Appendix - Table 6 to Subpart OOO of Part 63—Coefficients for Total Resource Effectiveness a
Control device basis Values of coefficients
A B C
Flare5.276 × 10−19.98 × 10−22.096 × 10−3
Thermal Incinerator 0 Percent Recovery4.068 × 10−11.71 × 10−28.664 × 10−3
Thermal Incinerator 70 Percent Recovery6.868 × 10−13.21 × 10−33.546 × 10−3

a Use according to procedures outlined in this section.

MJ/scm = MegaJoules per standard cubic meter.

scm/min = Standard cubic meters per minute.

authority: 42 U.S.C. 7401