Regulations last checked for updates: Nov 22, 2024

Title 40 - Protection of Environment last revised: Nov 20, 2024
Appendix - Table 8 to Subpart CCCC of Part 60—Emission Limitations for Small, Remote Incinerators That Commenced Construction After June 4, 2010, or That Commenced Reconstruction or Modification After August 7, 2013
For the air pollutant You must meet this
emission limitation 1
Using this averaging time 2 And determining compliance
using this method 2
Cadmium0.67 milligrams per dry standard cubic meter3-run average (collect a minimum volume of 1 dry standard cubic meters per run)Performance test (Method 29 at 40 CFR part 60, appendix A-8).
Carbon monoxide13 parts per million dry volume3-run average (1 hour minimum sample time per run)Performance test (Method 10 at 40 CFR part 60, appendix A-4).
Dioxins/furans (total mass basis)1,800 nanograms per dry standard cubic meter3-run average (collect a minimum volume of 1 dry standard cubic meters per run)Performance test (Method 23 at 40 CFR part 60, appendix A-7).
Dioxins/furans (toxic equivalency basis)31 nanograms per dry standard cubic meter3-run average (collect a minimum volume of 1 dry standard cubic meters)Performance test (Method 23 at 40 CFR part 60, appendix A-7).
Fugitive ashVisible emissions for no more than 5 percent of the hourly observation periodThree 1-hour observation periodsVisible emissions test (Method 22 at 40 CFR part 60, appendix A-7).
Hydrogen chloride200 parts per million by dry volume3-run average (For Method 26, collect a minimum volume of 60 liters per run. For Method 26A, collect a minimum volume of 1 dry standard cubic meter per run)Performance test (Method 26 or 26A at 40 CFR part 60, appendix A-8).
Lead2.0 milligrams per dry standard cubic meter3-run average (collect a minimum volume of 1 dry standard cubic meters)Performance test (Method 29 at 40 CFR part 60, appendix A-8). Use ICPMS for the analytical finish.
Mercury0.0035 milligrams per dry standard cubic meter3-run average (For Method 29 and ASTM D6784-02 (Reapproved 2008) 2, collect a minimum volume of 2 dry standard cubic meters per run. For Method 30B, collect a minimum volume as specified in Method 30B at 40 CFR part 60, appendix A)Performance test (Method 29 or 30B at 40 CFR part 60, appendix A-8) or ASTM D6784-02 (Reapproved 2008). 3
Nitrogen oxides170 parts per million dry volume3-run average (for Method 7E, 1 hour minimum sample time per run)Performance test (Method 7 or 7E at 40 CFR part 60, appendix A-4).
Particulate matter (filterable)270 milligrams per dry standard cubic meter3-run average (collect a minimum volume of 1 dry standard cubic meters)Performance test (Method 5 or 29 at 40 CFR part 60, appendix A-3 or appendix A-8).
Sulfur dioxide1.2 parts per million dry volume3-run average (1 hour minimum sample time per run)Performance test (Method 6 or 6c at 40 CFR part 60, appendix A-4).

1 All emission limitations are measured at 7 percent oxygen, dry basis at standard conditions. For dioxins/furans, you must meet either the Total Mass Basis limit or the toxic equivalency basis limit.

2 In lieu of performance testing, you may use a CEMS or, for mercury, an integrated sorbent trap monitoring system to demonstrate initial and continuing compliance with an emissions limit, as long as you comply with the CEMS or integrated sorbent trap monitoring system requirements applicable to the specific pollutant in §§ 60.2145 and 60.2165. As prescribed in § 60.2145(u), if you use a CEMS or an integrated sorbent trap monitoring system to demonstrate compliance with an emissions limit, your averaging time is a 30-day rolling average of 1-hour arithmetic average emission concentrations.

3 Incorporated by reference, see § 60.17.

authority: 42 U.S.C. 7401
source: 36 FR 24877, Dec. 23, 1971, unless otherwise noted.