Except as provided in §§ 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Effluent characteristic
| Effluent limitations
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days shall not exceed—
|
---|
| Metric units (q/sq m of product)
|
TSS | 1.95 | 1.22
|
Oil | 0.64 | .64
|
pH | (
1) | (
1)
|
| English units (lb/1,060 sq ft of product)
|
TSS | 0.40 | 0.25
|
Oil | 0.13 | .13
|
pH | (
1) | (
1)
|
[39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33959, June 29, 1995]
authority: Secs. 301, 304 (b) and (c), 306 (b) and (c), 307(c), and 316(b) of the Federal Water Pollution Control Act, as amended;
33 U.S.C. 1251,
1311,
1314,
1316,
1317; 86 Stat. 816
source: 39 FR 2565, Jan. 22, 1974, unless otherwise noted.
cite as: 40 CFR 426.62