Note:
After September 19, 2022, representations made with respect to the water consumption of water closets or urinals must fairly disclose the results of testing pursuant to this appendix.
On or after April 22, 2022 and prior to September 19, 2022 representations, including compliance certifications, made with respect to the water consumption of water closets or urinals must fairly disclose the results of testing pursuant to either this appendix or the appendix as it appeared at 10 CFR part 430, subpart B, in the 10 CFR parts 200 to 499 edition revised as of January 1, 2014. Representations made with respect to the water consumption of water closets or urinals tested within that range of time must fairly disclose the results of testing under the selected version. Given that after September 19, 2022 representations with respect to the water consumption of water closets and urinals must be made in accordance with tests conducted pursuant to this appendix, manufacturers may wish to begin using this test procedure as soon as possible.
0. Incorporation by Reference
DOE incorporated by reference in § 430.3, the entire standard for ASME A112.19.2-2018; however, only enumerated provisions of that document apply to this appendix, as follows. Treat precatory language in ASME A112.19.2-2018 as mandatory for the purpose of testing.
a. Section 7.1.1 “All tests,” including Figures 11 and 12, as specified in section 2.a of this appendix;
b. Section 7.1.2 “Gravity flush tank water closets,” as specified in section 2.a of this appendix;
c. Section 7.1.3 “Flushometer tank, electro-hydraulic, or other pressurized flushing device water closets,” as specified in section 2.a of this appendix;
d. Section 7.1.4 “Flushometer valve water closets,” as specified in section 2.a of this appendix;
e. Section 7.1.5 “Procedures for standardizing the water supply system,” including Figures 11 and 12, as specified in section 2.a of this appendix;
f. Section 7.3 “Water consumption test,” as specified in section 3.a of this appendix, except sections 7.3.4 and 7.3.5;
f. Section 8.2.1, including Figure 12, as specified in section 2.b of this appendix;
g. Section 8.2.2, as specified in section 2.b of this appendix;
h. Section 8.2.3, as specified in section 2.b of this appendix;
i. Section 8.6 “Water Consumption Test,” as specified in section 3.b of this appendix, except sections 8.6.3 and 8.6.4;
j. Table 5 “Static test pressures for water closets, kPa (psi),” as specified in sections 2.a and 3.a of this appendix; and
k. Table 6 “Static test pressures for urinals, kPa (psi)” as specified in sections 2.a and 3.a of this appendix.
In cases where there is a conflict, the language of the test procedure in this appendix takes precedence over ASME A112.19.2-2018.
1. Scope
This appendix sets forth the test requirements used to measure the hydraulic performances of water closets and urinals.
2. Test Apparatus and General Instructions
a. When testing a water closet, use the test apparatus and follow the instructions specified in Sections 7.1.1 (including Table 5), 7.1.2, 7.1.3, 7.1.4, and 7.1.5 of ASME A112.19.2-2018). The flushometer valve used in the water consumption test must represent the maximum design flush volume of the water closet. Record each measurement at the resolution of the test apparatus. Round each calculation of water consumption for each tested unit to the same number of significant digits as the previous step.
b. When testing a urinal, use the test apparatus and follow the instructions specified in Sections 8.2.1, 8.2.2, and 8.2.3 (including Table 6) of ASME A112.19.2-2018. The flushometer valve used in the water consumption test must represent the maximum design flush volume of the urinal. Record each measurement at the resolution of the test apparatus. Round each calculation of water consumption for each tested unit to the same number of significant digits as the previous step.
3. Test Measurement
a. Water closets:
(i) Measure the water flush volume for water closets, expressed in gallons per flush (gpf) or liters per flush (Lpf), in accordance with Section 7.3, Water Consumption Test, of ASME A112.19.2-2018. For dual-flush water closets, the measurement of the water flush volume shall be conducted separately for the full-flush and reduced-flush modes and in accordance with the test requirements specified Section 7.3, Water Consumption Test, of ASME A112.19.2-2018. The final measured flush volume for each tested unit is the average of the total flush volumes recorded at each test pressure as specified in Table 5 “Static test pressures for water closets, kPa (psi),” of ASME A112.19.2-2018, based on the average of the individual flush volumes at a given pressure from the three tests.
(ii) Flush volume and tank trim component adjustments: For gravity flush tank water closets, set trim components that can be adjusted to cause an increase in flush volume, including (but not limited to) the flapper valve, fill valve, and tank water level, in accordance with the printed installation instructions supplied by the manufacturer with the unit. If the printed installation instructions for the model to be tested do not specify trim setting adjustments, adjust these trim components to the maximum water use setting so that the maximum flush volume is produced without causing the water closet to malfunction or leak. Set the water level in the tank to the maximum water line designated in the printed installation instructions supplied by the manufacturer or the designated water line on the tank itself, whichever is higher. If the printed installation instructions or the water closet tank do not indicate a water level, adjust the water level to 1±0.1 inches below the top of the overflow tube or, for gravity flush tank water closets that do not contain an overflow tube, 1±0.1 inches below the top rim of the water-containing vessel for each designated pressure specified in Table 5 of ASME A112.19.2-2018.
b. Urinals—Measure water flush volume for urinals, expressed in gallons per flush (gpf) or liters per flush (Lpf), in accordance with Section 8.6, Water Consumption Test, of ASME A112.19.2-2018. The final measured flush volume for each tested unit is the average of the total flush volumes recorded at each test pressure as specified in Table 6 “Static test pressures for urinals, kPa (psi),” of ASME A112.19.2-2018, based on the average of the individual flush volumes at a given pressure from the three tests.
[87 FR 16386, Mar. 23, 2022]