Appendix - Tables to Subpart I of Part 84

Table 5—Canister Bench Tests and Requirements for Front-Mounted and Back-Mounted Gas Mask Canisters

[42 CFR part 84, subpart I]

Canister type Test condition Test atmosphere Number of tests Maximum allowable penetratin (parts per million) Minimum service life (minutes) 1
Gas or vapor Concentration (parts per million) Flow rate (liters per minute)
Acid gasAs receivedSO220,000643512
EquilibratedCl220,000643512
SO220,000324512
Cl220,000324512
Organic vaporAs receivedCCl420,000643512
EquilibratedCCl420,000324512
AmmoniaAs receivedNH330,0006435012
EquilibratedNH330,0003245012
Carbon monoxideAs receivedCO20,000 4 642( 3)60
EquilibratedCO5,000 2 323( 3)60
CO3,000 2 323( 3)60
Combination of 2 or 3 of above types 5
Combination of all above types 6

1 Minimum life will be determined at the indicated penetration.

2 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere will be 25 ±2.5 °C.

3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time.

4 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C.

5 Test conditions and requirements will be applicable as shown in this table.

6 Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and ammonia will be 6 min instead of 12 min.

Table 6—Canister Bench Tests and Requirements for Chin-Style Gas Mask Canisters

[42 CFR part 84, subpart I]

Canister type Test condition Test atmosphere Number of tests Maximum allowable penetration (parts per million) Minimum service life (minutes) 1
Gas or vapor Concentration (parts per million) Flow rate (liters per minute)
Acid gasAs received EquilibratedSO250,000643512
Cl25,000643512
SO25,000324512
Cl25,000324512
Organic vaporAs received EquilibratedCCl45,000643512
CCl45,000324512
AmmoniaAs received EquilibratedNH35,0006435012
As received EquilibratedNH35,0003245012
Carbon monoxideAs receivedCO20,000 2 642( 3)60
CO5,000 4 323( 3)60
CO3,000 2 323( 3)60
Combination of 2 or 3 of above types 5
Combination of all above types 6

1 Minimum life will be determined at the indicated penetration.

2 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere will be 25 ±2.5 °C.

3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time.

4 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C.

5 Test conditions and requirements will be applicable as shown in this table.

6 Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and ammonia will be 6 min instead of 12 min.

Table 7—Canister Bench Tests and Requirements for Escape Gas Mask Canisters

[42 CFR part 84, subpart I]

Canister type Test condition Test atmosphere Number of tests Maximum allowable penetration (parts per million) Minimum service life (minutes) 1
Gas or vapor Concentration (parts per million) Flow rate (liters per minute)
Acid gasAs receivedSO25,000643512
EquilibratedCl25,000643512
SO25,000324512
Cl25,000324512
Organic vaporAs receivedCCl45,000643512
EquilibratedCCl45,000324512
AmmoniaAs receivedNH35,0006435012
EquilibratedNH35,0003245012
Carbon monoxideAs receivedCO10,000 2 322( 3) 4 60
CO5,000 5 323( 3)60
CO3,000 2 323( 3)60

1 Minimum life will be determined at the indicated penetration.

2 Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere will be 25 ±2.5 °C.

3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time.

4 If effluent temperature exceeds 100 °C during this test, the escape gas mask shall be equipped with an effective heat exchanger.

5 Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C.

authority: 29 U.S.C. 651
source: 60 FR 30355, June 8, 1995, unless otherwise noted.