Regulations last checked for updates: Nov 22, 2024
Title 40 - Protection of Environment last revised: Nov 20, 2024
§ 471.30 - Applicability; description of the nickel-cobalt forming subcategory.
This subpart applies to discharges of pollutants to waters of the United States, and introductions of pollutants into publicly owned treatment works from the process operations of the nickel-cobalt forming subcategory.
§ 471.31 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).
Except as provided in 40 CFR 125.30-125.32, any existing point source sub-
ject to this subpart must achieve the following effluent limitations for the process operations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) Rolling spent neat oils—subpart C—BPT. There shall be no discharge of process wastewater pollutants.
(b) Rolling spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with emulsions
|
Chromium | 0.075 | 0.031
|
Nickel | 0.327 | 0.216
|
Fluoride | 10.1 | 4.49
|
Oil and grease | 3.4 | 2.04
|
TSS | 6.97 | 3.32
|
pH | (
1) | (
1)
|
(c) Rolling contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with water
|
Chromium | 1.66 | 0.679
|
Nickel | 7.24 | 4.79
|
Fluoride | 225 | 99.6
|
Oil and grease | 75.4 | 45.3
|
TSS | 155 | 73.5
|
pH | (
1) | (
1)
|
(d) Tube Reducing Spent Lubricant—subpart C—BPT. (1) There shall be no discharge of process wastewater pollutants except as provided under paragraph (d)(2) of this section.
(2) Process wastewater pollutants may be discharged, with no allowance for any pollutants discharged, provided the facility owner or operator demonstrates, on the basis of analytical methods set forth in or approved pursuant to 40 CFR part 136, that the concentrations of nitrosamine compounds in the wastewater discharged from the tube reducing process do not exceed 0.050 mg/l of N-nitrosodimethylamine, 0.020 mg/l of N-nitrosodiphenylamine, and 0.020 mg/l of N-nitrosodi-n-propylamine.
(3) The demonstration required under paragraph (d)(2) of this section shall be made once per month until the demonstration has been made for all three nitrosamine compounds for six consecutive months, after which time the demonstration may be made once per quarter. If a sample is found to contain any of the foregoing nitrosamine compounds at concentrations greater than those specified in paragraph (d)(2) of this section, the actions described in paragraph (d)(4) of this section shall be taken, and the demonstration required under paragraph (d)(2) of this section shall be made once per month until it has been made for all three nitrosamine compounds for six consecutive months.
(4) If sampling results show that any of the foregoing nitrosamine compounds is present in the process wastewater at concentrations greater than those specified in paragraph (d)(2) of this section, the facility owner or operator shall ensure that, within thirty days of receiving written notification of the sampling results, there is no further discharge of tube reducing spent lubricant wastewater until the owner or operator:
(i) Performs a subsequent analysis which demonstrates that the concentrations of the foregoing nitrosamine compounds do not exceed the levels specified in paragraph (d)(2) of this section; or
(ii) Substitutes a new tube reducing lubricant and thereafter complies with the requirements of paragraph (d)(3) of this section; or
(iii) Determines the source of the pollutant whose concentration exceeded the level specified in paragraph (d)(2) of this section and demonstrates to the satisfaction of the NPDES issuing authority that such source has been eliminated.
(5) The concentration limits specified in paragraph (d)(2) of this section apply at the point of discharge from the tube reducing process. However, sampling after the tube reducing wastewater has been commingled with other wastewaters is permitted if:
(i) Any dilution caused by the other wastewaters is taken into account in determining the appropriate (i.e., lower) allowable discharge concentration; and
(ii) An analytical method of sufficient sensitivity is used to measure the levels of each of the foregoing nitrosamine compounds in the wastewaters being sampled.
(e) Drawing spent neat oils—subpart C—BPT. There shall be no discharge of process wastewater pollutants
(f) Drawing spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt drawn with emulsions
|
Chromium | 0.042 | 0.017
|
Nickel | 0.183 | 0.121
|
Fluoride | 5.68 | 2.52
|
Oil and grease | 1.91 | 1.15
|
TSS | 3.91 | 1.86
|
pH | (
1) | (
1)
|
(g) Extrusion spent lubricants—subpart C—BPT. There shall be no discharge of process wastewater pollutants.
(h) Extrusion press or solution heat treatment contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt heat treated
|
Chromium | 0.037 | 0.015
|
Nickel | 0.160 | 0.106
|
Fluoride | 4.95 | 2.20
|
Oil and grease | 1.67 | 0.999
|
TSS | 3.41 | 1.63
|
pH | (
1) | (
1)
|
(i) Extrusion press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt extruded
|
Chromium | 0.102 | 0.042
|
Nickel | 0.446 | 0.295
|
Fluoride | 13.8 | 6.13
|
Oil and grease | 4.64 | 2.79
|
TSS | 9.51 | 4.53
|
pH | (
1) | (
1)
|
(j) Forging equipment cleaning wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.018 | 0.007
|
Nickel | 0.077 | 0.051
|
Fluoride | 2.38 | 1.06
|
Oil and grease | 0.800 | 0.480
|
TSS | 1.640 | 0.780
|
pH | (
1) | (
1)
|
(k) Forging contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of forged nickel-cobalt cooled with water
|
Chromium | 0.209 | 0.086
|
Nickel | 0.910 | 0.602
|
Fluoride | 28.2 | 12.5
|
Oil and grease | 9.48 | 5.69
|
TSS | 19.5 | 9.25
|
pH | (
1) | (
1)
|
(l) Forging press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.083 | 0.034
|
Nickel | 0.359 | 0.238
|
Fluoride | 11.2 | 4.94
|
Oil and grease | 3.74 | 2.25
|
TSS | 7.67 | 3.65
|
pH | (
1) | (
1)
|
(m) Forging spent lubricants—subpart C—BPT. There shall be no discharge of process wastewater pollutants.
