Appendix - Table 8 to Subpart JJJ of Part 63—Operating Parameters for Which Levels Are Required To Be Established for Continuous and Batch Process Vents and Aggregate Batch Vent Streams
Device Parameters to be monitored Established operating parameter(s)
Thermal incineratorFirebox temperatureMinimum temperature.
Catalytic incineratorTemperature upstream and downstream of the catalyst bedMinimum upstream temperature; and minimum temperature difference across the catalyst bed.
Boiler or process heaterFirebox temperatureMinimum temperature.
Scrubber for halogenated ventspH of scrubber effluent; and scrubber liquid and gas flow rates [§ 63.1324(b)(4)(ii)]Minimum pH; and minimum liquid/gas ratio.
AbsorberExit temperature of the absorbing liquid; and exit specific gravity of the absorbing liquidMaximum temperature; and maximum specific gravity.
CondenserExit temperatureMaximum temperature.
Carbon adsorberTotal regeneration steam flow or nitrogen flow, or pressure (gauge or absolute) a during carbon bed regeneration cycle; and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s))Maximum flow or pressure; and maximum temperature.
Other devices (or as an alternate to the requirements previously presented in this table) bHAP concentration level or reading at outlet of deviceMaximum HAP concentration or reading.

a 25 to 50 mm (absolute) is a common pressure level obtained by pressure swing absorbers.

b Concentration is measured instead of an operating parameter.

[65 FR 38145, June 19, 2000]
authority: 42 U.S.C. 7401
source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.