This part applies to discharges of process wastewater resulting from the slaughtering of poultry, further processing of poultry and rendering of material derived from slaughtered poultry. Process wastewater includes water from animal holding areas at these facilities.
For the purpose of this subpart: Poultry first processing means slaughtering of poultry and producing whole, halved, quarter or smaller meat cuts.
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart that slaughters more than 100 million pounds per year (in units of LWK) must achieve the following effluent limitations representing the application of BPT:
Effluent Limitations
[BPT]
Regulated
parameter
| Maximum daily
1
| Maximum monthly avg.
1
|
---|
Ammonia (as N) | 8.0 | 4.0
|
BOD5 | 26 | 16
|
Fecal Coliform | (
2) | (
3)
|
O&G (as HEM) | 14 | 8.0
|
TSS | 30 | 20
|
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart that slaughters more than 100 million pounds per year (in units of LWK) must achieve the following effluent limitations representing the application of BAT:
Effluent Limitations
[BAT]
Regulated
parameter
| Maximum daily
1
| Maximum monthly avg.
1
|
---|
Ammonia (as N) | 8.0 | 4.0
|
Total Nitrogen | 147 | 103
|
Any source that is a new source subject to this subpart must achieve the following performance standards:
(a) Facilities that slaughter no more than 100 million pounds per year (in units of LWK) must achieve the following performance standards:
Performance Standards
[NSPS]
Regulated
parameter
| Maximum daily
1
| Maximum monthly avg.
1
|
---|
Ammonia (as N) | 8.0 | 4.0
|
BOD5 | 26 | 16
|
Fecal Coliform | (
2 ) | (
3 )
|
O&G (as HEM) | 14 | 8.0
|
TSS | 30 | 20
|
(b) Facilities that slaughter more than 100 million pounds per year (in units of LWK) must achieve the following performance standards:
Performance Standards
[NSPS]
Regulated
parameter
| Maximum daily
1
| Maximum monthly avg.
1
|
---|
Ammonia (as N) | 8.0 | 4.0
|
BOD5 | 26 | 16
|
Fecal Coliform | (
2) | (
3)
|
O&G (as HEM) | 14 | 8.0
|
TSS | 30 | 20
|
Total Nitrogen | 147 | 103
|
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the application of BCT: Limitations for BOD5, TSS, O&G (as HEM), and fecal coliform are the same as the corresponding limitation specified in § 432.112.