(n) Stationary casting contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt cast with stationary casting methods
|
Chromium | 5.33 | 2.18
|
Nickel | 23.3 | 15.4
|
Fluoride | 720 | 320
|
Oil and grease | 242 | 145
|
TSS | 496 | 236
|
pH | (
1) | (
1)
|
(o) Vacuum melting steam condensate—subpart C—BPT. There shall be no allowance for the discharge of process wastewater pollutants.
(p) Metal powder production atomization wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt metal powder atomized
|
Chromium | 1.16 | 0.472
|
Nickel | 5.03 | 3.33
|
Fluoride | 156 | 69.2
|
Oil and grease | 52.4 | 31.5
|
TSS | 108 | 51.1
|
pH | (
1) | (
1)
|
(q) Annealing and solution heat treatment contact cooling water—subpart C—BPT. There shall be no allowance for the discharge of process wastewater pollutants.
(r) Wet air pollution control scrubber blowdown.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.357 | 0.146
|
Nickel | 1.56 | 1.03
|
Fluoride | 48.2 | 21.4
|
Oil and grease | 16.2 | 9.72
|
TSS | 33.2 | 15.8
|
pH | (
1) | (
1)
|
(s) Surface treatment spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 0.412 | 0.169
|
Nickel | 1.80 | 1.19
|
Fluoride | 55.7 | 24.7
|
Oil and grease | 18.7 | 11.2
|
TSS | 38.4 | 18.3
|
pH | (
1) | (
1)
|
(t) Surface treatment rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 10.4 | 4.25
|
Nickel | 45.3 | 30.0
|
Fluoride | 1410 | 623
|
Oil and grease | 472 | 283
|
TSS | 968 | 460
|
pH | (
1) | (
1)
|
(u) Alkaline cleaning spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 0.015 | 1.52
|
Nickel | 16.2 | 10.7
|
Fluoride | 502 | 223
|
Oil and grease | 169 | 101
|
TSS | 346 | 165
|
pH | (
1) | (
1)
|
(v) Alkaline cleaning rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 1.03 | 0.420
|
Nickel | 4.48 | 2.96
|
Fluoride | 139 | 61.5
|
Oil and grease | 46.6 | 28.0
|
TSS | 95.6 | 45.5
|
pH | (
1) | (
1)
|
(w) Molten salt rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with molten salt
|
Chromium | 3.72 | 1.52
|
Nickel | 16.2 | 10.7
|
Fluoride | 502 | 223
|
Oil and grease | 169 | 101
|
TSS | 346 | 165
|
pH | (
1) | (
1)
|
(x) Ammonia rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with ammonia solution
|
Chromium | 0.007 | 0.003
|
Nickel | 0.029 | 0.019
|
Fluoride | 0.881 | 0.391
|
Oil and grease | 0.296 | 0.178
|
TSS | 0.607 | 0.289
|
pH | | (
1)
|
(y) Sawing or grinding spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt sawed or ground with emulsions
|
Chromium | 0.018 | 0.007
|
Nickel | 0.076 | 0.050
|
Fluoride | 2.35 | 1.04
|
Oil and grease | 0.788 | 0.473
|
TSS | 1.62 | 0.769
|
pH | | (
1)
|
(z) Sawing or grinding rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of sawed or ground nickel-cobalt rinsed
|
Chromium | 0.797 | 0.326
|
Nickel | 3.48 | 2.30
|
Fluoride | 108 | 47.8
|
Oil and grease | 36.2 | 21.7
|
TSS | 74.2 | 35.3
|
pH | | (
1)
|
(aa) Steam Cleaning Condensate.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt steam cleaned
|
Chromium | 0.013 | 0.006
|
Nickel | 0.058 | 0.039
|
Fluoride | 1.79 | 0.795
|
Oil and grease | 0.602 | 0.361
|
TSS | 1.24 | 0.587
|
pH | | (
1)
|
(bb) Hydrostatic tube testing and ultrasonic testing wastewater—subpart C—BPT. There shall be no allowance for the discharge of process wastewater pollutants.
(cc) Degreasing spent solvents—subpart C—BPT. There shall be no discharge of process wastewater pollutants.
(dd) Dye penetrant testing wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt tested with dye penetrant method
|
Chromium | 0.094 | 0.039
|
Nickel | 0.409 | 0.271
|
Fluoride | 12.7 | 5.63
|
Oil and grease | 4.26 | 2.56
|
TSS | 8.74 | 4.16
|
pH | (
1) | (
1)
|
(ee) Electrocoating rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt electrocoated
|
Chromium | 1.48 | 0.607
|
Nickel | 6.47 | 4.28
|
Fluoride | 201 | 89.0
|
Oil and grease | 67.4 | 40.5
|
TSS | 138 | 65.7
|
pH | (
1) | (
1)
|
(ff) Miscellaneous wastewater sources.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.108 | 0.044
|
Nickel | 0.473 | 0.313
|
Fluoride | 14.7 | 6.50
|
Oil and grease | 4.92 | 2.95
|
TSS | 10.1 | 4.80
|
pH | (
1) | (
1)
|
[50 FR 34270, Aug. 23, 1985; 51 FR 2884, Jan. 22, 1986, as amended at 54 FR 11348, Mar. 17, 1989]
§ 471.32 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT).
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT):
(a) Rolling spent neat oils—subpart C—BAT. There shall be no discharge of process wastewater pollutants.
(b) Rolling spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with emulsions
|
Chromium | 0.063 | 0.026
|
Nickel | 0.094 | 0.063
|
Fluoride | 10.1 | 4.49 |
(c) Rolling contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with water
|
Chromium | 0.028 | 0.011
|
Nickel | 0.042 | 0.028
|
Fluoride | 4.49 | 1.99 |
(d) Tube Reducing Spent Lubricant—subpart C—BAT. (1) There shall be no discharge of process wastewater pollutants except as provided under paragraph (d)(2) of this section.
