Regulations last checked for updates: Nov 22, 2024
Title 40 - Protection of Environment last revised: Nov 20, 2024
§ 465.40 - Applicability; description of the canmaking subcategory.
This subpart applies to discharges to waters of the United States, and introductions of pollutants into publicly owned treatment works from the manufacturing of seamless can bodies, which are washed.
§ 465.41 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available:
Subpart D—BPT Effluent Limitations
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| g (lbs)/1,000,000 cans manufactured
|
Cr | 94.60 (0.209) | 38.70 (0.085)
|
Zn | 313.90 (0.692) | 131.15 (0.289)
|
Al | 1382.45 (3.048) | 688.00 (1.517)
|
F | 12792.50 (28.203) | 5676.00 (12.514)
|
P | 3590.50 (7.916) | 1468.45 (3.237)
|
O & G | 4300.00 (9.480) | 2580.00 (5.688)
|
TSS | 8815.00 (19.434) | 4192.50 (9.243)
|
pH | (
1) | (
1)
|
[48 FR 52399, Nov. 17, 1983; 49 FR 14105, Apr. 10, 1984]
§ 465.42 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable:
Subpart D—BAT Effluent Limitations
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| g (lbs)/1,000,000 cans manufactured
|
Cr | 36.92 (0.081) | 15.10 (0.033)
|
Zn | 122.49 (0.270) | 51.18 (0.113)
|
Al | 539.48 (1.189) | 268.48 (0.592)
|
F | 4992.05 (11.001) | 2214.96 (4.883)
|
P | 1401.13 (3.089) | 573.04 (1.263) |
§ 465.43 - New source performance standards.
The following standards of performance establish the quantity of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| g (lbs)/1,000,000 cans manufactured
|
Cr | 27.98 (0.062) | 11.45 (0.025)
|
Zn | 92.86 (0.205) | 38.80 (0.086)
|
Al | 408.95 (0.902) | 203.52 (0.449)
|
F | 3784.20 (8.343) | 1679.04 (3.702)
|
P | 1062.12 (2.342) | 434.39 (0.958)
|
O & G | 1272.00 (2.804) | 763.20 (1.683)
|
TSS | 2607.60 (5.749) | 1240.20 (2.734)
|
pH | (
1) | (
1)
|
[48 FR 52399, Nov. 17, 1983; 49 FR 14105, Apr. 10, 1984]
§ 465.44 - Pretreatment standards for existing sources.
Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for exisiting sources.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| g (lbs)/1,000,000 cans manufactured
|
Cr | 36.92 (0.081) | 15.10 (0.033)
|
Cu | 159.41 (0.351) | 83.90 (0.185)
|
Zn | 122.49 (0.270) | 51.18 (0.113)
|
F | 4992.05 (11.001) | 2214.96 (4.883)
|
P | 1401.13 (3.089) | 573.04 (1.263)
|
Mn | 57.05 (0.126) | 24.33 (0.053)
|
TTO | 26.85 (0.059) | 12.59 (0.028)
|
O&G (for alternate monitoring) | 1678.00 (3.699) | 1006.80 (2.220) |
[48 FR 52399, Nov. 17, 1983; 49 FR 14105, Apr. 10, 1984]
§ 465.45 - Pretreatment standards for new sources.
Except as provided in 40 CFR 403.7 any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| g (lbs)/1,000,000 cans manufactured
|
Cr | 27.98 (0.0617) | 11.45 (0.025)
|
Cu | 120.84 (0.267) | 63.60 (0.140)
|
Zn | 92.86 (0.205) | 38.80 (0.086)
|
F | 3784.20 (8.345) | 1679.04 (3.702)
|
P | 1062.12 (2.342) | 434.39 (0.958)
|
Mn | 43.25 (0.095) | 18.44 (0.041)
|
TTO | 20.35 (0.045) | 9.54 (0.0210)
|
O&G (for alternate monitoring) | 1272.00 (2.804) | 763.20 (1.683) |
[48 FR 52399, Nov. 17, 1983; 49 FR 14105, Apr. 10, 1984]
§ 465.46 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology. [Reserved]
authority: Secs. 301, 304 (b), (c), (e), and (g), 306 (b) and (c), 307 (b) and (c), and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972, as amended by the Clean Water Act of 1977) (the “Act”);
33 U.S.C. 1311,
1314,
c,
e,
and, 1316 (b) and
c, 1317 (b) and
c,
and; 86 Stat. 816, Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217
source: 47 FR 54244, Dec. 1, 1982, unless otherwise noted.
cite as: 40 CFR 465.40