Regulations last checked for updates: Nov 25, 2024

Title 40 - Protection of Environment last revised: Nov 21, 2024
§ 425.41 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT).

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

Pollutant or pollutant property BPT limitations
Maximum for any 1 day Maximum for monthly average
Kg/kkg (or pounds per 1,000 pounds) of raw material
BOD58.94.0
TSS12.85.8
Oil & Grease3.71.7
Total Chromium0.230.08
pH( 1)( 1)

1 Within the range of 6.0 to 9.0.

[47 FR 52870, Nov. 23, 1982, as amended at 53 FR 9182, Mar. 21, 1988]
authority: 33 U.S.C. 1311,1314,c,e, 1316 (b) andc, 1317 (b) andc,1318
source: 47 FR 52870, Nov. 23, 1982, unless otherwise noted.
cite as: 40 CFR 425.41