Table 5—Canister Bench Tests and Requirements for Front-Mounted and Back-Mounted Gas Mask Canisters
[42 CFR part 84, subpart I]
1 Minimum life will be determined at the indicated penetration.
2 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere will be 25 ±2.5 °C.
3 Maximum allowable CO penetration will be 385 cm 3 during the minimum life. The penetration shall not exceed 500 p/m during this time.
4 Relative humidity of test atmosphere will be 95 ±3pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C.
5 Test conditions and requirements will be applicable as shown in this table.
6 Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and ammonia will be 6 min instead of 12 min.
Table 6—Canister Bench Tests and Requirements for Chin-Style Gas Mask Canisters
Table 7—Canister Bench Tests and Requirements for Escape Gas Mask Canisters
2 Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere will be 25 ±2.5 °C.
4 If effluent temperature exceeds 100 °C during this test, the escape gas mask shall be equipped with an effective heat exchanger.
5 Relative humidity of test atmosphere will be 95 ±3 pct; temperature of test atmosphere entering the test fixture will be 0 ±2.5 °C−0 °C.