REGULATIONS
Rulings
AD/CVD
Notices
HTSUS
U.S. Code
Regs
More
Ports
About
Updates
Apps
Larger font
Smaller font
SEARCH
Sort by Rank
Titles Ascending
Titles Descending
10 per page
25 Result/page
50 Result/page
Regulations last checked for updates: Feb 22, 2025
Title 40 - Protection of Environment last revised: Nov 22, 2025
All Titles
Title 40
Chapter I
Part 53
Subpart B
Appendix - Table B-4 to Subpart B of Part 53—Line Voltage and Room Temperature Test Conditions
View all text of [None - None]
Appendix - Table B-4 to Subpart B of Part 53—Line Voltage and Room Temperature Test Conditions
Test day
Line
voltage,
1
rms
Room
temperature,
2
°C
Comments
0
115
25
Initial set-up and adjustments.
1
125
20
2
105
20
3
125
30
Adjustments and/or periodic maintenance permitted at end of tests.
4
105
30
5
125
20
6
105
20
Adjustments and/or periodic maintenance permitted at end of tests.
7
125
30
Examine test results to ascertain if further testing is required.
8
105
30
9
125
20
Adjustments and/or periodic maintenance permitted at end of tests.
10
105
20
11
125
30
12
105
30
Adjustments and/or periodic maintenance permitted at end of tests.
13
125
20
14
105
20
15
125
30
1
Voltage specified shall be controlled to ±1 volt.
2
Temperatures shall be controlled to ±1 °C.