Regulations last checked for updates: Oct 18, 2024

Title 40 - Protection of Environment last revised: Oct 16, 2024
§ 467.22 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Subpart B Core
Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Maximum for monthly average
mg/off-kg (lb/million off-lbs) of aluminum rolled with emulsions
Chromium0.0570.024
Cyanide0.0380.016
Zinc0.190.079
Aluminum0.840.416
Oil and grease2.601.56
Suspended solids5.332.53
pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

Subpart B Direct Chill Casting Contact Cooling Water
Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Maximum for monthly average
mg/off-kg (lb/million off-lbs) of aluminum cast
Chromium0.590.24
Cyanide0.390.16
Zinc1.940.81
Aluminum8.554.26
Oil and grease26.5815.95
Suspended solids54.4925.92
pH( 1)( 1)

1 The pH shall be maintained within the range of 7.0 to 10.0 at all times except for those situations when this waste stream is discharged separately and without commingling with any other wastewater in which case the pH shall be within the range of 6.0 to 10.0 at all times.

Subpart B Solution Heat Treatment Contact Cooling Water
Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Maximum for monthly average
mg/off-kg (lb/million off-lbs) of aluminum quenched
Chromium3.391.39
Cyanide2.240.93
Zinc11.254.70
Aluminum49.5524.66
Oil and grease154.1092.46
Suspended solids315.91150.25
pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

Subpart B Cleaning or Etching Bath
Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Maximum for monthly average
mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched
Chromium0.0790.032
Cyanide0.0520.022
Zinc0.2620.109
Aluminum1.150.573
Oil and grease3.582.15
Suspended solids7.343.49
pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

Subpart B Cleaning or Etching Rinse
Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Maximum for monthly average
mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched
Chromium6.122.51
Cyanide4.041.67
Zinc20.318.49
Aluminum89.4644.52
Oil and grease278.24166.95
Suspended solids570.39271.29
pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

Subpart B Cleaning or Etching Scrubber Liquor
Pollutant or pollutant property BPT effluent limitations
Maximum for any 1 day Maximum for monthly average
mg/off-kg (lb/million off-lbs) of aluminum cleaned or etched
Chromium7.002.86
Cyanide4.611.91
Zinc23.229.70
Aluminum102.2450.88
Oil and grease318.00190.80
Suspended solids651.90310.05
pH( 1)( 1)

1 Within the range of 7.0 to 10.0 at all times.

[48 FR 49149, Oct. 24, 1983; 49 FR 11631, 11632, Mar. 27, 1984, as amended at 53 FR 52370, Dec. 27, 1988]
source: 48 FR 49149, Oct. 24, 1983, unless otherwise noted.
cite as: 40 CFR 467.22