If your EGU is in this subcategory . . .
| For the following
pollutants . . .
| You must meet the following emission limits and work practice standards . . .
| Using these requirements, as appropriate (e.g., specified sampling volume or test run duration) and limitations with the test methods in Table 5 to this Subpart . . .
|
---|
1. Coal-fired unit not low rank virgin coal | a. Filterable particulate matter (PM) | 9.0E-2 lb/MWh
1 | Collect a minimum catch of 6.0 milligrams or a minimum sample volume of 4 dscm per run.
|
| OR | OR
| |
| Total non-Hg HAP metals | 6.0E-2 lb/GWh | Collect a minimum of 4 dscm per run.
|
| OR | OR
| |
| Individual HAP metals: | | Collect a minimum of 3 dscm per run.
|
| Antimony (Sb) | 8.0E-3 lb/GWh
| |
| Arsenic (As) | 3.0E-3 lb/GWh
| |
| Beryllium (Be) | 6.0E-4 lb/GWh
| |
| Cadmium (Cd) | 4.0E-4 lb/GWh
| |
| Chromium (Cr) | 7.0E-3 lb/GWh
| |
| Cobalt (Co) | 2.0E-3 lb/GWh
| |
| Lead (Pb) | 2.0E-2 lb/GWh
| |
| Manganese (Mn) | 4.0E-3 lb/GWh
| |
| Nickel (Ni) | 4.0E-2 lb/GWh
| |
| Selenium (Se) | 5.0E-2 lb/GWh
| |
| b. Hydrogen chloride (HCl) | 1.0E-2 lb/MWh | For Method 26A at appendix A-8 to part 60 of this chapter, collect a minimum of 3 dscm per run. For ASTM D6348-03(Reapproved 2010)
2 or Method 320 at appendix A to part 63 of this chapter, sample for a minimum of 1 hour.
|
| OR
| | |
| Sulfur dioxide (SO2)
3 | 1.0 lb/MWh | SO2 CEMS.
|
| c. Mercury (Hg) | 3.0E-3 lb/GWh | Hg CEMS or sorbent trap monitoring system only.
|
2. Coal-fired units low rank virgin coal | a. Filterable particulate matter (PM) | 9.0E-2 lb/MWh
1 | Collect a minimum catch of 6.0 milligrams or a minimum sample volume of 4 dscm per run.
|
| OR | OR
| |
| Total non-Hg HAP metals | 6.0E-2 lb/GWh | Collect a minimum of 4 dscm per run.
|
| OR | OR
| |
| Individual HAP metals: | | Collect a minimum of 3 dscm per run.
|
| Antimony (Sb) | 8.0E-3 lb/GWh
| |
| Arsenic (As) | 3.0E-3 lb/GWh
| |
| Beryllium (Be) | 6.0E-4 lb/GWh
| |
| Cadmium (Cd) | 4.0E-4 lb/GWh
| |
| Chromium (Cr) | 7.0E-3 lb/GWh
| |
| Cobalt (Co) | 2.0E-3 lb/GWh
| |
| Lead (Pb) | 2.0E-2 lb/GWh
| |
| Manganese (Mn) | 4.0E-3 lb/GWh
| |
| Nickel (Ni) | 4.0E-2 lb/GWh
| |
| Selenium (Se) | 5.0E-2 lb/GWh
| |
| b. Hydrogen chloride (HCl) | 1.0E-2 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run For ASTM D6348-03(Reapproved 2010)
2 or Method 320, sample for a minimum of 1 hour.
|
| OR
| | |
| Sulfur dioxide (SO2)
3 | 1.0 lb/MWh | SO2 CEMS.
|
| c. Mercury (Hg) | Before July 8, 2024: 4.0E-2 lb/GWh; On or after July 8, 2024: 1.3E-2 lb/GWh | Hg CEMS or sorbent trap monitoring system only.
|
3. IGCC unit | a. Filterable particulate matter (PM) | 7.0E-2 lb/MWh
4 9.0E-2 lb/MWh
5 | Collect a minimum catch of 3.0 milligrams or a minimum sample volume of 2 dscm per run.
|
| OR | OR
| |
| Total non-Hg HAP metals | 4.0E-1 lb/GWh | Collect a minimum of 1 dscm per run.
|
| OR | OR
| |
| Individual HAP metals: | | Collect a minimum of 2 dscm per run.
|
| Antimony (Sb) | 2.0E-2 lb/GWh
| |
| Arsenic (As) | 2.0E-2 lb/GWh
| |
| Beryllium (Be) | 1.0E-3 lb/GWh
| |
| Cadmium (Cd) | 2.0E-3 lb/GWh
| |
| Chromium (Cr) | 4.0E-2 lb/GWh
| |
| Cobalt (Co) | 4.0E-3 lb/GWh
| |
| Lead (Pb) | 9.0E-3 lb/GWh
| |
| Manganese (Mn) | 2.0E-2 lb/GWh
| |
| Nickel (Ni) | 7.0E-2 lb/GWh
| |
| Selenium (Se) | 3.0E-1 lb/GWh
| |
| b. Hydrogen chloride (HCl) | 2.0E-3 lb/MWh | For Method 26A, collect a minimum of 1 dscm per run; for Method 26 at appendix A-8 to part 60 of this chapter, collect a minimum of 120 liters per run.
