A remotely actuated quick closing shutoff valve required by § 153.530(n) must:
(a) Be a positive shutoff valve;
(b) Be of the fail-closed type that closes on loss of power;
(c) Be capable of local manual closing;
(d) Close from the time of actuation in 30 seconds or less; and
(e) Be equipped with a fusible element that melts at less than 104 °C (approx. 220 °F) and closes the valve.
[CGD 78-128, 47 FR 21208, May 17, 1982; 47 FR 27293, June 24, 1982]
authority: 46 U.S.C. 3703; Department of Homeland Security Delegation No. 0170.1. Section 153.40 issued under
49 U.S.C. 5103. Sections 153.470 through 153.491, 153.1100 through 153.1132, and 153.1600 through 153.1608 also issued under
33 U.S.C. 1903 (b)
source: CGD 73-96, 42 FR 49027, Sept. 26, 1977, unless otherwise noted.