(2) Process wastewater pollutants may be discharged, with no allowance for any pollutants discharged, provided the facility owner or operator demonstrates, on the basis of analytical methods set forth in or approved pursuant to 40 CFR part 136, that the concentrations of nitrosamine compounds in the wastewater discharged from the tube reducing process do not exceed 0.050 mg/l of N-nitrosodimethylamine, 0.020 mg/l of N-nitrosodiphenylamine, and 0.020 mg/l of N-nitrosodi-n-propylamine.
(3) The demonstration required under paragraph (d)(2) of this section shall be made once per month until the demonstration has been made for all three nitrosamine compounds for six consecutive months, after which time the demonstration may be made once per quarter. If a sample is found to contain any of the foregoing nitrosamine compounds at concentrations greater than those specified in subparagraph (d)(2) of this section, the actions described in paragraph (d)(4) of this section shall be taken, and the demonstration required under subparagraph (d)(2) of this section shall be made once per month until it has been made for all three nitrosamine compounds for six consecutive months.
(4) If sampling results show that any of the foregoing nitrosamine compounds is present in the process wastewater at concentrations greater than those specified in subparagraph (d)(2) of this section, the facility owner or operator shall ensure that, within thirty days of receiving written notification of the sampling results, there is no further discharge of tube reducing spent lubricant wastewater until the owner or operator:
(i) Performs a subsequent analysis which demonstrates that the concentrations of the foregoing nitrosamine compounds do not exceed the levels specified in paragraph (d)(2) of this section; or
(ii) Substitutes a new tube reducing lubricant and thereafter complies with the requirements of paragraph (d)(3) of this section; or
(iii) Determines the source of the pollutant whose concentration exceeded the level specified in paragraph (d)(2) of this section and demonstrates to the satisfaction of the NPDES issuing authority that such source has been eliminated.
(5) The concentration limits specified in paragraph (d)(2) of this section apply at the point of discharge from the tube reducing process. However, sampling after the tube reducing wastewater has been commingled with other wastewaters is permitted if:
(i) Any dilution caused by the other wastewaters is taken into account in determining the appropriate (i.e., lower) allowable discharge concentration; and
(ii) An analytical method of sufficient sensitivity is used to measure the levels of each of the foregoing nitrosamine compounds in the wastewaters being sampled.
(e) Drawing spent neat oils—subpart C—BAT. There shall be no discharge of process wastewater pollutants.
(f) Drawing spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt drawn with emulsions
|
Chromium | 0.036 | 0.015
|
Nickel | 0.053 | 0.036
|
Fluoride | 5.68 | 2.52 |
(g) Extrusion spent lubricants—subpart C—BAT. There shall be no discharge of process wastewater pollutants.
(h) Extrusion press or solution heat treatment contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of extruded nickel-cobalt heat treated
|
Chromium | 0.031 | 0.013
|
Nickel | 0.046 | 0.031
|
Fluoride | 4.95 | 2.20 |
(i) Extrusion press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt extruded
|
Chromium | 0.086 | 0.034
|
Nickel | 0.128 | 0.086
|
Fluoride | 13.8 | 6.13 |
(j) Forging equipment cleaning wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.002 | 0.0006
|
Nickel | 0.002 | 0.002
|
Fluoride | 0.238 | 0.106 |
(k) Forging contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of forged nickel-cobalt cooled with water
|
Chromium | 0.018 | 0.007
|
Nickel | 0.026 | 0.018
|
Fluoride | 2.82 | 1.25 |
(l) Forging press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.069 | 0.028
|
Nickel | .103 | 0.069
|
Fluoride | 11.2 | 4.94 |
(m) Forging spent lubricants—subpart C—BAT. There shall be no discharge of process wastewater pollutants.
(n) Stationary casting contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt cast with stationary casting methods
|
Chromium | 0.448 | 0.182
|
Nickel | .666 | .448
|
Fluoride | 72.0 | 32.0 |
(o) Vacuum melting steam condensate—subpart C—BAT. There shall be no allowance for the discharge of wastewater pollutants.
(p) Metal powder production atomization wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt metal powder atomized
|
Chromium | 0.970 | 0.393
|
Nickel | 1.44 | .970
|
Fluoride | 156 | 69.2 |
(q) Annealing and solution heat treatment contact cooling water—subpart C—BAT. There shall be no allowance for the discharge of wastewater pollutants.
(r) Wet air pollution control scrubber blowdown.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.300 | 0.122
|
Nickel | .446 | .300
|
Fluoride | 48.2 | 21.4 |
(s) Surface treatment spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 0.346 | 0.141
|
Nickel | .514 | .346
|
Fluoride | 55.7 | 24.7 |
(t) Surface treatment rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 0.873 | 0.354
|
Nickel | 1.30 | .873
|
Fluoride | 141 | 62.3 |
(u) Alkaline cleaning spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 0.013 | 0.005
|
Nickel | 0.019 | 0.013
|
Fluoride | 2.02 | 0.895 |
(v) Alkaline cleaning rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 0.086 | 0.035
|
Nickel | 0.128 | 0.086
|
Fluoride | 13.9 | 6.15 |
(w) Molten salt rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly averge
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with molten salt
|
Chromium | 0.312 | 0.127
|
Nickel | 0.464 | 0.312
|
Fluoride | 50.2 | 22.3 |
(x) Ammonia rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with ammonia solution
|
Chromium | 0.006 | 0.002
|
Nickel | 0.008 | 0.006
|
Fluoride | 0.881 | 0.391 |
(y) Sawing or grinding spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt sawed or ground with emulsions
|
Chromium | 0.015 | 0.006
|
Nickel | 0.022 | 0.015
|
Fluoride | 2.35 | 1.04 |
(z) Sawing or grinding rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of sawed or ground nickel-cobalt rinsed
|
Chromium | 0.067 | 0.027
|
Nickel | 0.100 | 0.067
|
Fluoride | 10.8 | 4.78 |
(aa) Steam cleaning condensate.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt steam cleaned
|
Chromium | 0.011 | 0.005
|
Nickel | 0.017 | 0.011
|
Fluoride | 1.79 | 0.795 |
(bb) Hydrostatic tube testing and ultrasonic testing wastewater—subpart C—BAT. There shall be no allowance for the discharge of process wastewater pollutants.