For ASTM D6348-03(Reapproved 2010)
2 or Method 320, sample for a minimum of 1 hour.
|
| OR
| | |
| Sulfur dioxide (SO2)
3 | 4.0E-1 lb/MWh | SO2 CEMS.
|
| c. Mercury (Hg) | 3.0E-3 lb/GWh | Hg CEMS or sorbent trap monitoring system only.
|
4. Liquid oil-fired unit—continental (excluding limited-use liquid oil-fired subcategory units) | a. Filterable particulate matter (PM) | 3.0E-1 lb/MWh
1 | Collect a minimum of 1 dscm per run.
|
| OR | OR
| |
| Total HAP metals | 2.0E-4 lb/MWh | Collect a minimum of 2 dscm per run.
|
| OR | OR
| |
| Individual HAP metals: | | Collect a minimum of 2 dscm per run.
|
| Antimony (Sb) | 1.0E-2 lb/GWh
| |
| Arsenic (As) | 3.0E-3 lb/GWh
| |
| Beryllium (Be) | 5.0E-4 lb/GWh
| |
| Cadmium (Cd) | 2.0E-4 lb/GWh
| |
| Chromium (Cr) | 2.0E-2 lb/GWh
| |
| Cobalt (Co) | 3.0E-2 lb/GWh
| |
| Lead (Pb) | 8.0E-3 lb/GWh
| |
| Manganese (Mn) | 2.0E-2 lb/GWh
| |
| Nickel (Ni) | 9.0E-2 lb/GWh
| |
| Selenium (Se) | 2.0E-2 lb/GWh
| |
| Mercury (Hg) | 1.0E-4 lb/GWh | For Method 30B at appendix A-8 to part 60 of this chapter sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be <
1/2 the standard.
|
| b. Hydrogen chloride (HCl) | 4.0E-4 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03(Reapproved 2010)
2 or Method 320, sample for a minimum of 1 hour.
|
| c. Hydrogen fluoride (HF) | 4.0E-4 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03 (Reapproved 2010)
2 or Method 320, sample for a minimum of 1 hour.
|
5. Liquid oil-fired unit—non-continental (excluding limited-use liquid oil-fired subcategory units) | a. Filterable particulate matter (PM) | 2.0E-1 lb/MWh
1 | Collect a minimum of 1 dscm per run.
|
| OR | OR
| |
| Total HAP metals | 7.0E-3 lb/MWh | Collect a minimum of 1 dscm per run.
|
| OR | OR
| |
| Individual HAP metals: | | Collect a minimum of 3 dscm per run.
|
| Antimony (Sb) | 8.0E-3 lb/GWh
| |
| Arsenic (As) | 6.0E-2 lb/GWh
| |
| Beryllium (Be) | 2.0E-3 lb/GWh
| |
| Cadmium (Cd) | 2.0E-3 lb/GWh
| |
| Chromium (Cr) | 2.0E-2 lb/GWh
| |
| Cobalt (Co) | 3.0E-1 lb/GWh
| |
| Lead (Pb) | 3.0E-2 lb/GWh
| |
| Manganese (Mn) | 1.0E-1 lb/GWh
| |
| Nickel (Ni) | 4.1E0 lb/GWh
| |
| Selenium (Se) | 2.0E-2 lb/GWh
| |
| Mercury (Hg) | 4.0E-4 lb/GWh | For Method 30B sample volume determination (Section 8.2.4), the estimated Hg concentration should nominally be <
1/2 the standard.
|
| b. Hydrogen chloride (HCl) | 2.0E-3 lb/MWh | For Method 26A, collect a minimum of 1 dscm per run; for Method 26, collect a minimum of 120 liters per run. For ASTM D6348-03 (Reapproved 2010)
2 or Method 320, sample for a minimum of 1 hour.
|
| c. Hydrogen fluoride (HF) | 5.0E-4 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03 (Reapproved 2010)
2 or Method 320, sample for a minimum of 1 hour.
|
6. Solid oil-derived fuel-fired unit | a. Filterable particulate matter (PM) | 3.0E-2 lb/MWh
1 | Collect a minimum of 1 dscm per run.
|
| OR | OR
| |
| Total non-Hg HAP metals | 6.0E-1 lb/GWh | Collect a minimum of 1 dscm per run.
|
| OR | OR
| |
| Individual HAP metals: | | Collect a minimum of 3 dscm per run.
|
| Antimony (Sb) | 8.0E-3 lb/GWh
| |
| Arsenic (As) | 3.0E-3 lb/GWh
| |
| Beryllium (Be) | 6.0E-4 lb/GWh
| |
| Cadmium (Cd) | 7.0E-4 lb/GWh
| |
| Chromium (Cr) | 6.0E-3 lb/GWh
| |
| Cobalt (Co) | 2.0E-3 lb/GWh
| |
| Lead (Pb) | 2.0E-2 lb/GWh
| |
| Manganese (Mn) | 7.0E-3 lb/GWh
| |
| Nickel (Ni) | 4.0E-2 lb/GWh
| |
| Selenium (Se) | 6.0E-3 lb/GWh
| |
| b. Hydrogen chloride (HCl) | 4.0E-4 lb/MWh | For Method 26A, collect a minimum of 3 dscm per run. For ASTM D6348-03 (Reapproved 2010)
2 or Method 320, sample for a minimum of 1 hour.
|
| OR
| | |
| Sulfur dioxide (SO2)
3 | 1.0 lb/MWh | SO2 CEMS.
|
| c. Mercury (Hg) | 2.0E-3 lb/GWh | Hg CEMS or Sorbent trap monitoring system only.
|