INTRODUCTION
§ 60.2500 - What is the purpose of this subpart?
§ 60.2505 - Am I affected by this subpart?
§ 60.2510 - Is a state plan required for all states?
§ 60.2515 - What must I include in my state plan?
§ 60.2520 - Is there an approval process for my state plan?
§ 60.2525 - What if my state plan is not approvable?
§ 60.2530 - Is there an approval process for a negative declaration letter?
§ 60.2535 - What compliance schedule must I include in my state plan?
§ 60.2540 - Are there any state plan requirements for this subpart that apply instead of the requirements specified in subpart B?
§ 60.2541 - In lieu of a state plan submittal, are there other acceptable option(s) for a state to meet its Clean Air Act section 111(d)/129(b)(2) obligations?
§ 60.2542 - What authorities will not be delegated to state, local, or tribal agencies?
§ 60.2545 - Does this subpart directly affect CISWI owners and operators in my state?
APPLICABILITY OF STATE PLANS
§ 60.2550 - What CISWIs must I address in my state plan?
§ 60.2555 - What combustion units are exempt from my state plan?
USE OF MODEL RULE
§ 60.2560 - What is the “model rule” in this subpart?
§ 60.2565 - How does the model rule relate to the required elements of my state plan?
§ 60.2570 - What are the principal components of the model rule?
MODEL RULE—INCREMENTS OF PROGRESS
§ 60.2575 - What are my requirements for meeting increments of progress and achieving final compliance?
§ 60.2580 - When must I complete each increment of progress?
§ 60.2585 - What must I include in the notifications of achievement of increments of progress?
§ 60.2590 - When must I submit the notifications of achievement of increments of progress?
§ 60.2595 - What if I do not meet an increment of progress?
§ 60.2600 - How do I comply with the increment of progress for submittal of a control plan?
§ 60.2605 - How do I comply with the increment of progress for achieving final compliance?
§ 60.2610 - What must I do if I close my CISWI and then restart it?
§ 60.2615 - What must I do if I plan to permanently close my CISWI and not restart it?
MODEL RULE—WASTE MANAGEMENT PLAN
§ 60.2620 - What is a waste management plan?
§ 60.2625 - When must I submit my waste management plan?
§ 60.2630 - What should I include in my waste management plan?
MODEL RULE—OPERATOR TRAINING AND QUALIFICATION
§ 60.2635 - What are the operator training and qualification requirements?
§ 60.2640 - When must the operator training course be completed?
§ 60.2645 - How do I obtain my operator qualification?
§ 60.2650 - How do I maintain my operator qualification?
§ 60.2655 - How do I renew my lapsed operator qualification?
§ 60.2660 - What site-specific documentation is required?
§ 60.2665 - What if all the qualified operators are temporarily not accessible?
MODEL RULE—EMISSION LIMITATIONS AND OPERATING LIMITS
§ 60.2670 - What emission limitations must I meet and by when?
§ 60.2675 - What operating limits must I meet and by when?
§ 60.2680 - What if I do not use a wet scrubber, fabric filter, activated carbon injection, selective noncatalytic reduction, an electrostatic precipitator, or a dry scrubber to comply with the emission limitations?
MODEL RULE—PERFORMANCE TESTING
§ 60.2690 - How do I conduct the initial and annual performance test?
§ 60.2695 - How are the performance test data used?
MODEL RULE—INITIAL COMPLIANCE REQUIREMENTS
§ 60.2700 - How do I demonstrate initial compliance with the amended emission limitations and establish the operating limits?
§ 60.2705 - By what date must I conduct the initial performance test?
§ 60.2706 - By what date must I conduct the initial air pollution control device inspection?
MODEL RULE—CONTINUOUS COMPLIANCE REQUIREMENTS
§ 60.2710 - How do I demonstrate continuous compliance with the amended emission limitations and the operating limits?
§ 60.2715 - By what date must I conduct the annual performance test?
§ 60.2716 - By what date must I conduct the annual air pollution control device inspection?
§ 60.2720 - May I conduct performance testing less often?
§ 60.2725 - May I conduct a repeat performance test to establish new operating limits?
MODEL RULE—MONITORING
§ 60.2730 - What monitoring equipment must I install and what parameters must I monitor?
§ 60.2735 - Is there a minimum amount of monitoring data I must obtain?
MODEL RULE—RECORDKEEPING AND REPORTING
§ 60.2740 - What records must I keep?
§ 60.2745 - Where and in what format must I keep my records?
§ 60.2750 - What reports must I submit?
§ 60.2755 - When must I submit my waste management plan?
§ 60.2760 - What information must I submit following my initial performance test?
§ 60.2765 - When must I submit my annual report?
§ 60.2770 - What information must I include in my annual report?
§ 60.2775 - What else must I report if I have a deviation from the operating limits or the emission limitations?
§ 60.2780 - What must I include in the deviation report?
§ 60.2785 - What else must I report if I have a deviation from the requirement to have a qualified operator accessible?
§ 60.2790 - Are there any other notifications or reports that I must submit?
§ 60.2795 - In what form can I submit my reports?
§ 60.2800 - Can reporting dates be changed?
MODEL RULE—TITLE V OPERATING PERMITS
§ 60.2805 - Am I required to apply for and obtain a Title V operating permit for my unit?
MODEL RULE—AIR CURTAIN INCINERATORS (ACIS)
§ 60.2810 - What is an air curtain incinerator?
§ 60.2815 - What are my requirements for meeting increments of progress and achieving final compliance?
§ 60.2820 - When must I complete each increment of progress?
§ 60.2825 - What must I include in the notifications of achievement of increments of progress?
§ 60.2830 - When must I submit the notifications of achievement of increments of progress?
§ 60.2835 - What if I do not meet an increment of progress?
§ 60.2840 - How do I comply with the increment of progress for submittal of a control plan?
§ 60.2845 - How do I comply with the increment of progress for achieving final compliance?
§ 60.2850 - What must I do if I close my air curtain incinerator and then restart it?
§ 60.2855 - What must I do if I plan to permanently close my air curtain incinerator and not restart it?
§ 60.2860 - What are the emission limitations for air curtain incinerators?
§ 60.2865 - How must I monitor opacity for air curtain incinerators?
§ 60.2870 - What are the recordkeeping and reporting requirements for air curtain incinerators?
MODEL RULE—DEFINITIONS
§ 60.2875 - What definitions must I know?
Appendix - Table 1 to Subpart DDDD of Part 60—Model Rule—Increments of Progress and Compliance Schedules
Appendix -
Appendix - Table 3 to Subpart DDDD of Part 60—Model Rule—Operating Limits for Wet Scrubbers
Appendix - Table 4 to Subpart DDDD of Part 60—Model Rule—Toxic Equivalency Factors
Appendix - Table 5 to Subpart DDDD of Part 60—Model Rule—Summary of Reporting Requirements 1
Appendix -
Appendix - Table 7 to Subpart DDDD of Part 60—Model Rule—Emission Limitations That Apply to Energy Recovery Units After May 20, 2011
Appendix - Table 8 to Subpart DDDD of Part 60—Model Rule—Emission Limitations That Apply to Waste-Burning Kilns After May 20, 2011
Appendix - Table 9 to Subpart DDDD of Part 60—Model Rule—Emission Limitations That Apply to Small, Remote Incinerators After May 20, 2011 [Date To Be Specified in State Plan] 1
authority:
42 U.S.C. 7401
source:
36 FR 24877, Dec. 23, 1971, unless otherwise noted.