Regulations last checked for updates: Nov 24, 2024

Title 40 - Protection of Environment last revised: Nov 21, 2024
§ 424.25 - Standards of performance for new sources.

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

Effluent characteristic Effluent limitations
Maximum for any 1 day Average of daily values for 30 consecutive days shall not exceed—
Metric units (kg/Mwh)
TSS0.0320.016
Chromium total.001.0005
Chromium VI.0001.00005
Manganese total.011.005
Cyanide total.0005.0003
Phenols.0004.0002
pH( 1)( 1)
English units (lb/Mwh)
TSS.071.035
Chromium total.002.0012
Chromium VI.0002.0001
Manganese total.023.012
Cyanide total.001.0006
Phenols.0009.0005
pH( 1)( 1)

1 Within the range 6.0 to 9.0.

Provided, however, That for nonelectric furnace smelting processes, the units of effluent limitations set forth in this section shall be read as “kg/kkg of product” rather than “kg/Mwh,” and the limitations (except for pH) shall be 3.3 times those listed in the table in this section (or, for English units, “lb/ton of product” rather than “lb/Mwh,” and the limitations (except for pH) shall be three times those listed in the table). [39 FR 6809, Feb. 22, 1974, as amended at 39 FR 17841, May 21, 1974]
authority: Secs. 301, 304(b) and (c), 306(b) and (c), 307(c) of the Federal Water Pollution Control Act, as amended; 33 U.S.C. 1251,1311,1314,1316,1317; 86 Stat. 816
source: 39 FR 6809, Feb. 22, 1974, unless otherwise noted.
cite as: 40 CFR 424.25