Each applicant for approval of plans must submit three copies of each of the following described plans, specifications, and structural calculations concerning the construction, arrangement, required equipment, and safety features of the unit:
General
(a) Specifications.
(b) General arrangement plan of decks, holds, inner bottoms, etc. including inboard and outboard profile.
Hull Structure
1
1 The asterisk (*) indicates items that are approved by the American Bureau of Shipping for vessels classed by it. Items approved by the American Bureau of Shipping are generally accepted as satisfactory unless the law or Coast Guard regulations contain requirements that are not covered by the American Bureau of Shipping.
(c) *Inner bottom plating and framing.
(d) *Midship section.
(e) *Shell plating and framing.
(f) *Stern, stern frame, and rudder.
(g) *Structural deck plans for strength decks.
(h) *Pillars and girders.
(i) *Watertight and oiltight bulkheads.
(j) *Foundations for main machinery and boilers.
(k) *Arrangement of ports, doors, and airports in shell plating.
(l) *Hatch coamings and covers in weather and watertight decks.
(m) *Details of hinged subdivision watertight doors and operating gear.
(n) *Scuppers and drains penetrating shell plating.
(o) Arrangement of cranes.
(p) For self-elevating units, column stabilized units, and units with special hull configuration, structural calculations and plans showing special structural features.
Stability
(q) The plans and information required by Subchapter S of this chapter.
(r) For vessels of 100 meters (328 feet) or more in length contracted for on or after September 7, 1990, a plan must be included which shows how visibility from the navigation bridge will meet the standards contained in § 108.801 of this subchapter.
(s)-(u) [Reserved]
Fire Control
(v) General arrangement plans showing, for each deck, the control stations, fire sections enclosed by fire resisting bulkheads, alarm and extinguishing systems, fire extinguishers, means of access to compartments and other decks, and the ventilation system, including location of ventilation shutdowns, positions of dampers, and the numbers identifying each system.
(w) Ventilation diagram, including dampers and other fire control features.
(x) Details of fire alarm systems.
(y) Details of fixed fire extinguishing systems.
Marine Engineering
(z) Plans required for marine engineering equipment and systems by Subchapter F of this chapter.
Electrical Engineering
(aa) Plans required for electrical engineering equipment and systems by Subchapter J of this chapter.
Life Saving Equipment
(bb) The location and arrangement of each lifesaving system including each embarkation deck, showing each overboard discharge and clearances from projections and obstructions in the way of launching lifeboats, rescue boats, and liferafts throughout the range of list and trim angles required under part 108, subpart E of this chapter.
(cc) The design weight of each lifeboat, rescue boat, and davit-launched liferaft when fully equipped and loaded.
(dd) Working loads of davits and winches.
(ee) Types and sizes of falls.
(ff) Manufacturer's name and identification of each item of equipment.
Personnel Accommodations
(gg) Arrangement plans showing each accommodation space, ventilation, and means of escape.
Construction Portfolio
2
2 This portfolio may be included in the operating manual required in § 109.121.
(hh) A construction portfolio must be prepared for each unit and must be approved by the Coast Guard. The portfolio must document the location and extent of application of different grades and strengths of materials and include a description of the materials and welding procedures employed and any other relevant construction information. The portfolio must contain the following:
(1) Structural plans showing areas incorporating different grades and strengths of materials. A simplified plan may be included in the portfolio if it adequately defines the different areas of application.
(2) A list of different grades or strengths of material that conform to American Bureau of Shipping (ABS) or American Society of Testing and Materials (ASTM) specifications. For materials that do not conform to ABS or ASTM specifications, complete specifications, including chemical and physical properties, special testing and any heat treatment.
(3) Each approved weld procedure for the fabrication of each structure using different grades or strengths of material and each approved weld test procedure.
(4) Information, restrictions or prohibitions regarding repairs or modifications.
