Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart where chlorophenolic-containing biocides are used must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable (BAT). Non-continuous dischargers shall not be subject to the maximum day mass limitations in kg/kkg (lb/1000 lb), but shall be subject to concentration limitations. Concentration limitations are only applicable to non-continuous dischargers. Permittees not using chlorophenolic-containing biocides must certify to the permit-issuing authority that they are not using these biocides:
Subpart C
[BAT effluent limitations for unbleached kraft facilities]
Pollutant or pollutant property
| Maximum for any 1 day
|
---|
Kg/kkg (or pounds per 1,000 lb) of product
| Milligrams/liter
|
---|
Pentachlorophenol | 0.00058 | (0.011)(12.6)/y
|
Trichlorophenol | 0.00053 | (0.010)(12.6)/y
|
y = wastewater discharged in kgal per ton of product. | | |
Subpart C
[BAT effluent limitations for unbleached kraft facilities where pulp and paper are produced using the unbleached kraft-neutral sulfite semi-chemical (cross recovery) process and/or a combined unbleached kraft and semi-chemical process, wherein the spent semi-chemical cooking liquor is burned within the unbleached kraft chemical recovery system]
Pollutant or pollutant property
| Maximum for any 1 day
|
---|
Kg/kkg (or pounds per 1,000 lb) of product
| Milligrams/liter
|
---|
Pentachlorophenol | 0.00064 | (0.011)(14.0)/y
|
Trichlorophenol | 0.00059 | (0.010)(14.0)/y
|
y = wastewater discharged in kgal per ton of product. | | |
authority: Sections 301, 304, 306, 307, 308, 402, and 501 of the Clean Water Act, as amended, (
33 U.S.C. 1311,
1314,
1316,
1317,
1318,
1342,
and,
and,
as.S.C. 7412)
source: 63 FR 18635, Apr. 15, 1998, unless otherwise noted.
cite as: 40 CFR 430.34