(a) Frequency of testing. The compressor or compressors shall be tested for capacity by orifice test as often as conditions may require, but not less frequently than once every 92 service days.
(b) Orifice testing criteria. (1) Compressors in common use, as listed in the following table, shall have orifice test criteria as follows:
Make
| Compressor size
| Single strokes per minute
| Diameter of orifice
(in inches)
| Air pressure maintained
(in pounds)
|
---|
Westinghouse | 9
1/2 | 120 |
11/64 | 60
|
Westinghouse | 11 | 100 |
3/16 | 60
|
Westinghouse | 150 CFM 8
1/2 CC | 100 |
9/32 | 60
|
Westinghouse | 120 CFM 8
1/2 | 100 |
15/64 | 60
|
New York | 2a | 120 |
5/32 | 60
|
New York | 6a | 100 |
13/64 | 60
|
New York | 5b | 100 |
15/64 | 60
|
(2) For compressors not listed in the table in paragraph (b)(1) of this section, the air pressure to be maintained shall be no less than 80 percent of the manufacturer's rated capacity for the compressor.