Operating Manual
(ii) The operating manual required in § 109.121. If an approved manual is changed, only the pages affected by the change need be submitted if the manual is bound in such a way as to allow old pages to be removed easily and new ones inserted and if the manual has a record of page changes.
[CGD 73-251, 43 FR 56802, Dec. 4, 1978, as amended by CGD 79-023, 48 FR 51008, Nov. 4, 1983; CGD 83-071, 52 FR 6978, Mar. 6, 1987; CGD 85-099, 55 FR 32248, Aug. 8, 1990; CGD 88-032, 56 FR 35826, July 29, 1991; CGD 84-069, 61 FR 25290, May 20, 1996; 63 FR 52814, Oct. 1, 1998]
(a) Three copies of each of the following must be submitted:
(1) Stress and arrangement diagrams, bill of materials, and supporting calculations for all structural components listed in API Spec. 2C, Second Edition, February 1972 (with supplement 2).
(2) Drawings of foundations and substructures with supporting calculations for support and stability of each crane under its rated load.
(3) Plans showing the installation of the safety features required in § 108.601.
(4) Drawings of the means provided to stop motion and set brakes during a power failure.
Note to § 107.309(a)(4):
These plans must be submitted to the Coast Guard, if the crane is not certified. If the crane is to be certified, four copies must be sent to the American Bureau of Shipping or the International Cargo Gear Bureau, Inc.
(b) In addition to the plans and information required in paragraph (a), the following plans and information must be submitted to the Coast Guard only:
(1) One line diagrams of the electrical power circuits of the electric power crane overload protection required in Subpart 111.50 of this chapter.
(2) Diagrams of the hydraulic or pneumatic power and control systems, as required by Subpart 58.30-40 or 58.30-50 of this chapter, as applicable.
[CGD 73-251, 43 FR 56802, Dec. 4, 1978, as amended by USCG-2008-0906, 73 FR 56510, Sept. 29, 2008]
The copies of each plan, specification, and calculation required under § 107.305 and § 107.309 must be submitted to one of the following as applicable:
(a) The Officer in Charge, Marine Inspection, in the zone in which the unit is to be built or altered.
(b) By visitors to the Commanding Officer, Marine Safety Center, U.S. Coast Guard, 2703 Martin Luther King Jr. Avenue SE., Washington, DC 20593, or by mail to: Commanding Officer (MSC), Attn: Marine Safety Center, U.S. Coast Guard Stop 7430, 2703 Martin Luther King Jr. Avenue SE., Washington, DC 20593-7430, in a written or electronic format. Information for submitting the VSP electronically can be found at http://www.uscg.mil/HQ/MSC.
(c) The American Bureau of Shipping, (ABS) ABS Plaza, 16855 Northchase Drive, Houston, TX 77060.
Note:
For classed vessels, the American Bureau of Shipping will, upon request by the submitter, arrange to forward the plans indicated with an asterisk in § 107.305 to the Coast Guard indicating ABS's action thereon.
(d) International Cargo Gear Bureau, Inc., 481 Eighth Avenue, New York, NY 10001, on the internet at http://www.icgb.com.
[CGD 73-251, 43 FR 56802, Dec. 4, 1978, as amended by CGD 85-048b, 51 FR 15498, Apr. 24, 1986; CGD 89-025, 54 FR 19571, May 8, 1989; CGD 96-041, 61 FR 50730, Sept. 27, 1996; USCG-2000-7790, 65 FR 58461, Sept. 29, 2000; USCG-2007-29018, 72 FR 53966, Sept. 21, 2007; USCG-2008-0906, 73 FR 56510, Sept. 29, 2008; USCG-2009-0702, 74 FR 49233, Sept. 25, 2009; USCG-2013-0671, 78 FR 60151, Sept. 30, 2013; USCG-2016-0498, 82 FR 35091, July 28, 2017; USCG-2021-0348, 87 FR 3224, Jan. 21, 2022]