(cc) Degreasing spent solvents—subpart C—BAT. There shall be no discharge of process wastewater pollutants.
(dd) Dye penetrant testing wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt tested with dye penetrant method
|
Chromium | 0.079 | 0.032
|
Nickel | 0.117 | 0.079
|
Fluoride | 12.7 | 5.63 |
(ee) Electrocoating rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt electrocoated
|
Chromium | 1.25 | 0.506
|
Nickel | 1.86 | 1.25
|
Fluoride | 201 | 89.0 |
(ff) Miscellaneous wastewater sources.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.091 | 0.037
|
Nickel | 0.136 | 0.091
|
Fluoride | 14.7 | 6.50 |
[50 FR 34270, Aug. 23, 1985; 51 FR 2885, Jan. 22, 1986, as amended at 54 FR 11348, Mar. 17, 1989; 54 FR 13606, Apr. 4, 1989]
§ 471.33 - New source performance standards (NSPS).
Any new source subject to this subpart must achieve the following new source performance standards (NSPS). The mass of pollutants in the nickel-cobalt forming process wastewater shall not exceed the following values:
(a) Rolling spent neat oils—subpart C—NSPS. There shall be no discharge of process wastewater pollutants.
(b) Rolling spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with emulsions
|
Chromium | 0.063 | 0.026
|
Nickel | 0.094 | 0.063
|
Fluoride | 10.1 | 4.49
|
Oil and grease | 1.70 | 1.70
|
TSS | 2.55 | 2.04
|
pH | (
1) | (
1)
|
(c) Rolling contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with water
|
Chromium | 0.028 | 0.012
|
Nickel | 0.042 | 0.028
|
Fluoride | 4.49 | 1.99
|
Oil and grease | 0.754 | 0.754
|
TSS | 1.13 | 0.905
|
pH | (
1) | (
1)
|
(d) Tube Reducing Spent Lubricant—subpart C—NSPS. (1) There shall be no discharge of process wastewater pollutants except as provided under paragraph (d)(2) of this section.
(2) Process wastewater pollutants may be discharged, with no allowance for any pollutants discharged, provided the facility owner or operator demonstrates, on the basis of analytical methods set forth in or approved pursuant to 40 CFR part 136, that the concentrations of nitrosamine compounds in the wastewater discharged from the tube reducing process do not exceed 0.050mg/l of N-nitrosodimethylamine, 0.020 mg/l of N-nitrosodiphenylamine, and 0.020 mg/l of N-nitrosodi-n-propylamine.
(3) The demonstration required under paragraph (d)(2) of this section shall be made once per month until the demonstration has been made for all three nitrosamine compounds for six consecutive months, after which time the demonstration may be made once per quarter. If a sample is found to contain any of the foregoing nitrosamine compounds at concentrations greater than those specified in paragraph (d)(2) of this section, the actions described in paragraph (d)(4) of this section shall be taken, and the demonstration required under paragraph (d)(2) of this section shall be made once per month until it has been made for all three nitrosamine compounds for six consecutive months.
(4) If sampling results show that any of the foregoing nitrosamine compounds is present in the process wastewater at concentrations greater than those specified in paragraph (d)(2) of this section, the facility owner or operator shall ensure that, within thirty days of receiving written notification of the sampling results, there is no further discharge of tube reducing spent lubricant wastewater until the owner or operator:
(i) Performs a subsequent analysis which demonstrates that the concentrations of the foregoing nitrosamine compounds do not exceed the levels specified in paragraph (d)(2) of this section; or
(ii) Substitutes a new tube reducing lubricant and thereafter complies with the requirements of paragraph (d)(3) of this section; or
(iii) Determines the source of the pollutant whose concentration exceeded the level specified in paragraph (d)(2) of this section and demonstrates to the satisfaction of the NPDES issuing authority that such source has been eliminated.
(5) The concentration limits specified in paragraph (d)(2) of this section apply at the point of discharge from the tube reducing process. However, sampling after the tube reducing wastewater has been commingled with other wastewaters is permitted if:
(i) Any dilution caused by the other wastewaters is taken into account in determining the appropriate (i.e., lower) allowable discharge concentration; and
(ii) An analytical method of sufficient sensitivity is used to measure the levels of each of the foregoing nitrosamine compounds in the wastewaters being sampled.
(e) Drawing spent neat oils—subpart C—NSPS. There shall be no discharge of process wastewater pollutants.
(f) Drawing spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt drawn with emulsions
|
Chromium | 0.036 | 0.015
|
Nickel | 0.053 | 0.036
|
Fluoride | 5.68 | 2.52
|
Oil and grease | 0.954 | 0.954
|
TSS | 1.43 | 1.15
|
pH | (
1) | (
1)
|
(g) Extrusion spent lubricants—subpart C—NSPS. There shall be no discharge of process wastewater pollutants.
