(a) The following duty cycle applies for discrete-mode testing:
E4 Mode No.
| Engine
speed
1
| Torque
(percent)
2
| Weighting
factors
|
---|
1 | Maximum test speed | 100 | 0.06
|
2 | 80% | 71.6 | 0.14
|
3 | 60% | 46.5 | 0.15
|
4 | 40% | 25.3 | 0.25
|
5 | Warm idle | 0 | 0.40
|
(b) The following duty cycle applies for ramped-modal testing:
RMC Mode
| Time in mode
(seconds)
| Engine speed
1 2
| Torque (percent)
2 3
|
---|
1a Steady-state | 225 | Idle | 0
|
1b Transition | 20 | Linear transition | Linear transition
|
2a Steady-state | 63 | Maximum test speed | 100
|
2b Transition | 20 | Linear transition | Linear transition
|
*3a Steady-state | 271 | 40% | 25.3%
|
3b Transition | 20 | Linear transition | Linear transition
|
4a Steady-state | 151 | 80% | 71.6%
|
4b Transition | 20 | Linear transition | Linear transition
|
5a Steady-state | 161 | 60% | 46.5%
|
5b Transition | 20 | Linear transition | Linear transition
|
6 Steady-state | 229 | Warm idle | 0
|