Beginning on the compliance date of any energy conservation standards for air cleaners, any representations made with respect to the energy use or efficiency of these products, including those made for certification purposes, must be made in accordance with the results of testing pursuant to this appendix. Manufacturers may choose to test in accordance with this appendix to certify compliance with any energy conservation standards prior to the applicable compliance date for those standards.

0. Incorporation by Reference

DOE incorporated by reference in § 430.3 the entire standard for AHAM AC-1-2020, AHAM AC-7-2022, ASTM E741-11(2017), and IEC 62301. However, only enumerated provisions of AHAM AC-1-2020, AHAM AC-7-2022, and IEC 62301 apply to this appendix, as follows:

0.1 AHAM AC-1-2020

(a) Sections 4.2 through 4.6;

(b) Sections 5 through 7;

(c) Section 8.1;

(d) Annex A;

(e) Annex I; and

(f) AHAM Standard Interpretation.

0.2 AHAM AC-7-2022

(a) Sections 2.2 and 2.3, sections 2.4.1 through 2.4.2.4, and sections 2.6 through 2.9;

(b) Sections 3.1 through 3.6.3;

(c) Section 4;

(d) Sections 5.3 through 5.7.4; and

(e) Sections 6 and 7.

0.3 IEC 62301: Household Electrical Appliances—Measurement of Standby Power

(a) Sections 4.4.1 through 4.4.3; and

(b) Section 5.3.

1. Scope of Coverage

This appendix contains the test requirements to measure the energy performance of a conventional room air cleaner, as defined at § 430.2, with smoke CADR and dust CADR between 10 to 600 cubic feet per minute (cfm), inclusive.

2. Definitions

The definitions in sections 2.2, 2.3, 2.4.1 through 2.4.2.4, 2.6 through 2.8, and 2.9 of AHAM AC-7-2022 apply to this test procedure, including the applicable provisions of Annex I of AHAM AC-1-2020 as referenced in section 2.9 of AHAM AC-7-2022.

3. Test Conditions

Testing conditions shall be as specified in sections 3.1 through 3.6.3 of AHAM AC-7-2022, including the applicable provisions of sections 4.2 through 4.6 and Annex A of AHAM AC-1-2020 as referenced in sections 3.2.1, 3.3, 3.4, 3.5, and 3.6.2 of AHAM AC-7-2022 and the applicable provisions of ASTM E 741-11(2017) as referenced in section 3.3 of AHAM AC-7-2022. Additionally, the following requirements are also applicable:

3.1. Placement for Testing. The air cleaner test unit shall be placed in the test chamber as specified in section 3.6.2 of AHAM AC-7-2022. Additionally, the placement instructions specified in AHAM Standard Interpretation in AHAM AC-1-2020 are also applicable.

3.2. Air Cleaners with Network Mode Capability. The air cleaner software update requirements specified in section 3.6.3.8 of AHAM AC-7-2022 are applicable. Additionally, software updates shall be conducted, if available, prior to initiating any testing. Software updates shall not be bypassed, even if the unit will operate without updates.

4. Instrumentation

Test instruments shall be as specified in section 4 of AHAM AC-7-2022, including the applicable provisions of sections 4.4.1 through 4.4.3 of IEC 62301.

5. Active Mode CADR and Power Measurement

Measurement of smoke CADR, dust CADR, and pollen CADR shall be as specified in sections 5 through 7 of AHAM AC-1-2020, respectively. Measurement of active mode power shall be as specified in sections 5.3 through 5.7.4 of AHAM AC-7-2022, including the applicable provisions of sections 5.2.5 and 6.2.5 of AHAM AC-1-2020 as referenced in section 5.7.1 of AHAM AC-7-2022. Additionally, the following requirement is also applicable:

5.1. Calculation of PM2.5 CADR.

5.1.1 PM2.5 CADR should be calculated as specified in section 2.9 of AHAM AC-7-2022.

5.1.2. For determining compliance only with the standards specified in § 430.32(ee)(1), PM2.5 CADR may alternately be calculated using the smoke CADR and dust CADR values determined according to Sections 5 and 6, respectively, of AHAM AC-1-2020, according to the following equation:

6. Standby Mode Power Measurement

Standby mode power consumption shall be measured as specified in section 6 of AHAM AC-7-2022, including the applicable provisions of section 5.3 of IEC 62301.

7. Total Energy Calculation

Annual energy consumption, expressed in kilowatt-hours per year, and integrated energy factor, expressed in CADR per watt, shall be calculated as specified in section 7 of AHAM AC-7-2022.

[88 FR 14044, Mar. 6, 2023, as amended at 88 FR 53371, Aug. 8, 2023; 88 FR 21814, Apr. 11, 2023]