Regulations last checked for updates: Nov 25, 2024
Title 24 - Housing and Urban Development last revised: Nov 13, 2024
§ 242.44 - Construction standards.
Work designed and performed under this section shall conform to the standards adopted by HUD, which, at a minimum, shall include the “Guidelines for Construction and Equipment of Hospital and Medical Facilities,” which is regularly updated and published by the American Institute of Architects.
§ 242.45 - Early commencement of work.
(a) Site preparation. Prior to or following the submission of an application, the mortgagor may request for good cause the commencement of certain limited site preparation for the project within legal guidelines and state law. Such work can commence only after the review of the work and concurrence by HUD, including the environmental review under 24 CFR 242.79, previous participation review, and the agreement to certain conditions by the applicant. HUD will not approve such request until it has completed the environmental review under 24 CFR 242.79. The work must meet all requirements and guidelines as if it were approved for mortgage insurance and is to be accomplished at the sole risk of the mortgagor.
(b) Construction completed prior to application. Structures completed more than 2 years prior to application are eligible to be refinanced with insured mortgage proceeds.
(c) Pre-commitment work. Subsequent to submission of an application but prior to the issuance of a commitment or denial by HUD, the hospital and lender may request for good cause the commencement of certain necessary early site work and limited construction activity in connection with the improvements, within legal guidelines and state law. This work must be requested by both the hospital and the lender to be approved. Such work may be eligible to be financed with insured mortgage proceeds if the application is approved and the work complies with all specified conditions of HUD as set forth in a written agreement between the hospital and HUD. It is understood that in some cases the application submitted in order for pre-commitment work to begin may not be complete in all respects. However, at a minimum, the application shall include the approved FHA application form, the application fee (based on the amount of the total proposed insured loan), the inspection fee (based on the cost of the pre-commitment work), a project description of the pre-commitment work and its relation to the total project, and plans and specifications for the proposed pre-commitment work in sufficient detail to allow HUD to conduct its architectural and engineering review and obtain the necessary previous participation information and evidence of compliance with federal and state environmental regulations. Such work can commence only after the review of the work and concurrence by the lender and HUD, including previous participation review. HUD will not approve such request until it has completed the environmental review under 24 CFR 242.79. The work must meet all requirements and guidelines as if it were approved for mortgage insurance and is to be accomplished at the sole risk of the hospital. A request shall be accompanied by documentation required by HUD. That documentation shall include:
(1) A justification explaining the urgent and compelling circumstances that make it necessary to begin construction without waiting for the application process to run its course. The justification must specify the harm the hospital would suffer from waiting.
(2) A plan detailing how the hospital will finance the limited construction if the application for mortgage insurance is denied.
(3) A statement that financing the limited construction by means other than a HUD-insured mortgage in the event the application is denied will impose no significant financial hardship on the hospital. The statement shall be accompanied by supporting historical and projected financial data.
(4) A statement that the hospital recognizes that HUD's agreement to include the cost of the limited construction in a subsequently approved application does not in any way indicate that the application will be approved.
(5) A resolution of the governing body (or, at HUD's discretion, the executive committee of the governing body) of the mortgagor attesting to paragraphs (c)(1) through (4).
(d) Early Start. Subsequent to the issuance of a commitment, if the hospital and lender request the commencement of the project, the work may commence after the review and approval of the request by HUD, including the agreement by the hospital and the lender to any conditions that HUD may require. Any work undertaken prior to the initial endorsement shall be at the sole risk of the hospital.
(e) Prepayment of inspection fee. The hospital shall pay a non-refundable inspection fee to HUD before the work described in paragraph (c) or (d) of this section commences. The fee shall be based on the amount of the pre-commitment and/or early start work requested to be included in the insured mortgage loan.
(f) No expressed or implied intent. Approval to proceed under paragraphs (c) or (d) of this section shall in no way be construed as indicating any intent, expressed or implied, on the part of HUD to approve, disapprove, or make any undertaking or promise whatsoever with respect to the application or with respect to any commitment for mortgage insurance. Any work under paragraphs (c) or (d) of this section shall be undertaken at the sole risk and responsibility of the hospital.
