Citation
| Subject
| Applies to subpart
QQQQQ?
| Explanation
|
---|
§ 63.1 | Applicability | Yes
| |
§ 63.2 | Definitions | Yes
| |
§ 63.3 | Units and Abbreviations | Yes
| |
§ 63.4 | Prohibited Activities | Yes
| |
§ 63.5 | Construction/Reconstruction | Yes
| |
§ 63.6(a)-(c), (i)-(j) | Compliance with Standards and Maintenance Requirements | Yes
| |
§ 63.6(d) | [Reserved]
| | |
§ 63.6(e)(1)(i)-(ii) | SSM Operation and Maintenance Requirements | No, for new or reconstructed sources which commenced construction or reconstruction after May 3, 2018. Yes, for all other affected sources before August 7, 2019, and No thereafter | Subpart QQQQQ requires affected units to meet emissions standards at all times. See § 63.9505 for general duty requirement.
|
§ 63.6(e)(1)(iii), (e)(2) | Operation and Maintenance | Yes
| |
§ 63.6(e)(3) | SSM Plan Requirements | No, for new or reconstructed sources which commenced construction or reconstruction after May 3, 2018. Yes, for all other affected sources before August 7, 2019, and No thereafter | Subpart QQQQQ requires affected units to meet emissions standards at all times.
|
§ 63.6(f)(1) | SSM Exemption | No, for new or reconstructed sources which commenced construction or reconstruction after May 3, 2018. Yes, for all other affected sources before August 7, 2019, and No thereafter | Subpart QQQQQ requires affected units to meet emissions standards at all times.
|
§ 63.6(f)(2)-(3) | Compliance with Nonopacity Emission Standards | Yes
| |
§ 63.6(g) | Use of an Alternative Nonopacity Emission Standard | No | Subpart QQQQQ contains no work practice standards.
|
§ 63.6(h) | Compliance with Opacity and Visible Emission Standards | No | Subpart QQQQQ contains no opacity or VE limits.
|
§ 63.7(a)(1)-(2) | Applicability and Performance Test Dates | No | Subpart QQQQQ includes dates for initial compliance demonstrations.
|
§ 63.7(a)(3), (b)-(h) | Performance Testing Requirements | No | Subpart QQQQQ does not require performance tests.
|
§ 63.8(a)(1)-(2) | Applicability and Relevant Standards for CMS | Yes
| |
§ 63.8(a)(3) | [Reserved]
| | |
§ 63.8(a)(4) | Additional Monitoring Requirements for Control Devices in § 63.11 | No | Subpart QQQQQ does not require flares.
|
§ 63.8(b) | Conduct of Monitoring | Yes
| |
§ 63.8(c)(1)(i), (iii) | Continuous Monitoring System (CMS) SSM Requirements | No, for new or reconstructed sources which commenced construction or reconstruction after May 3, 2018. Yes, for all other affected sources before August 7, 2019, and No thereafter.
| |
§ 63.8(c)(1)(ii), (c)(2), (c)(3) | CMS Repairs, Operating Parameters, and Performance Tests | Yes
| |
§ 63.8(c)(4) | Continuous Monitoring System (CMS) Requirements | No | Subpart QQQQQ does not require CMS.
|
§ 63.8(c)(5) | Continuous Opacity Monitoring System (COMS) Minimum Procedures | No | Subpart QQQQQ does not require COMS.
|
§ 63.8(c)(6) | Zero and High Level Calibration Check Requirements | No | Subpart QQQQQ specifies calibration requirements.
|
§ 63.8(c)(7)-(8) | Out-of-Control Periods | No | Subpart QQQQQ specifies out-of-control periods and reporting requirements.
|
§ 63.8(d) | CMS Quality Control | No | Subpart QQQQQ requires a monitoring plan that specifies CMS quality control procedures.
|
§ 63.8(e) | CMS Performance Evaluation | No | Subpart QQQQQ does not require CMS performance evaluations.
|
§ 63.8(f)(1)-(5) | Alternative Monitoring Procedure | Yes
| |
§ 63.8(f)(6) | Relative Accuracy Test Audit (RATA) Alternative | No | Subpart QQQQQ does not require continuous emissions monitoring systems (CEMS).
|
§ 63.8(g)(1)-(5) | Data Reduction | No | Subpart QQQQQ specifies data reduction requirements.
|
§ 63.9(a)-(d), (h)-(j) | Notification Requirements | Yes | Except that subpart QQQQQ does not require performance tests or CMS performance evaluations.
|
§ 63.9(e) | Notification of Performance Test | No | Subpart QQQQQ does not require performance tests.
|
§ 63.9(f) | Notification of VE/Opacity Test | No | Subpart QQQQQ contains no opacity or VE limits.
|
§ 63.9(g) | Additional Notifications When Using CMS | No | Subpart QQQQQ does not require CMS performance evaluations.
|
§ 63.9(k) | Electronic reporting procedures | Yes | Only as specified in § 63.9(j).
|
§ 63.10(a), (b)(1), (d)(1), (d)(4), (e)(3), (f) | Recordkeeping and Reporting Requirements | Yes
| |
§ 63.10(b)(2)(i), (ii), (iv), (v) | Recordkeeping for Startup, Shutdown and Malfunction | No, for new or reconstructed sources which commenced construction or reconstruction after May 3, 2018. Yes, for all other affected sources before August 7, 2019, and No thereafter | See § 63.9545 for recordkeeping requirements.
|
§ 63.10(b)(2)(iii), (vi)-(xiv) | Owner/Operator Recordkeeping Requirements | Yes
| |
§ 63.10(c)(1)-(6), (9)-(15) | Additional Records for CMS | No | Subpart QQQQQ specifies record requirements.
|
§ 63.10(c)(7)-(8) | Records of Excess Emissions and Parameter Monitoring Exceedances for CMS | No | Subpart QQQQQ specifies record requirements.
|
§ 63.10(d)(2) | Reporting Results of Performance Tests | No | Subpart QQQQQ does not require performance tests.
|
§ 63.10(d)(3) | Reporting Opacity or VE Observations | No | Subpart QQQQQ contains no opacity or VE limits.
|
§ 63.10(d)(5) | SSM reports | No, for new or reconstructed sources which commenced construction or reconstruction after May 3, 2018. Yes, for all other affected sources before August 7, 2019, and No thereafter | See § 63.9540 for malfunction reporting requirements.
|
§ 63.10(e)(1)-(2) | Additional CMS Reports | No | Subpart QQQQQ does not require CMS.
|
§ 63.10(e)(4) | Reporting COMS Data | No | Subpart QQQQQ does not require COMS.
|
§ 63.11 | Control Device Requirements | No | Subpart QQQQQ does not require flares.
|
§§ 63.12-63.15 | Delegation, Addresses, Incorporation by Reference Availability of Information | Yes | |