Except as provided in 40 CFR 403.7 and 403.13, any existing source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for existing sources.
(a) Iron blast furnace.
Pollutant or pollutant property
| Pretreatment standards for existing sources
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (pounds per 1,000 lb) of products
|
Ammonia-N
1 | 0.00876 | 0.00292
|
Cyanide | 0.00175 | 0.000876
|
Phenols (4AAP) | 0.0000584 | 0.0000292
|
Lead | 0.000263 | 0.0000876
|
Zinc | 0.000394 | 0.000131
|
(b) [Reserved]
(c) Existing indirect dischargers.
Pollutant or pollutant property
| Pretreatment standards for existing sources
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days
|
---|
| Kg/kkg (pounds per 1,000 lb) of product
|
Ammonia-N | 0.0350 | 0.0175
|
Cyanide | 0.00175 | 0.000876
|
Phenols (4AAP) | 0.000175 | 0.0000584
|
Lead | 0.000263 | 0.0000876
|
Zinc | 0.000394 | 0.000131 |
[47 FR 23284, May 27, 1982, as amended at 49 FR 21030, May 17, 1984; 67 FR 64266, Oct. 17, 2002]