As stated in § 60.2916, you must comply with the following:
For these operating
parameters
| You must establish these operating limits
| And monitoring using these minimum frequencies
|
---|
Data measurement
| Data recording
| Averaging time
|
---|
1. Charge rate | Maximum charge rate | Continuous | Every hour | Daily for batch units. 3-hour rolling for continuous and intermittent units
a.
|
2. Pressure drop across the wet scrubber or amperage to wet scrubber | Minimum pressure drop or amperage | Continuous | Every 15 minutes | 3-hour rolling
a.
|
3. Scrubber liquor flow rate | Minimum flow rate | Continuous | Every 15 minutes | 3-hour rolling
a.
|
4. Scrubber liquor pH | Minimum pH | Continuous | Every 15 minutes | 3-hour rolling
a.
|