Appendix - Table 4 to Subpart BB of Part 63—Operating Parameters, Operating Limits and Data Monitoring, Recordkeeping and Compliance Frequencies
View all text of [None - None]
Appendix - Table 4 to Subpart BB of Part 63—Operating Parameters, Operating Limits and Data Monitoring, Recordkeeping and Compliance Frequencies
For the operating parameter applicable to you, as specified in Table 3 . . .
You must establish the following operating limit during your performance test . . .
And you must monitor, record, and demonstrate continuous compliance using these minimum frequencies . . .
Data measurement
Data recording
Data averaging
period for
compliance
Absorbers (Wet Scrubbers)
Influent liquid flow
Minimum inlet liquid flow
Continuous
Every 15 minutes
Daily.
Influent liquid flow rate and gas stream flow rate
Minimum influent liquid-to-gas ratio
a
Continuous
Every 15 minutes
Daily.
For the operating parameter applicable to you, as specified in Table 3
You must establish the following operating limit
And you must monitor, record, and demonstrate continuous compliance using these minimum frequencies . . .
Data measurement
Data recording
Data averaging
period for
compliance.
Pressure drop
Pressure drop range
Continuous
Every 15 minutes
Daily.
Sorbent Injection
Sorbent injection rate
Minimum injection rate
Continuous
Every 15 minutes
Daily.
Sorbent injection carrier gas flow rate
Minimum carrier gas flow rate
Continuous
Every 15 minutes
Daily.
Fabric Filters
Alarm time
Maximum alarm time is not established on a site-specific basis but is specified in
§ 63.605
(f)(9)
Continuous
Each date and time of alarm start and stop
Maximum alarm time specified in
§ 63.605
(f)(9).
Wet Electrostatic Precipitator
Secondary voltage
Secondary voltage range
Continuous
Every 15 minutes
Daily.
[82 FR 45201, Sept. 28, 2017]