This subpart applies to discharges to waters of the United States and introduction of pollutants into publicly owned treatment works resulting from the production of hydrogen cyanide by the Andrussow process.
For the purposes of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term product means hydrogen cyanide.
(c) The term Cyanide A means those cyanides amenable to chlorination and is determined by the methods specified in 40 CFR 136.3.
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
Subpart AP—Hydrogen Cyanide
Pollutant or pollutant property
| BPT effluent limitations
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (or pounds per 1,000 lb) of product
|
TSS | 8.6 | 3.2
|
Cyanide A | 0.10 | 0.021
|
Total Cyanide | 0.65 | 0.23
|
pH | (
1) | (
1)
|
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):
Subpart AP—Hydrogen Cyanide
Pollutant or pollutant property
| BAT effluent limitations
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (or pounds per 1,000 lb) of product
|
Cyanide A | 0.10 | 0.021
|
Total Cyanide | 0.65 | 0.23
|
Total Residual Chlorine | 0.086 | 0.051 |
Any new source subject to this subpart must achieve the following new source performance standards (NSPS):
Subpart AP—Hydrogen Cyanide
Pollutant or pollutant property
| NSPS effluent limitations
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (or pounds per 1,000 lb) of product
|
TSS | 8.6 | 3.2
|
Cyanide A | 0.10 | 0.021
|
Total Cyanide | 0.65 | 0.23
|
Total Residual Chlorine | 0.086 | 0.051
|
Ph | (
1) | (
1)
|
Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following Pretreatment Standards for New Sources (PSNS):
Subpart AP—Hydrogen Cyanide
Pollutant or pollutant property
| PSNS effluent limitations
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Milligrams per liter
|
Cyanide A | 1.7 | 0.36
|
Total Cyanide | 11 | 4.0 |
In cases where POTWs find it necessary to impose mass limitations, the following equivalent mass limitations are provided as an alternate: The limitations for Cyanide A and Total Cyanide are the same as specified in § 415.425.
[47 FR 55227, Dec. 8, 1982]
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT): The limitations are the same for TSS and pH as specified in § 415.422.
authority: Secs. 301, 304 (b), (c), (e), and (g), 306 (b) and (c), 307 (b) and (c), and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972, as amended by the Clean Water Act of 1977) (the “Act”);
33 U.S.C. 1311,
1314,
c,
e,
and, 1316 (b) and
c, 1317 (b) and
c,
and; 86 Stat. 816, Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217
source: 47 FR 28278, June 29, 1982, unless otherwise noted.
cite as: 40 CFR 415.425