Regulations last checked for updates: Feb 21, 2025

Title 40 - Protection of Environment last revised: Nov 21, 2025
Appendix - Table I-18 to Subpart I of Part 98—Default Factors for Gamma (gi,p and gk,i,p) for Semiconductor Manufacturing and for MEMS and PV Manufacturing Under Certain Conditions * for Use With the Stack Testing Method

Table I-18 to Subpart I of Part 98—Default Factors for Gamma (gi,p and gk,i,p) for Semiconductor Manufacturing and for MEMS and PV Manufacturing Under Certain Conditions * for Use With the Stack Testing Method

Process type In-situ thermal or in-situ plasma cleaning Remote plasma cleaning
Gas CF4 C2F6 c-C4F8 NF3 SF6 C3F8 CF4 NF3
If manufacturing wafer sizes ≤200 mm AND manufacturing 300 mm (or greater) wafer sizes
gi139.34.71411NANA5.7
gCF4,iNA236.7638.7NANA58
gC2F6,iNANANANA3.4NANANA
gCHF3,iNANANANANANANA0.24
gCH2F2,iNANANANANANANA111
gCH3F,iNANANANANANANA33
If manufacturing ≤200 mm OR manufacturing 300 mm (or greater) wafer sizes
gi (≤ 200 mm wafer size)139.34.72.911NANA1.4
gCF4,i (≤200 mm wafer size)NA236.71108.7NANA36
gC2F6,i (≤200 mm wafer size)NANANANA3.4NANANA
gi (300 mm wafer size)NANANA26NANANA10
gCF4,i (300 mm wafer size)NANANA17NANANA80
gC2F6,i (300 mm wafer size)NANANANANANANANA
gCHF3,i (300 mm wafer size)NANANANANANANA0.24
gCH2F2,i (300 mm wafer size)NANANANANANANA111
gCH3F,i (300 mm wafer size)NANANANANANANA33

* If you manufacture MEMS or PVs and use semiconductor tools and processes, you may use the corresponding g in this table. For all other tools and processes, a default g of 10 must be used.

[89 FR 31922, Apr. 25, 2024]
source: 74 FR 56374, Oct. 30, 2009, unless otherwise noted.