§ 195.565 - How do I install cathodic protection on breakout tanks?

After October 2, 2000, when you install cathodic protection under § 195.563(a) to protect the bottom of an aboveground breakout tank of more than 500 barrels 79.49m3 capacity built to API Spec 12F (incorporated by reference, see § 195.3), API Std 620 (incorporated by reference, see § 195.3), API Std 650 (incorporated by reference, see § 195.3), or API Std 650's predecessor, Standard 12C, you must install the system in accordance with ANSI/API RP 651 (incorporated by reference, see § 195.3). However, you don't need to comply with API RP 651 when installing any tank for which you note in the corrosion control procedures established under § 195.402(c)(3) why complying with all or certain provisions of API RP 651 is not necessary for the safety of the tank.

[Amdt. 195-99, 80 FR 188, Jan. 5, 2015, as amended by Amdts. 192-135, 195-107, 89 FR 33284, Apr. 29, 2024]
authority: 30 U.S.C. 185(w)(3), 49 U.S.C. 5103,60101
source: Amdt. 195-22, 46 FR 38360, July 27, 1981, unless otherwise noted.
cite as: 49 CFR 195.565