§ 242.46 - Insured advances—building loan agreement.
Prior to the initial endorsement of the mortgage for insurance, the mortgagor and mortgagee shall execute a building loan agreement, approved by HUD, setting forth the terms and conditions under which progress payments may be advanced during construction. To be covered by mortgage insurance, or to be included as an eligible cost, each progress payment involving mortgage proceeds and the owner's equity requirement shall be approved by HUD.
§ 242.47 - Insured advances for building components stored off-site.
(a) Building components. In insured advances for building components stored off-site, the term building component shall mean any manufactured or pre-assembled part of a structure that HUD has specifically identified for incorporation into the property and has designated for off-site storage because it is of such size or weight that:
(1) Storage of the number of components required for timely construction progress at the construction site is impractical, or
(2) Weather damage or other adverse conditions prevailing at the construction site would make storage at the site impractical or unduly costly.
(b) Storage. (1) An insured advance may be made for up to 90 percent of the invoice value (to exclude costs of transportation and storage) of the building components stored off-site, if the components are stored at a location approved by the mortgagee and HUD.
(2) Each building component shall be adequately marked so as to be readily identifiable in the inventory of the off-site location. Each component shall be kept together with all other building components of the same manufacturer intended for use in the same project for which insured advances have been made and separate and apart from similar units not for use in the project.
(3) Storage costs, if any, shall be borne by the contractor.
(c) Responsibility for transportation, storage, and insurance of off-site building components. The general contractor of the insured mortgaged property shall have the responsibility for:
(1) Insuring the components in the name of the mortgagor while in transit and storage; and
(2) Delivering or contracting for the delivery of the components to the storage area and to the construction site, including payment of freight.
(d) Advances. (1) Before an advance for a building component stored off-site is insured:
(i) The mortgagor shall:
(A) Obtain a bill of sale for the component;
(B) Give the mortgagee a security agreement; and
(C) File a financing statement in accordance with the Uniform Commercial Code; and
(ii) The mortgagee shall warrant to HUD that the security instruments are a first lien on the building components covered by the instruments except for such other liens or encumbrances as may be approved by HUD.
(2) Before each advance for building components stored off-site is insured, the mortgagor's architect shall certify to HUD that the components, in their intended use, comply with HUD-approved contract plans and specifications. Under those circumstances permitted by HUD in which there is no architect, compliance with the HUD-approved contract plans and specifications shall be determined by HUD.
(3) Advances may be made only for components stored off-site in a quantity required to permit uninterrupted installation at the site.
(4) At no time shall the invoice value of building components being stored off-site, for which advances have been HUD insured, represent more than 50 percent of the total estimated construction costs for the insured mortgaged project as specified in the construction contract. Notwithstanding the preceding sentence and other regulatory requirements that set bonding requirements, the percentage of total estimated construction costs insured by advances under this section may exceed 25 percent but not 50 percent if the mortgagor furnishes assurance of completion in the form of a corporate surety bond for the payment and performance each in the amount of 100 percent of the amount of the construction contract. In no event will insurance of advances for components stored off-site be made in the absence of a payment and a performance bond.
(5) No single advance that is to be insured shall be in an amount less than $10,000.
§ 242.48 -
The Commissioner may allow advances for certain pieces of equipment or other construction materials for which a manufacturer, fabricator, or other source requires an interim payment(s) in order to assure the timely manufacture or fabrication and delivery to the project site. Such advances can be made only if a bill of sale or an invoice describes the material or equipment and its completion and delivery dates in no uncertain terms, and that such displayed timetable is necessary to meet the requirements of the overall construction schedule cited in the construction contract.
§ 242.49 - Funds and finances: deposits and letters of credit.
(a) Deposits. Where HUD requires the mortgagor to make a deposit of cash or securities, such deposit shall be with the mortgagee or a depository acceptable to the mortgagee and HUD. Any such deposit shall be held in a separate account for and on behalf of the mortgagor, and shall be the responsibility of that mortgagee or depository.
