(a) EWIS that are part of each fire or overheat detector system in a fire zone must be fire-resistant.
(b) No EWIS component of any fire or overheat detector system for any fire zone may pass through another fire zone, unless:
(1) It is protected against the possibility of false warnings resulting from fires in zones through which it passes; or
(2) Each zone involved is simultaneously protected by the same detector and extinguishing system.
(c) EWIS that are part of each fire or overheat detector system in a fire zone must meet the requirements of § 25.1203.
source: Docket No. 5066, 29 FR 18291, Dec. 24, 1964, unless otherwise noted.
cite as: 14 CFR 25.1731