Regulations last checked for updates: Nov 22, 2024

Title 42 - Public Health last revised: Nov 19, 2024
§ 84.122 - Breathing resistance test; minimum requirements.

(a) Resistance to airflow will be measured in the facepiece or mouthpiece of a gas mask mounted on a breathing machine both before and after each test conducted in accordance with §§ 84.124, 84.125, and 84.126, with air flowing at a continuous rate of 85 liters per minute.

(b) The maximum allowable resistance requirements for gas masks are as follows:

Maximum Resistance

[mm. water-column height]

Type of gas mask Inhalation Exhalation
Initial Final 1
Front-mounted or back-mounted (without particulate filter)607520
Front-mounted or back-mounted (with approved particulate filter)708520
Chin-style (without particulate filter)405520
Chin-style (with approved particulate filter)658020
Escape (without particulate filter)607520
Escape (with approved particulate filter)708520

1 Measured at end of the service life specified in Tables 5, 6, and 7 of this subpart.

authority: 29 U.S.C. 651
source: 60 FR 30355, June 8, 1995, unless otherwise noted.
cite as: 42 CFR 84.122