Regulations last checked for updates: Nov 25, 2024

Title 40 - Protection of Environment last revised: Nov 21, 2024
Appendix - Table W-5A to Subpart W of Part 98—Default Methane Leaker Emission Factors for Liquefied Natural Gas (LNG) Storage
Link to an amendment published at 89 FR 42326, May 14, 2024.
LNG storage Emission factor
(scf/hour/component)
If you survey using any of the methods in § 98.234(a)(1)
through (6)
If you survey using Method 21 as
specified in
§ 98.234(a)(7)
Leaker Emission Factors—LNG Storage Components, LNG Service
Valve1.190.23
Pump Seal4.000.73
Connector0.340.11
Other 11.770.99
Leaker Emission Factors—LNG Storage Components, Gas Service
Valve 214.849.51
Connector5.593.58
Open-Ended Line17.2711.07
Pressure Relief Valve39.6625.42
Meter and Instrument19.3312.39
Other 34.12.63

1 “Other” equipment type for components in LNG service should be applied for any equipment type other than connectors, pumps, or valves.

2 Valves include control valves, block valves and regulator valves.

3 “Other” equipment type for components in gas service should be applied for any equipment type other than valves, connectors, flanges, open-ended lines, pressure relief valves, and meters and instruments, as specified in § 98.232(g)(6) and (7).

[81 FR 86518, Nov. 30, 2016]
source: 74 FR 56374, Oct. 30, 2009, unless otherwise noted.