The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart (the fluoride and lead limitations are applicable to the abrasive polishing and acid polishing waste water streams while the TSS, oil, and pH limitations are applicable to the entire process waste water stream):
Effluent characteristic
| Effluent limitations
|
---|
Maximum for any 1 day
| Average of daily values for 30 consecutive days shall not exceed—
|
---|
| Metric units (g/kkg of furnace pull)
|
Oil | 260.0 | 130.0
|
TSS | 260.0 | 130.0
|
Fluoride | 120.0 | 60.0
|
Lead | 30.9 | 0.45
|
pH | (
1) | (
1)
|
| English units (lb/1,000 lb of furnace pull)
|
Oil | 0.26 | 0.13
|
TSS | 0.26 | 0.13
|
Fluoride | 0.12 | 0.06
|
Lead | 0.0009 | 0.00045
|
pH | (
1) | (
1)
|
authority: Secs. 301, 304 (b) and (c), 306 (b) and (c), 307(c), and 316(b) of the Federal Water Pollution Control Act, as amended;
33 U.S.C. 1251,
1311,
1314,
1316,
1317; 86 Stat. 816
source: 39 FR 2565, Jan. 22, 1974, unless otherwise noted.
cite as: 40 CFR 426.115