(h) Extrusion press or solution heat treatment contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of extruded nickel-cobalt heat treated
|
Chromium | 0.031 | 0.013
|
Nickel | 0.046 | 0.031
|
Fluoride | 4.95 | 2.20
|
Oil and grease | 0.832 | 0.832
|
TSS | 1.25 | 0.999
|
pH | (
1) | (
1)
|
(i) Extrusion press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt extruded
|
Chromium | 0.086 | 0.035
|
Nickel | 0.128 | 0.086
|
Fluoride | 13.8 | 6.13
|
Oil and grease | 2.32 | 2.32
|
TSS | 3.48 | 2.79
|
pH | (
1) | (
1)
|
(j) Forging equipment cleaning wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.002 | 0.00006
|
Nickel | 0.002 | 0.002
|
Fluoride | 0.238 | 0.106
|
Oil and grease | 0.040 | 0.040
|
TSS | 0.060 | 0.048
|
pH | (
1) | (
1)
|
(k) Forging contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of forged nickel-cobalt cooled with water
|
Chromium | 0.018 | 0.007
|
Nickel | 0.026 | 0.018
|
Fluoride | 2.82 | 1.25
|
Oil and grease | 0.474 | 0.474
|
TSS | 0.711 | 0.569
|
pH | (
1) | (
1)
|
(l) Forging press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.069 | 0.028
|
Nickel | 0.103 | 0.069
|
Fluoride | 11.2 | 4.94
|
Oil and grease | 1.87 | 1.87
|
TSS | 2.81 | 2.25
|
pH | (
1) | (
1)
|
(m) Forging spent lubricants—subpart C—NSPS. There shall be no discharge of process wastewater pollutants.
(n) Stationary casting contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt cast with stationary casting methods
|
Chromium | 0.448 | 0.182
|
Nickel | 0.666 | 0.448
|
Fluoride | 72.0 | 32.0
|
Oil and grease | 12.1 | 12.1
|
TSS | 18.2 | 14.5
|
pH | (
1) | (
1)
|
(o) Vacuum melting steam condensate—subpart C—NSPS. There shall be no allowance for the discharge of process wastewater pollutants.
(p) Metal powder production atomization wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt metal powder atomized
|
Chromium | 0.970 | 0.393
|
Nickel | 1.44 | 0.970
|
Fluoride | 156 | 69.2
|
Oil and grease | 26.2 | 26.2
|
TSS | 39.3 | 31.5
|
pH | (
1) | (
1)
|
(q) Annealing and solution heat treatment contact cooling water—subpart C—NSPS. There shall be no allowance for the discharge of process wastewater pollutants.
(r) Wet air pollution control scrubber blowdown.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.300 | 0.122
|
Nickel | 0.450 | 0.300
|
Fluoride | 48.2 | 21.4
|
Oil and grease | 8.1 | 8.1
|
TSS | 12.2 | 9.72
|
pH | (
1) | (
1)
|
(s) Surface treatment spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 0.346 | 0.141
|
Nickel | 0.515 | 0.346
|
Fluoride | 55.7 | 24.7
|
Oil and grease | 9.35 | 9.35
|
TSS | 14.1 | 11.2
|
pH | (
1) | (
1)
|
(t) Surface treatment rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 0.874 | 0.354
|
Nickel | 1.30 | 0.873
|
Fluoride | 141 | 62.3
|
Oil and grease | 23.6 | 23.6
|
TSS | 35.4 | 28.3
|
pH | (
1) | (
1)
|
(u) Alkaline cleaning spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 0.013 | 0.005
|
Nickel | 0.019 | 0.013
|
Fluoride | 2.02 | 0.895
|
Oil and grease | 0.339 | 0.339
|
TSS | 0.509 | 0.407
|
pH | (
1) | (
1)
|
(v) Alkaline cleaning rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 0.086 | 0.035
|
Nickel | .128 | .086
|
Fluoride | 13.9 | 6.15
|
Oil and grease | 2.33 | 2.33
|
TSS | 3.50 | 2.80
|
pH | (
1) | (
1)
|
(w) Molten salt rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with molten salt
|
Chromium | 0.312 | 0.127
|
Nickel | 0.464 | 0.312
|
Fluoride | 50.2 | 22.3
|
Oil and grease | 8.44 | 8.44
|
TSS | 12.7 | 10.1
|
pH | (
1) | (
1)
|
(x) Ammonia rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with ammonia solution
|
Chromium | 0.006 | 0.002
|
Nickel | .008 | .006
|
Fluoride | .881 | .391
|
Oil and grease | .148 | .148
|
TSS | 222 | 178
|
pH | (
1) | (
1)
|
(y) Sawing or grinding spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt sawed or ground
|
Chromium | 0.015 | 0.006
|
Nickel | .002 | .015
|
Fluoride | 2.35 | 1.04
|
Oil and grease | .394 | .394
|
TSS | 591 | 473
|
pH | (
1) | (
1)
|
(z) Sawing or grinding rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of sawed or ground nickel-cobalt rinsed
|
Chromium | 0.067 | 0.027
|
Nickel | 0.100 | 0.067
|
Fluoride | 10.8 | 4.78
|
Oil and grease | 1.81 | 1.81
|
TSS | 2.72 | 217
|
pH | (
1) | (
1)
|
(aa) Steam cleaning condensate.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt steam cleaned
|
Chromium | 0.011 | 0.005
|
Nickel | 0.017 | 0.011
|
Fluoride | 1.79 | 0.795
|
Oil and grease | 0.301 | 0.301
|
TSS | 0.452 | 0.361
|
pH | (
1) | (
1)
|
(bb) Hydrostatic tube testing and ultrasonic testing wastewater—subpart C—NSPS. There shall be no discharge of process wastewater pollutants.
(cc) Degreasing spent solvents—subpart C—NSPS. There shall be no discharge of process wastewater pollutants.
(dd) Dye penetrant testing wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt tested with dye penetrant method
|
Chromium | 0.079 | 0.032
|
Nickel | 0.117 | 0.079
|
Fluoride | 12.7 | 5.63
|
Oil and grease | 2.13 | 2.13
|
TSS | 3.20 | 2.56
|
pH | (
1) | (
1)
|
(ee) Electrocoating rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt electrocoated
|
Chromium | 1.25 | 0.506
|
Nickel | 1.86 | 1.25
|
Fluoride | 201 | 89.0
|
Oil and grease | 33.7 | 33.7
|
TSS | 50.6 | 40.5
|
pH | (
1) | (
1)
|
(ff) Miscellaneous wastewater sources.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.091 | 0.037
|
Nickel | 0.136 | 0.091
|
Fluoride | 14.7 | 6.50
|
Oil and grease | 2.46 | 2.46
|
TSS | 3.69 | 2.95
|
pH | (
1) | (
1)
|
[50 FR 34270, Aug. 23, 1985; 51 FR 2885, Jan. 22, 1986, as amended at 54 FR 11349, Mar. 17, 1989; 54 FR 13606, Apr. 4, 1989]
§ 471.34 - Pretreatment standards for existing sources (PSES).
Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and by August 23, 1988 achieve the following pretreatment standards for existing sources (PSES). The mass of wastewater pollutants in nickel-cobalt forming wastewater introduced into a POTW shall not exceed the following values:
(a) Rolling spent neat oils—subpart C—PSES. There shall be no discharge of process wastewater pollutants.
(b) Rolling spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with emulsions
|
Chromium | 0.063 | 0.026
|
Nickel | 0.094 | 0.063
|
Fluoride | 10.1 | 4.49 |
(c) Rolling contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with water
|
Chromium | 0.028 | 0.011
|
Nickel | 0.042 | 0.028
|
Fluoride | 4.49 | 1.99 |
(d) Tube Reducing Spent Lubricant—subpart C—PSES. (1) There shall be no discharge of process wastewater pollutants except as provided under paragraph (d)(2) of this section.
(2) Process wastewater pollutants may be discharged, with no allowance for any pollutants discharged, provided the facility owner or operator demonstrates, on the basis of analytical methods set forth in or approved pursuant to 40 CFR part 136, that the concentrations of nitrosamine compounds in the wastewater discharged from the tube reducing process do not exceed 0.050 mg/l of N-nitrosodimethylamine, 0.020 mg/l of N-nitrosodiphenylamine, and 0.020 mg/l of N-nitrosodi-n-propylamine.
(3) The demonstration required under paragraph (d)(2) of this section shall be made once per month until the demonstration has been made for all three nitrosamine compounds for six consecutive months, after which time the demonstration may be made once per quarter. If a sample is found to contain any of the foregoing nitrosamine compounds at concentrations greater than those specified in paragraph (d)(2) of this section, the actions described in paragraph (d)(4) of this section shall be taken, and the demonstration required under paragraph (d)(2) of this section shall be made once per month until it has been made for all three nitrosamine compounds for six consecutive months.
(4) If sampling results show that any of the foregoing nitrosamine compounds is present in the process wastewater at concentrations greater than those specified in paragraph (d)(2) of this section, the facility owner or operator shall ensure that, within thirty days of receiving written notification of the sampling results, there is no further discharge of tube reducing spent lubricant wastewater until the owner or operator:
(i) Performs a subsequent analysis which demonstrates that the concentrations of the foregoing nitrosamine compounds do not exceed the levels specified in paragraph (d)(2) of this section; or
(ii) Substitutes a new tube reducing lubricant and thereafter complies with the requirements of paragraph (d)(3) of this section; or
(iii) Determines the source of the pollutant whose concentration exceeded the level specified in paragraph (d)(2) of this section and demonstrates to the satisfaction of the POTW control authority that such source has been eliminated.
(5) The concentration limits specified in paragraph (d)(2) of this section apply at the point of discharge from the tube reducing process. However, sampling after the tube reducing wastewater has been commingled with other wastewaters is permitted if:
(i) Any dilution caused by the other wastewaters is taken into account in determining the appropriate (i.e., lower) allowable discharge concentration; and
(ii) An analytical method of sufficient sensitivity is used to measure the levels of each of the foregoing nitrosamine compounds in the wastewaters being sampled.
(e) Drawing spent neat oils—subpart C—PSES. There shall be no discharge of process wastewater pollutants.
(f) Drawing spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt drawn with emulsions
|
Chromium | 0.036 | 0.014
|
Nickel | 0.053 | 0.036
|
Fluoride | 5.68 | 2.52 |
(g) Extrusion spent lubricants—subpart C—PSES. There shall be no discharge of process wastewater pollutants.
(h) Extrusion press or solution heat treatment contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of extruded nickel-cobalt heat treated
|
Chromium | 0.031 | 0.013
|
Nickel | 0.046 | 0.031
|
Fluoride | 4.95 | 2.20 |
(i) Extrusion press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt extruded
|
Chromium | 0.086 | 0.034
|
Nickel | 0.128 | 0.086
|
Fluoride | 13.8 | 6.13 |
(j) Forging equipment cleaning wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.002 | 0.0006
|
Nickel | 0.002 | 0.002
|
Fluoride | 0.238 | 0.106 |
(k) Forging contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of forged nickel-cobalt cooled with water
|
Chromium | 0.018 | 0.007
|
Nickel | 0.026 | 0.018
|
Fluoride | 2.82 | 1.25 |
(l) Forging press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.069 | 0.028
|
Nickel | 0.103 | 0.069
|
Fluoride | 11.2 | 4.94 |
(m) Forging spent lubricants—subpart C—PSES. There shall be no discharge of process wastewater pollutants.
(n) Stationary casting contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt cast with stationary methods
|
Chromium | 0.448 | 0.182
|
Nickel | 0.666 | 0.448
|
Fluoride | 72.0 | 32.0 |
(o) Vacuum melting steam condensate—subpart C—PSES. There shall be no allowance for the discharge of wastewater pollutants.
(p) Metal powder production atomization wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt metal powder atomized
|
Chromium | 0.970 | 0.393
|
Nickel | 1.44 | 0.970
|
Fluoride | 156 | 69.2 |
(q) Annealing and solution heat treatment contact cooling water—subpart C—PSES. There shall be no allowance for the discharge of wastewater pollutants.