(b) Letter of credit. Where the use of a letter of credit is acceptable to HUD in lieu of a deposit of cash or securities, the letter of credit shall be issued to the mortgagee by a banking institution acceptable to the lender. The mortgagee shall be responsible to HUD for collection under the letter of credit. In the event a demand for payment thereunder is not immediately met, the mortgagee shall forthwith provide a cash deposit equivalent to the undrawn balance of the letter of credit.
(c) Mortgagee not issuer. The mortgagee of record may not be the issuer of the letter of credit without the prior written consent of HUD.
[72 FR 67546, Nov. 28, 2007, as amended at 78 FR 8343, Feb. 5, 2013]
§ 242.50 - Funds and finances: off-site utilities and streets.
The Commissioner shall require assurance of completion of off-site public utilities and streets in all cases, except where a municipality or other public body has by agreement acceptable to HUD agreed to install such utilities and streets without cost to the mortgagor. Where such assurance is required, it shall be in the form of a cash escrow deposit, a letter of credit, the retention of a specified amount of mortgage proceeds by the mortgagee, or a combination thereof. In any case, the amount of deposit or retained cash (or both) must be sufficient to cover the cost of off-site utilities and streets. If a cash escrow is used, it shall be deposited with the mortgagee or with an acceptable trustee or escrow agent designated by the mortgagee. If mortgage proceeds are used, the mortgagee shall retain under terms approved by HUD, rather than disburse at the initial closing of the mortgage, a sufficient portion of the mortgage proceeds allocated to land in the project analysis. As additional assurance, HUD may also require a surety company bond or bonds.
[72 FR 67546, Nov. 28, 2007, as amended at 73 FR 35923, June 25, 2008]
§ 242.51 - Funds and finances: Insured advances and assurance of completion.
(a) Where the estimated cost of construction or substantial rehabilitation is more than $500,000, the mortgagor shall furnish assurance of completion in the form of corporate surety bonds for payment and performance, each in the minimum amount of 100 percent of the construction contract (or Guaranteed Maximum Price, in the case of construction management) and each satisfactory to HUD.
(b) All types of assurance of completion shall be on forms approved by HUD. All surety companies executing a bond and all parties executing a personal indemnity agreement must be satisfactory to HUD.
(c) A mortgagee may prescribe more stringent requirements for assurance of completion than the minimum requirements provided for in this section.
§ 242.52 - Construction contracts.
(a) Awarding of contract. A contract for the construction or substantial rehabilitation of a hospital shall be entered into by a mortgagor, with a builder selected by a competitive bidding procedure acceptable to HUD.
(b) Form of contract. The construction contract shall be: A lump sum form providing for payment of a specified amount; a construction management contract with a guaranteed maximum price, the final costs of which are subject to a certification acceptable to HUD; a design-build contract with terms and certification requirements acceptable to HUD; or such other form of contract as may be acceptable to HUD.
(c) Competitive bidding. A competitive bidding procedure acceptable to HUD must be used in the selection of bidders to perform work or otherwise provide service to the project, the costs of which are included in any form of construction contract cited in paragraph (b) of this section. Fixed equipment not included in the construction contract, and movable equipment, may be purchased by securing quotations or by using competitive bidding procedures.
[72 FR 67546, Nov. 28, 2007, as amended at 73 FR 35923, June 25, 2008]
§ 242.53 - Excluded contractors.
(a) Contracts relating to the construction of the project shall not be made with any person or entity that has been excluded from participation in federal programs, including but not limited to: A general contractor, a subcontractor, or construction manager (or any firm, corporation, partnership, or association in which such contractor, subcontractor, or construction manager has a substantial interest). Before entering into contracts with any such person or entity, owners must consult the government-wide list of excluded parties, and any list of excluded parties maintained by HUD.
(b) Contracts relating to the construction of the project shall not be made with a general contractor that has an identity of interest, as defined by HUD, with the mortgagor or mortgagee.
(c) If HUD determines that a contract has been made contrary to the requirements of paragraphs (a) or (b) of this section and so notifies the mortgagee, HUD will require the contractor or construction manager to cost-certify and may require other remedial action in addition to taking enforcement action, as HUD deems appropriate.
source: 72 FR 67546, Nov. 28, 2007, unless otherwise noted.
cite as: 24 CFR 242.46