 139.40(j).
§ 139.25 - Non-oily machinery.
(a) The requirements in paragraph (b) of this section apply to discharges from machinery that contains no oil, including but not limited to discharges from the operation of desalination systems, water chillers, valve packings, water piping, low- and high-pressure air compressors, propulsion engine jacket coolers, fire pumps, and seawater and potable water pumps.
(b) The discharge of untreated non-oily machinery wastewater and packing gland or stuffing box effluent containing toxic or bioaccumulative additives, or the discharge of oil in such quantities as may be harmful, is prohibited.
§ 139.26 - Pools and spas.
(a) The requirements in paragraphs (b) and (c) of this section apply to discharges from pools and spas.
(b) Except for unintentional or inadvertent releases from overflows across the decks and into overboard drains caused by, but not limited to, weather, vessel traffic, marine wildlife avoidance or navigational maneuvering, discharge of pool and spa water must:
(1) Occur only while the vessel is underway, unless determined to be infeasible; and
(2) Meet the following numeric discharge standard:
(i) For chlorine disinfection: total residual chlorine less than 100 µg/L; and
(ii) For bromine disinfection: total residual oxidant less than 25 µg/L.
(c) Additional standards applicable to discharges from pools and spas when a vessel is operating in federally-protected waters are contained in § 139.40(k).
§ 139.27 - Refrigeration and air conditioning.
(a) The requirements in paragraph (b) of this section apply to discharges of condensation from refrigeration, air conditioning, and similar chilling equipment.
(b) The direct overboard discharge of any condensate that contacts toxic or hazardous materials is prohibited.
§ 139.28 - Seawater piping.
(a) The requirements in paragraphs (b) through (d) of this section apply to discharges from seawater piping systems, including while a vessel is in port or in layup.
(b) Seawater piping systems must be inspected, maintained, and cleaned as necessary to minimize the accumulation and discharge of biofouling organisms.
(c) Seawater piping systems that accumulate macrofouling must be fitted with a Marine Growth Prevention System (MGPS).
(1) An MGPS must be selected to address:
(i) The level, frequency, and type of expected biofouling; and
(ii) The design, location, and area in which the system will be used.
(2) An MGPS must include one, or some combination of the following:
(i) Chemical injection;
(ii) Electrolysis, ultrasound, ultraviolet radiation, or electrochlorination;
(iii) Application of an antifouling coating;
(iv) Use of cupro-nickel piping; or
(v) Use of glass-reinforced/filament-wound epoxy-based composite piping.
(3) Upon identification of macrofouling in a seawater piping system, reactive measures to manage the macrofouling must be used. Discharges resulting from reactive measures to remove macrofouling are prohibited in port.
(d) Additional standards applicable to discharges from seawater piping systems when a vessel is operating in federally-protected waters are contained in § 139.40(l).
§ 139.29 - Sonar domes.
(a) The requirements in paragraphs (b) and (c) of this section apply to discharges from sonar domes.
(b) The discharge of water from inside the sonar dome is prohibited during maintenance or repair.
(c) Any discharge from the use of bioaccumulative biocides on the exterior of the sonar dome is prohibited when non-bioaccumulative alternatives are available.
source: 89 FR 82131, Oct. 9, 2024, unless otherwise noted.