(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS):

Pollutant or pollutant property NSPS Effluent Limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed
Metric units (kilograms per 1,000 m 3 of feedstock)
BOD521.811.6
TSS14.99.5
COD 1133.069.0
Oil and grease6.63.5
Phenolic compounds0.158.077
Ammonia as N23.410.7
Sulfide0.1400.063
Total chromium0.320.19
Hexavalent chromium0.0250.012
pH( 2)( 2)
English units (pounds per 1,000 bbl of feedstock)
BOD57.74.1
TSS5.23.3
COD 147.024.0
Oil and grease2.41.3
Phenolic compounds0.0560.027
Ammonia as N8.33.8
Sulfide0.0500.022
Total chromium0.1160.068
Hexavalent chromium0.00960.0044
pH( 2)( 2)

1 See footnote following table in § 419.13(d).

2 Within the range of 6.0 to 9.0.

(b) The limits set forth in paragraph (a) of this section are to be multiplied by the following factors to calculate the maximum for any one day and maximum average of daily values for thirty consecutive days.

(1) Size factor.

1,000 bbl of feedstock per stream day Size factor
Less than 24.90.73
25.0 to 49.90.76
50.0 to 74.90.83
75.0 to 99.90.91
100.0 to 124.90.99
125.0 to 149.91.08
150.0 or greater1.13

(2) Process factor.

Process configuration Process factor
Less than 4.490.73
4.5 to 5.490.80
5.5 to 5.990.91
6.0 to 6.490.99
6.5 to 6.991.08
7.0 to 7.491.17
7.5 to 7.991.28
8.0 to 8.491.39
8.5 to 8.991.51
9.0 to 9.491.65
9.5 or greater1.72

(3) See the comprehensive example in subpart D, § 419.42(b)(3).

(c) The provisions of § 419.16(c) apply to discharges of process wastewater pollutants attributable to ballast water by a point source subject to the provisions of this subpart.

(d) The quantity and quality of pollutants or pollutant properties controlled by this paragraph, attributable to once-through cooling water, are excluded from the discharge allowed by paragraph (b) of this section. Once-through cooling water may be discharged with a total organic carbon concentration not to exceed 5 mg/l.

(e) Effluent limitations for runoff. [Reserved]

[47 FR 46446, Oct. 18, 1982, as amended at 50 FR 28523, July 12, 1985; 50 FR 32414, Aug. 12, 1985]
authority: Secs. 301, 304 (b), (c), (e), and (g), 306 (b) and (c), 307 (b) and (c), and 501 of the Clean Water Act (the Federal Water Pollution Control Act Amendments of 1972 as amended by the Clean Water Act of 1977) (the “Act”); 33 U.S.C. 1311,1314,c,e,and, 1316 (b) andc, 1317 (b) andc,and; 86 Stat. 816, Pub. L. 92-500; 91 Stat. 1567, Pub. L. 95-217
source: 47 FR 46446, Oct. 18, 1982, unless otherwise noted.
cite as: 40 CFR 419.36