Regulations last checked for updates: Nov 22, 2024

Title 40 - Protection of Environment last revised: Nov 20, 2024
Appendix - Table 2 to Subpart UUU of Part 63—Operating Limits for Metal HAP Emissions From Catalytic Cracking Units

As stated in § 63.1564(a)(2), you shall meet each operating limit in the following table that applies to you.

For each new or existing catalytic cracking unit . . . For this type of continuous
monitoring system . . .
For this type of control
device . . .
You shall meet this operating
limit . . .
1. Subject to the NSPS for PM in 40 CFR 60.102 and not elect § 60.100(e)Continuous opacity monitoring systemAnyOn and after August 1, 2017, maintain the 3-hour rolling average opacity of emissions from your catalyst regenerator vent no higher than 20 percent.
2. Subject to NSPS for PM in 40 CFR 60.102a(b)(1)(i) or electing § 60.100(e)a. PM CEMSAnyNot applicable.
b. Continuous opacity monitoring system used to comply with a site-specific opacity limitCyclone or electrostatic precipitatorMaintain the 3-hour rolling average opacity of emissions from your catalyst regenerator vent no higher than the site-specific opacity limit established during the performance test.
c. Continuous parameter monitoring systemsElectrostatic precipitatori. Maintain the daily average coke burn-off rate or daily average flow rate no higher than the limit established in the performance test.
ii. Maintain the 3-hour rolling average total power and secondary current above the limit established in the performance test.
d. Continuous parameter monitoring systemsWet scrubberi. Maintain the 3-hour rolling average liquid-to-gas ratio above the limit established in the performance test.
ii. Except for periods of startup, shutdown, and hot standby, maintain the 3-hour rolling average pressure drop above the limit established in the performance test. 1
e. Bag leak detection (BLD) systemFabric filterMaintain particulate loading below the BLD alarm set point established in the initial adjustment of the BLD system or allowable seasonal adjustments.
3. Subject to NSPS for PM in 40 CFR 60.102a(b)(1)(ii)AnyAnyThe applicable operating limits in Item 2 of this table.
4. Option 1a: Elect NSPS subpart J requirements for PM per coke burn limit, not subject to the NSPS for PM in 40 CFR 60.102 or 60.102a(b)(1)AnyAnySee Item 1 of this table.
5. Option 1b: Elect NSPS subpart Ja requirements for PM per coke burn-off limit, not subject to the NSPS for PM in 40 CFR 60.102 or 60.102a(b)(1)AnyAnyThe applicable operating limits in Item 2.b, 2.c, 2.d, and 2.e of this table.
6. Option 1c: Elect NSPS subpart Ja requirements for PM concentration limit, not subject to the NSPS for PM in 40 CFR 60.102 or 60.102a(b)(1)PM CEMSAnyNot applicable.
7. Option 2: PM per coke burn-off limit not subject to the NSPS for PM in 40 CFR 60.102 or 60.102a(b)(1)a. Continuous opacity monitoring system used to comply with a site-specific opacity limitCyclone, fabric filter, or electrostatic precipitatorSee Item 2.b of this table. Alternatively, before August 1, 2017, you may maintain the hourly average opacity of emissions from your catalyst generator vent no higher than the site-specific opacity limit established during the performance test.
b. Continuous parameter monitoring systemsi. Electrostatic precipitator(1) See Item 2.c.i of this table.
(2) See item 2.c.ii of this table. Alternatively, before August 1, 2017, you may maintain the daily average voltage and secondary current above the limit established in the performance test.
ii. Wet scrubber(1) See Item 2.d.i of this table. Alternatively, before August 1, 2017, you may maintain the daily average liquid-to-gas ratio above the limit established in the performance test.
(2) See Item 2.d.ii of the table. Alternatively, before August 1, 2017, you may maintain the daily average pressure drop above the limit established in the performance test (not applicable to a wet scrubber of the non-venturi jet-ejector design).
c. Bag leak detection (BLD) systemFabric filterSee item 2.e of this table.
8. Option 3: Ni lb/hr limit not subject to the NSPS for PM in 40 CFR 60.102a. Continuous opacity monitoring systemCyclone, fabric filter, or electrostatic precipitatorMaintain the 3-hour rolling average Ni operating value no higher than the limit established during the performance test. Alternatively, before August 1, 2017, you may maintain the daily average Ni operating value no higher than the limit established during the performance test.
b. Continuous parameter monitoring systemsi. Electrostatic precipitator(1) See Item 2.c.i of this table.
(2) Maintain the monthly rolling average of the equilibrium catalyst Ni concentration no higher than the limit established during the performance test.
(3) See Item 2.c.ii of this table. Alternatively, before August 1, 2017, you may maintain the daily average voltage and secondary current (or total power input) above the established during the performance test.
ii. Wet scrubber(1) Maintain the monthly rolling average of the equilibrium catalyst Ni concentration no higher than the limit established during the performance test.
(2) See Item 2.d.i of this table. Alternatively, before August 1, 2017, you may maintain the daily average liquid-to-gas ratio above the limit established during the performance test.
(3) See Item 2.d.ii of this table. Alternatively, before August 1, 2017, you may maintain the daily average pressure drop above the limit established during the performance test (not applicable to a non-venturi wet scrubber of the jet-ejector design).
c. Bag leak detection (BLD) systemFabric filterSee item 2.e of this table.
9. Option 4: Ni per coke burn-off limit not subject to the NSPS for PM in 40 CFR 60.102a. Continuous opacity monitoring systemCyclone, fabric filter, or electrostatic precipitatorMaintain the 3-hour rolling average Ni operating value no higher than Ni operating limit established during the performance test. Alternatively, before August 1, 2017, you may elect to maintain the daily average Ni operating value no higher than the Ni operating limit established during the performance test.
b. Continuous parameter monitoring systemsi. Electrostatic precipitator(1) Maintain the monthly rolling average of the equilibrium catalyst Ni concentration no higher than the limit established during the performance test.
(2) See Item 2.c.ii of this table. Alternatively, before August 1, 2017, you may maintain the daily average voltage and secondary current (or total power input) above the limit established during the performance test.
ii. Wet scrubber(1) Maintain the monthly rolling average of the equilibrium catalyst Ni concentration no higher than the limit established during the performance test.
(2) See Item 2.d.i of this table. Alternatively, before August 1, 2017, you may maintain the daily average liquid-to-gas ratio above the limit established during the performance test.
(3) See Item 2.d.ii of this table. Alternatively, before August 1, 2017, you may maintain the daily average pressure drop above the limit established during the performance test (not applicable to a non-venturi wet scrubber of the jet-ejector design).
c. Bag leak detection (BLD) systemFabric filterSee item 2.e of this table.
10. During periods of startup, shutdown, or hot standbyAnyAnyMeet the requirements in § 63.1564(a)(5).

1 If you use a jet ejector type wet scrubber or other type of wet scrubber equipped with atomizing spray nozzles, you can use the alternative in § 63.1573(b), and comply with the daily inspections, recordkeeping, and repair provisions, instead of a continuous parameter monitoring system for pressure drop across the scrubber.

[80 FR 75280, Dec. 1, 2015, as amended at 81 FR 45244, July 13, 2016]
authority: 42 U.S.C. 7401
source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.