(r) Wet air pollution control scrubber blowdown.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.300 | 0.122
|
Nickel | 0.446 | 0.300
|
Fluoride | 48.2 | 21.4 |
(s) Surface treatment spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 0.346 | 0.141
|
Nickel | 0.514 | 0.346
|
Fluoride | 55.7 | 24.7 |
(t) Surface treatment rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 0.873 | 0.354
|
Nickel | 1.30 | 0.873
|
Fluoride | 141 | 62.3 |
(u) Alkaline cleaning spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 0.013 | 0.005
|
Nickel | 0.019 | 0.013
|
Fluoride | 2.02 | 0.895 |
(v) Alkaline cleaning rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 0.086 | 0.035
|
Nickel | 0.128 | 0.086
|
Fluoride | 13.9 | 6.15 |
(w) Molten salt rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with molten salt
|
Chromium | 0.312 | 0.127
|
Nickel | 0.464 | 0.312
|
Fluoride | 50.2 | 22.3 |
(x) Ammonia rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with ammonia solution
|
Chromium | 0.006 | 0.002
|
Nickel | 0.008 | 0.006
|
Fluoride | 0.881 | 0.391 |
(y) Sawing or grinding spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt sawed or ground with emulsions
|
Chromium | 0.015 | 0.006
|
Nickel | 0.022 | 0.015
|
Fluoride | 2.35 | 1.04 |
(z) Sawing or grinding rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of sawed or ground nickel-cobalt rinsed
|
Chromium | 0.067 | 0.027
|
Nickel | 0.100 | 0.067
|
Fluoride | 10.8 | 4.78 |
(aa) Steam cleaning condensate.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt steam cleaned
|
Chromium | 0.011 | 0.005
|
Nickel | 0.017 | 0.011
|
Fluoride | 1.79 | 0.795 |
(bb) Hydrostatic Tube Testing and Ultrasonic Testing Wastewater—subpart C—PSES. There shall be no allowance for the discharge of process wastewater pollutants.
(cc) Degreasing Spent Solvents—subpart C—PSES. There shall be no discharge of process wastewater pollutants.
(dd) Dye Penetrant Testing Wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt tested with dye penetrant method
|
Chromium | 0.079 | 0.032
|
Nickel | 0.117 | 0.079
|
Fluoride | 12.7 | 5.63 |
(ee) Electrocoating rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt electrocoated
|
Chromium | 1.25 | 0.506
|
Nickel | 1.86 | 1.25
|
Fluoride | 201 | 89.0 |
(ff) Miscellaneous wastewater sources.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.091 | 0.037
|
Nickel | 0.136 | 0.091
|
Fluoride | 14.7 | 6.50 |
[50 FR 34270, Aug. 23, 1985; 51 FR 2885, Jan. 22, 1986, as amended at 54 FR 11349, Mar. 17, 1989; 54 FR 13606, Apr. 4, 1989]
§ 471.35 - Pretreatment standards for new sources (PSNS).
Except as provided in 40 CFR 403.7, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources. The mass of wastewater pollutants in nickel-cobalt forming process wastewater introduced into a POTW shall not exceed the following values:
(a) Rolling spent neat oils—subpart C—PSNS. There shall be no discharge of process wastewater pollutants.
(b) Rolling spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with emulsions
|
Chromium | 0.063 | 0.026
|
Nickel | 0.094 | 0.063
|
Fluoride | 10.1 | 4.49 |
(c) Rolling contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt rolled with water
|
Chromium | 0.028 | 0.012
|
Nickel | 0.042 | 0.028
|
Fluoride | 4.49 | 1.99 |
(d) Tube Reducing Spent Lubricant—subpart C—PSNS. (1) There shall be no discharge of process wastewater pollutants except as provided under paragraph (d)(2) of this section
(2) Process wastewater pollutants may be discharged, with no allowance for any pollutants discharged, provided the facility owner or operator demonstrates, on the basis of analytical methods set forth in or approved pursuant to 40 CFR part 136, that the concentrations of nitrosamine compounds in the wastewater discharged from the tube reducing process do not exceed 0.050 mg/l of N-nitrosodimethylamine, 0.020 mg/l of N-nitrosodiphenylamine, and 0.020 mg/l of N-nitrosodi-n-propylamine.
(3) The demonstration required under subparagraph (d)(2) of this section shall be made once per month until the demonstration has been made for all three nitrosamine compounds for six consecutive months, after which time the demonstration may be made once per quarter. If a sample is found to contain any of the foregoing nitrosamine compounds at concentrations greater than those specified in paragraph (d)(2) of this section, the actions described in paragraph (d)(4) of this section shall be taken, and the demonstration required under paragraph (d)(2) of this section shall be made once per month until it has been made for all three nitrosamine compounds for six consecutive months.
(4) If sampling results show that any of the foregoing nitrosamine compounds is present in the process wastewater at concentrations greater than those specified in subparagraph (d)(2) of this section, the facility owner or operator shall ensure that, within thirty days of receiving written notification of the sampling results, there is no further discharge of tube reducing spent lubricant wastewater until the owner or operator:
(i) Performs a subsequent analysis which demonstrates that the concentrations of the foregoing nitrosamine compounds do not exceed the levels specified in paragraph (d)(2) of this section (2); or
(ii) Substitutes a new tube reducing lubricant and thereafter complies with the requirements of paragraph (d)(3) of this section; or
(iii) Determines the source of the pollutant whose concentration exceeded the level specified in subparagraph (2) above and demonstrates to the satisfaction of the POTW control authority that such source has been eliminated.
(5) The concentration limits specified in paragraph (d)(2) of this section apply at the point of discharge from the tube reducing process. However, sampling after the tube reducing wastewater has been commingled with other wastewaters is permitted if:
(i) Any dilution caused by the other wastewaters is taken into account in determining the appropriate (i.e., lower) allowable discharge concentration; and
(ii) An analytical method of sufficient sensitivity is used to measure the levels of each of the foregoing nitrosamine compounds in the wastewaters being sampled.
