Regulations last checked for updates: Nov 23, 2024

Title 40 - Protection of Environment last revised: Nov 21, 2024
§ 417.190 - Applicability; description of the manufacture of detergent bars and cakes subcategory.

The provisions of this subpart are applicable to discharges resulting from operations associated with the manufacture of detergent bars and cakes, including, but not limited to, drying, milling, plodding, stamping and packaging.

§ 417.191 - Specialized definitions.

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term anhydrous product shall mean the theoretical product that would result if all water were removed from the actual product.

(c) The term surfactant shall mean those methylene blue active substances amenable to measurement by the method described in “Methods for Chemical Analysis of Water and Wastes,” 1971, Environmental Protection Agency, Analytical Quality Control Laboratory, page 131.

§ 417.192 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of anhydrous product)
BOD52.100.70
COD9.903.30
TSS0.60.20
Surfactants1.50.50
Oil and grease0.06.50
pH( 1)( 1)
English units (pounds per 1,000 lb of anhydrous product)
BOD52.100.70
COD9.903.30
TSS0.60.20
Surfactants1.50.50
Oil and grease0.06.50
pH( 1)( 1)

1 Within the range 6.0 to 9.0.

[39 FR 13372, Apr. 12, 1974, as amended at 60 FR 33956, June 29, 1995]
§ 417.193 - Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.

The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable:

Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of anhydrous product)
BOD50.600.30
COD2.701.35
TSS0.20.10
Surfactants0.40.10
Oil and grease0.04.02
pH( 1)( 1)
English units (pounds per 1,000 lb of anhydrous product)
BOD50.600.30
COD2.701.35
TSS0.20.10
Surfactants0.40.10
Oil and grease0.04.02
pH( 1)( 1)

1 Within the range 6.0 to 9.0.

§ 417.194 - Pretreatment standards for existing sources.

Any existing source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a point source subject to the provisions of this subpart.

Pollutant or pollutant property Pretreatment standard
pHNo limitation.
BOD5 Do.
TSS Do.
Oil and grease Do.
COD Do.
Surfactants Do.
[40 FR 6443, Feb. 11, 1975, as amended at 60 FR 33956, June 29, 1995]
§ 417.195 - Standards of performance for new sources.

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kilograms per 1,000 kg of anhydrous product)
BOD50.600.30
COD2.701.35
TSS0.20.10
Surfactants0.40.20
Oil and grease0.04.02
pH( 1)( 1)
English units (pounds per 1,000 lb of anhydrous product)
BOD50.600.30
COD2.701.35
TSS0.20.10
Surfactants0.40.20
Oil and grease0.04.02
pH( 1)( 1)

1 Within the range 6.0 to 9.0.

§ 417.196 - Pretreatment standards for new sources.

Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403.

[60 FR 33956, June 29, 1995]
authority: Secs. 301, 304 (b) and (c), 306 (b) and (c), and 307(c) of the Federal Water Pollution Control Act as amended, (the Act); 33 U.S.C. 1251,1311,1314,1316,86. 816
source: 39 FR 13372, Apr. 12, 1974, unless otherwise noted.
cite as: 40 CFR 417.192