Regulations last checked for updates: Nov 22, 2024

Title 40 - Protection of Environment last revised: Nov 20, 2024
Appendix - Table 12 to Subpart WWWW of Part 63—Data Requirements for New and Existing Continuous Lamination Lines and Continuous Casting Lines Complying With a Lbs/Ton Organic HAP Emissions Limit on a Per Line Basis

As required in § 63.5865(b), in order to comply with a lbs/ton organic HAP emissions limit for continuous lamination lines and continuous casting lines you must determine the data in the following table:

For each line where the wet- out area . . . And the oven . . . You must determine . . .
1. Is uncontrolleda. Is uncontrolledi. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual uncontrolled oven organic HAP emissions, and
iii. Annual neat resin plus and neat gel coat plus applied.
2. Has an enclosure that is not a PTE and the captured organic HAP emissions are controlled by an add-on control devicea. Is uncontrolledi. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual controlled wet-out area organic HAP emissions,
iii. Annual uncontrolled oven organic HAP emissions,
iv. The capture efficiency of the wet-out area enclosure,
v. The destruction efficiency of the add-on control device, and
vi. The amount of neat resin plus and neat gel coat plus applied.
3. Has an enclosure that is a PTE, and the captured organic HAP emissions are controlled by an add-on control devicea. Is uncontrolledi. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual controlled wet-out area organic HAP emissions,
iii. Annual uncontrolled oven organic HAP emissions,
iv. That the wet-out area enclosure meets the requirements of EPA Method 204 of appendix M to 40 CFR part 51 for a PTE,
v. The destruction efficiency of the add-on control device, and
vi. The amount of neat resin plus and neat gel coat plus applied.
4. Is uncontrolleda. Is controlled by an add-on control devicei. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual uncontrolled oven organic HAP emissions,
iii. Annual controlled oven organic HAP emissions,
iv. The capture efficiency of the oven,
v. The destruction efficiency of the add-on control device, and
vi. The amount of neat resin plus and neat gel coat plus applied.
5. Has an enclosure that is not a PTE and the captured organic HAP emissions are controlled by an add-on control devicea. Is controlled by an add-on control devicei. Annual uncontrolled wet-out area organic HAP emissions,
ii. Annual controlled wet-out area organic HAP emissions,
iii. Annual uncontrolled oven organic HAP emissions,
iv. Annual controlled oven organic HAP emissions,
v. The capture efficiency of the wet-out area enclosure,
vi. The capture efficiency of the oven,
vii. The destruction efficiency of the add-on control device, and
viii. The amount of neat resin plus and neat gel coat plus applied.
6. Has an enclosure that is a PTE, and the captured organic HAP emissions are controlled by add-on control devicea. Is controlled by an add-on control devicei. That the wet-out area enclosure meets the requirements of EPA Method 204 of appendix M to 40 CFR part 51 for a PTE,
ii. The capture efficiency of the oven,
iii. Inlet organic HAP emissions to the an add-on control device, and
iv. Outlet organic HAP emissions from the add-on control device.
authority: 42 U.S.C. 7401
source: 57 FR 61992, Dec. 29, 1992, unless otherwise noted.