Any source that is a new source subject to this subpart must achieve the following performance standards:
(a) Facilities that further process no more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:
Performance Standards
[NSPS]
Regulated
parameter
| Maximum daily
1
| Maximum monthly avg.
1
|
---|
Ammonia (as N) | 8.0 | 4.0
|
BOD5 | 26 | 16
|
Fecal Coliform | (
2) | (
3)
|
O&G (as HEM) | 14 | 8.0
|
TSS | 30 | 20
|
(b) Facilities that further process more than 7 million pounds per year (in units of finished product) must achieve the following performance standards:
Effluent Limitations
[NSPS]
Regulated
parameter
| Maximum daily
1
| Maximum monthly avg.
1
|
---|
Ammonia (as N) | 8.0 | 4.0
|
BOD5 | 26 | 16
|
Fecal Coliform | (
2) | (
3)
|
O&G (as HEM) | 14 | 8.0
|
TSS | 30 | 20
|
Total Nitrogen | 147 | 103
|