(e) Drawing spent neat oils—subpart C—PSNS. There shall be no discharge of process wastewater pollutants.
(f) Drawing spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt drawn with emulsions
|
Chromium | 0.036 | 0.015
|
Nickel | 0.053 | 0.036
|
Fluoride | 5.68 | 2.52 |
(g) Extrusion spent lubricants—subpart C—PSNS. There shall be no discharge of process wastewater pollutants.
(h) Extrusion press or solution heat treatment contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of extruded nickel-cobalt heat treated
|
Chromium | 0.031 | 0.013
|
Nickel | 0.046 | 0.031
|
Fluoride | 4.95 | 2.20 |
(i) Extrusion press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt extruded
|
Chromium | 0.086 | 0.034
|
Nickel | 0.128 | 0.086
|
Fluoride | 13.8 | 6.13 |
(j) Forging equipment cleaning wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.002 | 0.0006
|
Nickel | 0.002 | 0.002
|
Fluoride | 0.238 | 0.106 |
(k) Forging contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of forged nickel-cobalt cooled with water
|
Chromium | 0.018 | 0.007
|
Nickel | 0.026 | 0.018
|
Fluoride | 2.82 | 1.25 |
(l) Forging press hydraulic fluid leakage.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt forged
|
Chromium | 0.069 | 0.028
|
Nickel | 0.103 | 0.069
|
Fluoride | 11.2 | 4.94 |
(m) Forging spent lubricants—subpart C—PSNS. There shall be no discharge of process wastewater pollutants.
(n) Stationary casting contact cooling water.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt cast with stationary methods
|
Chromium | 0.448 | 0.182
|
Nickel | 0.666 | 0.448
|
Fluoride | 72.0 | 32.0 |
(o) Vacuum melting steam condensate—subpart C—PSNS. There shall be no allowance for the discharge of process wastewater pollutants.
(p) Metal powder production atomization wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt metal powder atomized
|
Chromium | 0.970 | 0.393
|
Nickel | 1.44 | 0.970
|
Fluoride | 156 | 69.2 |
(q) Annealing and Solution Heat Treatment Contact Cooling Water—subpart C—PSNS. There shall be no allowance for the discharge of process wastewater pollutant.
(r) Wet Air Pollution Control Scrubber Blowdown.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.300 | 0.122
|
Nickel | 0.450 | 0.300
|
Fluoride | 48.2 | 21.4 |
(s) Surface treatment spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 0.346 | 0.141
|
Nickel | 0.515 | 0.346
|
Fluoride | 55.7 | 24.7 |
(t) Surface treatment rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt surface treated
|
Chromium | 0.874 | 0.354
|
Nickel | 1.30 | 0.873
|
Fluoride | 141 | 62.3 |
(u) Alkaline cleaning spent baths.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 0.013 | 0.005
|
Nickel | 0.019 | 0.013
|
Fluoride | 2.02 | 0.895 |
(v) Alkaline cleaning rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt alkaline cleaned
|
Chromium | 0.086 | 0.035
|
Nickel | 0.128 | 0.086
|
Fluoride | 13.9 | 6.15 |
(w) Molten salt rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with molten salt
|
Chromium | 0.312 | 0.127
|
Nickel | 0.464 | 0.312
|
Fluoride | 50.2 | 22.3 |
(x) Ammonia rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt treated with ammonia solution
|
Chromium | 0.006 | 0.002
|
Nickel | 0.008 | 0.006
|
Fluoride | 0.881 | 0.391 |
(y) Sawing or grinding spent emulsions.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt sawed or ground with emulsions
|
Chromium | 0.015 | 0.006
|
Nickel | 0.022 | 0.015
|
Fluoride | 2.35 | 1.04 |
(z) Sawing or grinding rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of sawed or ground nickel-cobalt rinsed
|
Chromium | 0.067 | 0.027
|
Nickel | 0.100 | 0.067
|
Fluoride | 10.8 | 4.78 |
(aa) Steam cleaning condensate.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt steam cleaned
|
Chromium | 0.011 | 0.005
|
Nickel | 0.017 | 0.011
|
Fluoride | 1.79 | 0.795 |
(bb) Hydrostatic tube testing and ultrasonic testing wastewater—subpart C—PSNS. There shall be no allowance discharge of process wastewater pollutants.
(cc) Degreasing spent solvents—subpart C—PSNS. There shall be no discharge of process wastewater pollutants.
(dd) Dye penetrant testing wastewater.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt tested with dye penetrant method
|
Chromium | 0.079 | 0.032
|
Nickel | 0.117 | 0.079
|
Fluoride | 12.7 | 5.63 |
(ee) Electrocoating rinse.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt electrocoated
|
Chromium | 1.25 | 0.506
|
Nickel | 1.86 | 0.125
|
Fluoride | 201 | 89.0 |
(ff) Miscellaneous wastewater sources.
Pollutant or pollutant property
| Maximum for any 1 day
| Maximum for monthly average
|
---|
| mg/off-kg (pounds per million off-pounds) of nickel-cobalt formed
|
Chromium | 0.091 | 0.037
|
Nickel | 0.136 | 0.091
|
Fluoride | 14.7 | 6.50 |
[50 FR 34270, Aug. 23, 1985; 51 FR 2886, Jan. 22, 1986, as amended at 54 FR 11350, Mar. 17, 1989]
§ 471.36 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional pollutant control technology (BCT). [Reserved]
authority: Secs. 301, 304(b), (c), (e), and (g), 306(b) and (c), 307, 308, and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972 as amended by the Clean Water Act of 1977) (the “Act”);
33 U.S.C. 1311,
1314,
c,
e,
and, 1316(b) and
c,
and; 86 Stat. 816, Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217
source: 50 FR 34270, Aug. 23, 1985, unless otherwise noted.
cite as: 40 CFR 471.34