The provisions of this subpart are applicable to discharges and to the introduction of pollutants into publicly owned treatment works resulting from ironmaking operations in which iron ore is reduced to molten iron in a blast furnace.
(a) For ironmaking blast furnaces, the term product means the amount of molten iron produced.
(b) The term molten iron means iron produced in a blast furnace as measured at the blast furnace, and may include relatively minor amounts of blast furnace slag that may be skimmed from the molten iron at the steelmaking shop or other location remote from the blast furnace.
(c) The term iron blast furnace means all blast furnaces except ferromanganese blast furnaces.
(d) The term existing indirect dischargers means only those two iron blast furnace operations with discharges to publicly owned treatment works prior to May 27, 1982.
[67 FR 64266, Oct. 17, 2002]
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
(a) Iron blast furnace.
Pollutant or pollutant property
| BPT effluent limitations
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (pounds per 1,000 lb) of product
|
TSS | 0.0782 | 0.0260
|
Ammonia-N | 0.161 | 0.0537
|
Cyanide | 0.0234 | 0.00782
|
Phenols (4AAP) | 0.00626 | 0.00210
|
pH | (
1) | (
1)
|
(b) [Reserved]
[47 FR 23284, May 27, 1982; 47 FR 41739, Sept. 22, 1982, as amended at 67 FR 64266, Oct. 17, 2002]
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
(a) Iron blast furnace.
Pollutant or pollutant property
| BAT effluent limitations
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (pounds per 1,000 lb) of product
|
Ammonia-N | 0.00876 | 0.00292
|
Cyanide | 0.00175 | 0.000876
|
Phenols (4AAP) | 0.0000584 | 0.0000292
|
TRC
1 | 0.000146 | |
Lead | 0.000263 | 0.0000876
|
Zinc | 0.000394 | 0.000131
|
(b) [Reserved]
[47 FR 23284, May 27, 1982; 47 FR 41739, Sept. 22, 1982, as amended at 49 FR 21030, May 17, 1984; 67 FR 64266, Oct. 17, 2002]
The discharge of wastewater pollutants from any new source subject to this subpart shall not exceed the standards set forth below.
(a) Iron blast furnace.
Pollutant or pollutant property
| New source performance standards
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (pounds per 1,000 lb) of products
|
TSS | 0.0117 | 0.00438
|
O&G | 0.00292 | |
Ammonia-N | 0.00876 | 0.00292
|
Cyanide | 0.000584 | 0.000292
|
Phenols (4AAP) | 0.0000584 | 0.0000292
|
TRC
1 | 0.000146 | |
Lead | 0.000263 | 0.0000876
|
Zinc | 0.000394 | 0.000131
|
pH | (
2) | (
2)
|
(b) [Reserved]
[47 FR 23284, May 27, 1982; 47 FR 41739, Sept. 22, 1982, as amended at 49 FR 21030, May 17, 1984; 67 FR 64266, Oct. 17, 2002]
Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources.
(a) Iron blast furnace.
Pollutant or pollutant property
| Pretreatment standards for existing sources
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (pounds per 1,000 lb) of products
|
Ammonia-N
1 | 0.00876 | 0.00292
|
Cyanide | 0.00175 | 0.000876
|
Phenols (4AAP) | 0.0000584 | 0.0000292
|
Lead | 0.000263 | 0.0000876
|
Zinc | 0.000394 | 0.000131
|
(b) [Reserved]
(c) Existing indirect dischargers.
Pollutant or pollutant property
| Pretreatment standards for existing sources
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (pounds per 1,000 lb) of product
|
Ammonia-N | 0.0350 | 0.0175
|
Cyanide | 0.00175 | 0.000876
|
Phenols (4AAP) | 0.000175 | 0.0000584
|
Lead | 0.000263 | 0.0000876
|
Zinc | 0.000394 | 0.000131 |
[47 FR 23284, May 27, 1982, as amended at 49 FR 21030, May 17, 1984; 67 FR 64266, Oct. 17, 2002]
Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources.
(a) Iron blast furnace.
Pollutant or pollutant property
| Pretreatment standards for new sources
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (pounds per 1,000 lb) of product
|
Ammonia-N
1 | 0.00876 | 0.00292
|
Cyanide | 0.000584 | 0.000292
|
Phenols (4AAP) | 0.0000584 | 0.0000292
|
Lead | 0.000263 | 0.0000876
|
Zinc | 0.000394 | 0.000131
|
(b) [Reserved]
[47 FR 23284, May 27, 1982, as amended at 49 FR 21030, May 17, 1984; 67 FR 64267, Oct. 17, 2002]